IF SPACER
IS USED
DOOR
THICKNESS
+ 3/8” MIN
+9/16” MAX
Position A
Position B
Butterfly cam
Set Screw
Retaining
Plate
LHRB SHOWN
Fig. 2
Fig. 3
Fig. 1
Preparing the ECL-620 for installation
1. Assemble the rim cylinder (not included) through the
escutcheon and the cylinder retaining bracket as
shown in
Fig 1
. Add cylinder spacer or cut the tailpiece
as shown.
2. *See page 1 for handing illustrations*
The lever trim as received is handed for LHRB
(Left Hand Reverse Bevel) doors. If your door is LHRB,
proceed directly to step 3. If the door is a RHRB, then the
lever needs to be reversed and the input extension needs
to be moved from position A to position B.
(See
Fig 2
).
To do so:
-Remove the lever input extension from position A by first
loosening its' setscrew. (See Fig 3)
-Remove, likewise, the short locking collar at position B and
discard it.
-Remove screw and discard the retaining plate, screw and
the
loose
parts under the retaining plate.
-Remove lever from collar and rotate the lever 180°. Reinstall
it through the butterfly cam. Secure the lever by tapping down
the lever input extension taken from position A, onto the
square shaft of the lever and tighten the set screw. When
installed, the free end of the lever will point toward the hinged
side of the door, not the strike.
The outside lever trim is now completely assembled.
LHRB
RHRB
INS-620/PM Page 3