RHR
LHR
CL
*DOOR
HEIGHT
*OPENING
HEIGHT
Measure per figure below:
*
These dimensions will be needed during rod length adjustment. Measure door before removing.
*TOP GAP 1/8" (Standard)
*BOTTOM GAP (Max 1-1/2")
*THRESHOLD HEIGHT (if used)
*DIMENSION "A"
(40" RECOMMENDED)
DEVICE
HORIZONTAL
Top Gap
Opening Height
Dimension table
Dimension name
Door Height
Dimension "A"
Threshold Height
Dimension value
(fill in)
Bottom Gap
!!!CHECK BEFORE STARTING!!!
NOTE
: LOCAL CODES MAY REQUIRE THROUGH BOLTING. SEX NUTS ARE
NOT
INCLUDED WITH THIS DEVICE. SEX NUTS CAN BE PURCHASED SEPARATELY.
104885 Page 5
STEP 1:
DOOR / OPENING MEASUREMENTS
RHR DOOR
INSIDE FACE
LHR DOOR
INSIDE FACE
FINISHED
FLOOR
FINISHED
FLOOR
X
Door Must Swing Freely
Door Must Not be Warped
Door Must Not Bind
Door Must Not Sag
Door Skin
Reinforcement
X
X
X
Blind Rivet Nut
Doors and frames with walls having a structural thickness (metal
skin plus reinforcement) to engage less than (3) full screw
threads, are considered unreinforced for hardware.
Unreinforced Doors: Use Sex Nuts and Bolts
Unreinforced Frames: Use Blind Rivet Nuts (see sketch).
Fasteners for unreinforced openings are not supplied by Detex.
Reinforced door or
frame engages at
least (3) screw
threads.
Minimum Stile Width: 3-1/2"