background image

15 

 

Table 5: Parts list, S

UPREME

 Comfort PSC 

Item 

Description 

Comments 

B04431 

Acoustic insulation 

  

B04343-03 

Left side panel assembly 

Left panel, items 3 and 1 included 

B04340-02 

Left side panel insulation 

  

B04344-01 

Back panel assembly 

  

B04341 

Top back panel insulation 

  

B04343-01 

Right side panel assembly 

Right panel, items 7 and 1 included 

B04340-01 

Right side panel insulation 

  

B04302-02 

Top front panel 

  

L01J006 

Breaker 60 A 

  

10 

B04310 

Breakers support  

  

11 

B04368 

Sequencer card assembly 

Card and plastic pins 

12 

B04311 

Components support 

  

13 

L01J001 

Breaker 15 A 

  

14 

B04000-03 

Modified 12 positions terminal 

  

15 

X02330 

Label "Terminal Supreme C/A" 

  

16 

B04288 

Electrical sequencer kit 

Supreme 18/20 kW 

17 

B04289 

Electrical sequencer kit 

Supreme 15 kW 

18 

B04290 

Electrical sequencer kit 

Supreme 10 kW 

19 

B04365 

Door assembly 

  

20 

B04356-01 

Blower assembly 1/3hp (120V-PSC) 

Supreme 10/15/18/20 kW 

21 

B04356-02 

Blower assembly 1/3hp (240V-PSC) 

Supreme 10/15/18/20 kW 

22 

B04356-03 

Blower assembly 1hp (120V-PSC) 

Supreme 20 kW 

23 

B04356-04 

Blower assembly 1hp (240V-PSC) 

Supreme 20 kW 

24 

Z01I036 

Blower 112-9R 

Supreme 20 kW 

25 

Z01I035 

Blower 112-8R 

Supreme 10/15/18/20 kW 

26 

B01889 

Motor support band and legs 

  

27 

L06K004 

Motor 1hp (120v-PSC) 

Supreme 20/ kW 

28 

L06K005 

Motor 1hp (240v-PSC) 

Supreme 20 kW 

29 

L06G007 

Motor 1/3hp (120v-PSC) 

Supreme 10/15/18/20 kW 

30 

L06G015 

Motor 1/3hp (240v-PSC) 

Supreme 10/15/18/20 kW 

31 

B04287 

Electrical blower kit 

  

32 

L01I001 

Capacitor 5 uF 

Supreme (120 PSC) 10/15/18/20 kW 

33 

L01I003 

Capacitor 10 uF 

Supreme (240 PSC) 10/15/18/20 kW 

34 

L01I005 

Capacitor 15 uF 

Supreme (120 PSC-1 hp) 20 kW 

35 

B01024 

Capacitor support 

  

36 

B04303 

Floor 

  

37 

B04309 

Fan slide 

  

38 

B04304 

Fan separator 

  

39 

B03299-02 

Filter holder tip 

 

40 

B03298-02 

Filter support outline 

 

41 

R02N028 

Hi-limit 125+/-5.5C 

  

42 

B04308 

Hi-limit deflector 

  

43 

B04305 

Front separator 

  

44 

L01H030 

Relay DPST 22 VDC 

  

45 

B04369 

Electrical power kit 

Supreme 10 @ 20kW 

46 

L01H009 

Relay 24 VAC 

  

47 

B04351-02 

Element assembly 

5 kW 

48 

B04351-01 

Element assembly 

4 kW 

49 

B04315-01 

Element plate 

  

50 

L01F010 

Transformer 208/240/24 

  

51 

L99F007 

Terminal bloc 600V/175A (1423570) 

  

52 

B04359 

Blower grill 

  

53 

B04306 

Deflector 

  

54 

B04307 

Element support 

  

  

  

Accessories 

DFB-SUP 

Downflow base 

(ref: B03310-03) 

 

Summary of Contents for Supreme Advantage Series

Page 1: ...AGE PSC MOTOR Caution Do not tamper with the unit or its controls Call a qualified service technician INSTALLER SERVICE TECHNICIAN USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING...

Page 2: ...emperature Rise Test 8 3 4 2 High limit verification 8 4 MAINTENANCE 8 4 1 AIR FILTER 8 4 2 MOTOR LUBRICATION 8 5 FURNACE INFORMATION 9 TABLES Table 1 Supply air adjustment on cooling mode 6 Table 2 T...

Page 3: ...Ask the technician installing your furnace to show and explain to you the following items i The main disconnect switch or circuit breaker ii The air filter and how to change it check monthly and clea...

Page 4: ...uitable ductwork 2 3 1 Upflow installation The return duct may be installed to the back the bottom on the left side or on the right side of the unit The supply duct shall be installed on the top of th...

Page 5: ...e terminal block on models over 25kW the installation must be performed with copper wire ONLY in order to comply with the Canadian electrical code The usage of an aluminum or copper wire is acceptable...

Page 6: ...the vertical sections of the supply and return air duct with soundproofing material c Use baffles in short radius elbows d Use flexible hangers to suspend the ducts A heat pump or an air conditioner c...

Page 7: ...eed adjustments for heating and air conditioning are appropriate and according to the specifications in this manual 4 The thermostat of the room is in heating mode and is set higher than the ambient t...

Page 8: ...not operate above the temperatures specified in the Technical Specifications Table 2 This is particularly important if a cooling coil or a heat pump has been installed in the ducts Hi Limit thermal p...

Page 9: ...er name and address START UP RESULTS Voltage Total current consumed by the elements Supply air temperature Return air temperature Supply air duct static pressure Return air duct static pressure Total...

Page 10: ...x 8 12 x 9 GENERAL INFORMATION 22 x 22 x 36 5 20 x 20 19 x 19 1 20 x 20 3 tons 5 tons Capacity 10 15 18 20 23 25 20 23 25 27 30 Power total 240V 208V Kw 10 7 5 15 11 3 18 13 5 20 15 23 17 3 25 18 8 2...

Page 11: ...al static pressure inche of W C Table 4 Airflow CFM SUPREME with 1HP motor SUPREME equipped with a 1 HP 120V blower motor 0 2 0 3 0 4 0 5 0 6 0 7 0 8 LOW 1 110 1 090 1 085 1 080 1 070 1 050 1 005 MED...

Page 12: ...12 Figure 12 Electrical diagram SUPREME Comfort PSC...

Page 13: ...13 Figure 13 Electrical diagram SUPREME Advantage PSC...

Page 14: ...14 Figure 14 Parts list SUPREME Comfort PSC...

Page 15: ...0 kW 23 B04356 04 Blower assembly 1hp 240V PSC Supreme 20 kW 24 Z01I036 Blower 112 9R Supreme 20 kW 25 Z01I035 Blower 112 8R Supreme 10 15 18 20 kW 26 B01889 Motor support band and legs 27 L06K004 Mot...

Page 16: ...16 Figure 15 Parts list SUPREME Advantage PSC...

Page 17: ...Blower assembly 1 3hp 120v PSC Supreme 10 15 18 20 23 25 kw 31 B04356 02 Blower assembly 1 3hp 240v PSC Supreme 10 15 18 20 23 25 kw 32 B04356 04 Blower assembly 1hp 240v PSC Supreme 20 23 25 27 30 k...

Reviews: