background image

    Page 6                                               Copyright © 1995-97 Detection Systems, Inc.                   DS1520/30 Installation Instructions

•  Mounting

-  Remove the cover.
-  Remove the PC board.
-  Mount the backplate to the desired lo-

cation.

-  Replace the PC board.
-  Route the wiring to the PC board.
-  Secure the wire to the VS A10 with a

tie-wrap.

-  Wire the system as necessary.
-  Test the system for proper functionality.
-  Replace the cover.

5.1.9 Using the Cable Inlets

The detector is shipped with a cable inlet designed to ac-
cept only one cable. Three additional cable inlets are avail-
able for different applications.

•  The VS A11. This cable inlet is designed to accept

square conduit. To use this, the detector must be
mounted on a VS A1 mounting plate.

•  The VS A12. This cable inlet is designed to accept

round conduit. The diameter of the opening is 3/4 of
an inch for use with 1/2  inch EMT.

.

•  The VS A13. This cable inlet is designed to accept two

flexible stainless steel conduits. It also provides a knock-
out for a third cable.

6.0  Wiring

6.0.1  Wiring the Detectors

Bring the cable(s) to the detector. Feed them through the cable inlet and cut
them leaving 4 inches of cable after the strain relief.
Wire the terminals according to the following diagram. Fold the excess wire
inside the wiring area of the detector.

1

2

3

4

5

6

7

8

+

LED

Alar m

Tamper

Inp ut Po wer L ED

Al arm Ou tp ut

Tampe r Swi tch

Form "C"

re lay con ta ct

N ormal ly

Clo sed

Power

Relay contacts shown with power on,

no alarm and tamper switch closed

6.0.2  Wiring the VS A6 Movable Mounting Kit

The movable mounting kit has a two terminal T-strip. It includes a microswitch
and a reed switch. They both are supervising whether the detector is in the
Day or Night position.

The alarm loop should be connected in-series with both VS A6 switches so
that the system can not be armed if the detector is in the Day position.

When using the VS A14 Test Transmitter, the terminal block of the Movable
Mounting Plate may be used to power the Test Transmitter.

•  Wiring

1+ 2 -

3

4

5

6

7

8

LE D

Al arm

Ta mp er

P ow er

EOL

Test

Alarm

Loop

Power

+

-

Ground

VS A6

VS A10

VS A14

+

-

DS1520

DS1530

Tamper

Loop

- If using an end of line resistor (EOL), use terminal 6 of the detector to

put the resistor in-series with the alarm relay.

- To put both of the Movable Mounting Plate's switches in-series, con-

nect the wire from the microswitch to terminal 4 of the detector.

- Connect the alarm loop from the Junction Box to the center terminal of

the VS A6 and to terminal six of the detector (if not using an EOL,
connect it directly to terminal five).

6.0.3  Wiring the VS A7 Keyhole Protection Kit

The Keyhole Protection Mounting Plate contains a microswitch that super-
vises the position of the lever.

The alarm loop should be wired in-series with the microswitch.

When the lever covers the keyhole, the microswitch is closed and the sys-
tem can be armed.

If using an EOL, wire it to terminal six of the detector to connect it in-series
with the alarm relay and the microswitch.

1 + 2-

3

4

5

6

7

8

L ED

Al arm

Tampe r

Power

EOL

Test

Alarm

Loop

Power

+

-

Ground

VS A10

VS A14

+

-

DS1520

DS1530

VS A7

Tamper

Loop

Summary of Contents for DS1520

Page 1: ...eate mechanical vibra tions in the protected structure This includes but is not limited to Electric Motors Transformers Fans Air Conditioners Water Pipes Ultrasound Detectors Bells Human Activity may...

Page 2: ...ultiple Detectors If mounting inside the body mount a detector on a space which is clear and easily accessible e g the ceiling Also mount a detector on the inside of a door close to the hinges It is a...

Page 3: ...ce away from the mounting surface A A A B C A Holes for mounting the detector B Hole for mounting the plate to the concrete expansion plug C Hole for marking the mounting hole for the VS A14 if used A...

Page 4: ...the Junction Box and Day plate together on the side of the safe vault or a nearby wall so that cable will prevent the safe vault door from opening when the detector is moved to the Night plate Mount...

Page 5: ...mbly inside the box 6 1 5 Surface Mounting with the VS A3 The VS A3 is a box designed to protect the detector from damage and excess humidity A A A B C Place rubber gasket between the box and the cove...

Page 6: ...switch closed 6 0 2 Wiring the VS A6 Movable Mounting Kit The movable mounting kit has a two terminal T strip It includes a microswitch and a reed switch They both are supervising whether the detecto...

Page 7: ...Transmitter The Test Transmitter is mounted inside the detector It is activated by sup plying it with 12 volts Upon activation it will transmit signals that will alarm the detector Mount the test tran...

Page 8: ...nces Scratch on protected surface with a screwdriver Disturbance of detector from outside Cover detector with a sound absorbing material no Poor mechanical coupling with surface tighten mounting screw...

Reviews: