4. Self test error code display
The detector automatically performs a self test after powered on. If one of the following codes is showed on the display window, it is
probable that the sensor is blocked by banknotes or dust. Please use a brush or a piece of soft cloth to clean the dust on the sensor or
remove the blocking banknote. Once complete, restart the machine.
5. Error codes display
If the following error code is showed on the display window during the course of detecting, you can handle them as per the error type
when the machine is stopped.
Error Code
Reason
C1
The code disc or motor is abnormal.
C2
The feeding sensor is abnormal.
C3
The left IR penetrating sensor is abnormal.
C4
The right IR penetrating sensor is abnormal.
C5
The bottom left IR reflection is abnormal.
C6
The bottom right IR reflection is abnormal.
C7
The upper left IR reflection is abnormal.
C8
The upper right left IR reflection is abnormal.
C9
The 850nm IR reflection is abnormal.
C10
The 960nm IR reflection is abnormal.
C11
The left MG sensor is abnormal.
C12
The right MG sensor is abnormal.
Error Code
Reason
E1
Banknote length error.
E2/E3
Magnetic ink properties error.
E4/E5
Infrared properties error.
E6
Banknote thickness error / Double note error.
E7
Slant note (note not inserted straight).
E10
Banknote retreat abnormal.
E11/E15/E16/E17
Infrared image abnormal.
E13
Banknote without magnetic.
E14
Magnetic feature abnormal.