background image

20 

 

Table 5: Parts list 

 

ITEM

DESCRIPTION

PART #

1

Com plete heat exchanger

B30776-01

2

Top heat exchanger

B30542-01

3

Gas ket, heat exchanger 

B30517

4

Hexagonal flange nut 3/8-16NC bras s

F07O001

5

Com bus tion cham ber

B30518

6

Bottom  heat exchanger

B30757

7

Was her 1 7/16 zinc

F06F015

8

Front filter drawer

B30507

9

Gas ket, burner

B30534

10

Left s ide panel as s em bly

B30550-02

11

Left s ide panel ins ulation

B30571

12

Left filter s upport

B30566

13

Rear panel as s em bly

B30549

14

Rear panel ins ulation

B30572

15

Rear filter s upport

B30555

16

Rear Baffle

B30564

17

Divis ion panel

B30567

18

Blower s lide s upport

B30513

19

Right s ide panel as s em bly

B30550-01

20

Right s ide panel ins ulation

B30571

21

Right filter s upport

B30566

22

Upper front reinforcer

B30556

23

Blower door as s em bly

B30709-02

24

Door handle

Z99F050

25

Center front panel as s em bly

B30703

26

Center front panel ins ulation

B30570

27A

Front right baffle

B30569-01

27B

Front left baffle

B30569-02

28

Bottom  front panel as s em bly

B30774

29

Bottom  front panel ins ulation

B30773

30

Was her 3/8" AA zinc

F06F005

31

Hexagonal nut 3/8-16NC bras s

F07F024

32

Sight glas s

Z99F061

33

Hexagonal flange nut 3/8-16NC bras s

F07O001

34A

5" breech plate

B30459

34B

3" breech plate

B30515

35

Gas ket, breech plate 

B30415-02

36

Burner electrical kit

B30575

37

Corner conduit

B30557

38

Electrical box cover ( without logo )

B40098-02

39

Trans form er 120/24 VAC / 40 VA 

L01F009

40

Term inal s trip, 6 pos itions  

A00336

41

Electrical box

B30830

42

Relay SPDT 24VAC

L01H009

43

Rocker s witch SPST

 (constant blower operation)

L07F003

44

Term inal s trip, 6 pos itions  

L05F011

45

Rocker s witch SPST (m ain power)

L07F016

46

Therm os witch 160-40F

R02N012

47

Therm os witch 110-10F

R02N011

48

Blower weel 10X10

Z01L004

49

Blower 100-10T   (hous ing and wheel)

B03720-04

50A

Blower as s em bly (55, 56, 48, 49, 51 and 54 included)

B01405-01

50B

Belly band as s em bly (belly band & legs  included)

B01888

51

Motor as s em bly 1/3 HP (m otor, bell band & legs  included)

B01890-01

52

Blower electrical kit

B30096

53

Blower s ide rails

B30433

54

Seal s trip

B01291-01

55

Capacitor 5 MF 

L01I001

56

Capacitor holder

B01024

57

Fan lim it control 11 1/2"

B04272-02

58

Blocked vent shut off BVSO

Z06G001

59

External electrical kit BVSO

B03118-01

60

Relay SPDT 120VAC

L01H011

 

Summary of Contents for ODH53-F

Page 1: ...MATION IN THIS MANUAL FOR THE INSTALLATION AND SERVICING OF THE FURNACE AND KEEP THE DOCUMENT NEAR THE UNIT FOR FUTURE REFERENCE HOMEOWNER PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR FUTURE REFERENCE...

Page 2: ...D ADJUSTMENTS 11 3 3 1 General 11 3 3 2 Restart after burner failure 11 3 3 3 Combustion chamber curing 11 3 3 4 Smoke CO2 test 11 3 3 5 Perform the supply air temperature rise test 11 3 3 6 Vent temp...

Page 3: ...failure and cause dangerous operating conditions e Visually check all oil line joints for signs of leakage f Connect furnace to a side wall terminal or chimney g The points in Part 2 Operation are vi...

Page 4: ...ossible Open faucets in appropriate areas b Have someone check the structure frequently during cold weather to make sure it is warm enough to prevent pipes from freezing Contact a qualified service ag...

Page 5: ...ide wall power vent The unit will operate at a positive over fire draft and flue draft WARNING Poisonous carbon monoxide gas hazard Never vent this furnace together with another combustion appliance w...

Page 6: ...C 300 F 179 C 355 F 221 C 430 F 41 140 000 1 00 0 1 m 4 0 15 m 6 107 C 225 F 149 C 300 F 185 C 365 F 221 C 430 F 51 175 000 1 25 0 1 m 4 0 15 m 6 116 C 240 F 135 C 275 F 160 C 320 F 185 C 365 F 2 3 AI...

Page 7: ...vapour barrier Comprehensive installation instructions are provided with the kit 2 4 OIL TANKS AND LINES Check your local codes for the installation of the tank and accessories A manual shut off valv...

Page 8: ...tructions supplied with the venting system 2 6 INSTALLING ACCESSORIES WARNING Electrical shock hazard Turn OFF electric power at fuse box or service panel before making any electrical connections and...

Page 9: ...g Failure to properly seal duct can result in death personal injury and or property damage WARNING Poisonous carbon monoxide gas hazard Install evaporator coil on the supply side of the furnace ductin...

Page 10: ...satisfied Also the solenoid valve remains open Thermostat is satisfied 8 Relay contacts open solenoid valve closes and the burner fan motor post purges the combustion chamber and vent for a pre set t...

Page 11: ...after fabrication It is important to clear the chamber of this residue before testing If you smoke test before curing the instrument may become damaged To cure the chamber run the unit for 3 consecut...

Page 12: ...efore a 1 smoke reading occurs 4 If the burner does not shut down before 1 smoke occurs ensure that the burner is set up according to Part 2 section 3 4 2 3 4 Perform the CO2 Smoke Test and allow for...

Page 13: ...amic chambers they are easily damaged Soot will have collected in the first sections of the heat exchangers only if the burner was started after the combustion chamber was flooded with fuel oil or if...

Page 14: ...should be replaced as required Secondary filter The 10 or less micron filter cartridges should be replaced annually 4 2 6 Air filters Air filters are the disposable type They should be replaced at lea...

Page 15: ...Service telephone Day Night Dealer name and address START UP TEST RESULTS Nozzle Pressure lbpsi Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperatur...

Page 16: ...only 3 1 5 3 3 3 4 5 AFUE From CSA B212 standard and Canadian regulation 81 5 81 0 80 3 AFUE From ASHRAE 103 standard and US regulation 81 5 81 0 80 3 RIELLO BURNER SIDE WALL INSTALLATION Burner tube...

Page 17: ...17 Figure 5 Furnace Dimensions...

Page 18: ...18 Figure 6 Electrical Diagram ODH53 F...

Page 19: ...19 Figure 7 Parts List Exploded view B50030 Rev C...

Page 20: ...tion B30773 30 Washer 3 8 AA zinc F06F005 31 Hexagonal nut 3 8 16NC brass F07F024 32 Sight glass Z99F061 33 Hexagonal flange nut 3 8 16NC brass F07O001 34A 5 breech plate B30459 34B 3 breech plate B30...

Reviews: