20
DSCS-9/10
Series
3.0
Maintenance
•
Wiring Diagrams
Figure 3.5
•
Internal Wiring Diagram
Figure 3.6
•
Field Wiring Diagram
Starting Amp Draw:
0.12A
Running Amp Draw:
0.08A
Field Wiring:
1
Maintain electrical polarity when hooking up multiple heaters.
2
Allow heaters to be switched by zones for heating flexibility.
230 VAC
SWITCH OR TIMER
OPTIONAL
SWITCH OR TIMER
L1
230 VAC
L2
IGNITION
MODULE
ELECTRODE
ASSEMBLY
GAS VALVE
230VAC DSI MODULE
O PR
GY
BK
BL
G/Y
BR
L2
L1
W
BR
BK
BL
G/Y
G/Y
BR
BL
G/Y