                         Symptom:

Key cylinder is loose or sticks out.

Does not arm, key requires high effort to rotate.

Unit in constant alarm mode.

Turning key CCW does not reset alarm.

Unit goes into alarm when service requires

opening the front cover.

Not enough bypass time when set at max.

Goes into alarm when trying to set time.

Unit does not reset once in alarm mode.

Unit chirps every 20 to 30 seconds.

This is a low battery indication.

                                             Probable cause / Fix

Tapered collar not installed.

Hex nut is not secure.

103970 bracket not installed or installed backwards (Flange goes towards the cover).

Incorrect cam on mortise cylinder. Should be Yale type cam.

Self adjusting switch cam mounting screws overly tight.

Magnetic switch too far from magnet or connected to the wrong terminals on the

PWA.

Wrong type of switch contact. Must be closed contact with the door closed and

magnet in correct position.

Pull tamper switch plunger fully out, turn key CCW. Make sure door is closed during

initial opening of the cover.

Change switch positions as needed. See label on inside front cover for options.

Turn key CCW and release. Then press the 'Activate Timed By-Pass'  button.

Make sure door is fully closed.

Make sure wiring to the magnetic switch is not damaged or cut.

Check AC power to the device, and that building power is present at the outlet.

Make sure optional plug-in transformer is plugged in and the holding screw installed.

Check for damaged wiring between the transformer and the EAX-3500.

The battery should be replaced every three years

EAX-3500 Troubleshooting

6) 

TO ACTIVATE TIMED BYPASS:

Rotate key counterclockwise (CCW) until light bar meter flashes, release key.

To add By-Pass time press 'ACTIVATE TIMED BY-PASS' button. Light bar illuminates gradually as more By-Pass time is added.

Release button. Single green LED turns ON indicating By-Pass time is set.

Remove key and prop door open.

NOTE: Alarm automatically arms and resets if door closes before time expires.

7) 

ADD ADDITIONAL TIMED BYPASS:

Insert key and rotate CCW single green LED turns.

Release key

Press 'ACTIVATE TIMED BY-PASS' button. Light bar illuminates gradually as more By-Pass time is added.

Note:

  If By-Pass time expires while door is open, alarm will sound.

TO SILENCE ALARM:

 Close door, insert and rotate key CCW.

8) To service device pull plunger on tamper switch as shown in Detail C.  Rotate access control key CCW.

103140   Page 5

Summary of Contents for EAX-3500

Page 1: ...ght bar meter illuminates gradually as more By Pass time is added NOTE If By Pass time expires while door is open alarm will sound TO SILENCE ALARM Close door insert and rotate key CCW TO ACTIVATE TIMED BY PASS 1 Rotate key counterclockwise CCW light bar meter flashes then release key 2 To add By Pass time press ACTIVATE TIMED BY PASS button Light bar illuminates gradually as more bypass time is a...

Page 2: ... 10 x 1 10 x 1 PPH PPH Tools Required Pencil Metal Applications All other Applications Drill Bit Fastener Table Comments w Anchors EAX 3500 Installation and Usage Guide Display Board p n 103943 Cover Lock Key 102966 Bracket p n 103970 p n 100783 Cam Assembly p n 102680 p n 102627 15 2 pls Battery Strap p n 103963 Modular Cable p n 104017 5 12V Battery p n 103952 Power Supply Board p n 103941 Tampe...

Page 3: ...nt MS2049S Option connections Magnetic switch White Red NOT Used Black Magnetic Switch Surface Mount DISPLAY BOARD POWER BOARD 2 MAGNETIC SWITCH INSTALLATION Install magnetic contact switch onto door using magnetic switch instructions For wire requirements see Manufacture s Recommendation Chart Route wires to Exit Alarm location Magnetic Contact Switch Within 6 feet 2 conductor cable 22AWG 20 feet...

Page 4: ...onnect power wires to the two place terminal block located on lower left corner of power board Wires are not polarity sensitive Fig 3 By Pass time is factory set for 5 minutes See detail B above for additional By Pass time options To By Pass for service extend plunger on tamper switch See DETAIL C Insert access control key into mortise cylinder on front side of hinged panel Install battery supplie...

Page 5: ... release Then press the Activate Timed By Pass button Make sure door is fully closed Make sure wiring to the magnetic switch is not damaged or cut Check AC power to the device and that building power is present at the outlet Make sure optional plug in transformer is plugged in and the holding screw installed Check for damaged wiring between the transformer and the EAX 3500 The battery should be re...

Reviews: