background image

Deta Electrical Co. Ltd.   Kingsway House  

 

Laporte way 

Luton   Bedfordshire   LU4 8RJ 

Tel.: +44 (0)1582 544 544    Technical Helpline: +44 (0)1582 544 548 

 

 

 

O03 

NPD 0526 0516 V3 

LED Flood light

 

 

 
 
 

  

 

 

Power Supply 

220 - 240V   50Hz 

Lamp Colour Temperature 

6000k 

Lamp Type 

LED 

IP Rating 

IP Rating - PIR 

IP65 
IP44 

Driver 

Integral 

PIR Detection Range & Angle 

8 – 10 meters @ 180° 

To be read in full before installation and kept for future reference 

Safety Instructions 

 

Ensure the power supply is switched off before fitting, servicing. 

 

This floodlight is for outdoor use only. 

 

This floodlight must be mounted on a non-flammable surface. 

 

Ensure adequate ventilation is allowed between the floodlight and any object 
above, in front or to either side. Minimum distance: 0.5m above, 0.3m to either 
side and 1.0m in front. 

 

The floodlight can become hot during use. Allow adequate cooling time before 
handling. 

 

This floodlight is of Class I construction and must be earthed. 

 

This floodlight must be installed in accordance with the current edition of the 
IEE Wiring Regulations. 

If in doubt, contact a qualified electrician. 

Maintenance Instructions 

 

There are no user serviceable parts in this fitting. 

 

Periodically wipe the housing and heat sinks to maintain proper heat 
dissipation. 

PIR Controls 

On the base of the PIR are dials: 

 

Sensitivity Control – When the control has been rotated fully anti-clockwise, the 
PIR detector will operate at a distance of about 1m. When rotated fully 
clockwise, the PIR detector will operate at the maximum distance of about 10m. 
The operating range can be adjusted to suit requirements. 

 

Time Control – Turn the dial fully anti-clockwise, the flood lights will stay on for 
5secs. Turn the dial fully clockwise, the flood light will stay on for 7mins. 

 

Daylight / Lux Control – Provisionally turn the control fully to the Moon symbol. 
In this setting the PIR is inactive during daylight. At dusk, when the light level is 
at the desired level, adjust the dial towards the Sun symbol until the Flood Light 
turns on. 

 

Manual override – To override the PIR so that the floodlight stay on constantly, 
turn the power to the flood light off and immediately back on. The flood light 
will flash and then stay on constantly. To return control to the PIR, turn the 
power to the floodlight of for at least 10 second and then back on again. 

L2332BK6A 

10W LED Flood Light 

L2333BK6A 

10W LED Flood Light with PIR 

L2336BK6A 

30W LED Flood Light 

L2337BK6A 

30W LED Flood Light with PIR 

 

Installation Instructions 

 

Remove mounting bracket, and use as a template to mark fixing holes.

 

 

Secure bracket in location.

 

 

Wire the pre-wired floodlight directly to an IP connector or connection box 
ensuring correct polarity is observed. Brown – Live, Blue – Neutral, 
Green/yellow - Earth. 

 

Offer the fitting back to the mounting bracket and replace the bolts.  Adjust the 
fitting to the required angle before tightening the bolts.

 

Reviews: