Deta Electrical Co. Ltd. Kingsway House
Laporte way
Luton Bedfordshire LU4 8RJ
Tel.: +44 (0)1582 544 544 Technical Helpline: +44 (0)1582 544 548
O03
NPD 0526 0516 V3
LED Flood light
Power Supply
220 - 240V 50Hz
Lamp Colour Temperature
6000k
Lamp Type
LED
IP Rating
IP Rating - PIR
IP65
IP44
Driver
Integral
PIR Detection Range & Angle
8 – 10 meters @ 180°
To be read in full before installation and kept for future reference
Safety Instructions
Ensure the power supply is switched off before fitting, servicing.
This floodlight is for outdoor use only.
This floodlight must be mounted on a non-flammable surface.
Ensure adequate ventilation is allowed between the floodlight and any object
above, in front or to either side. Minimum distance: 0.5m above, 0.3m to either
side and 1.0m in front.
The floodlight can become hot during use. Allow adequate cooling time before
handling.
This floodlight is of Class I construction and must be earthed.
This floodlight must be installed in accordance with the current edition of the
IEE Wiring Regulations.
If in doubt, contact a qualified electrician.
Maintenance Instructions
There are no user serviceable parts in this fitting.
Periodically wipe the housing and heat sinks to maintain proper heat
dissipation.
PIR Controls
On the base of the PIR are dials:
Sensitivity Control – When the control has been rotated fully anti-clockwise, the
PIR detector will operate at a distance of about 1m. When rotated fully
clockwise, the PIR detector will operate at the maximum distance of about 10m.
The operating range can be adjusted to suit requirements.
Time Control – Turn the dial fully anti-clockwise, the flood lights will stay on for
5secs. Turn the dial fully clockwise, the flood light will stay on for 7mins.
Daylight / Lux Control – Provisionally turn the control fully to the Moon symbol.
In this setting the PIR is inactive during daylight. At dusk, when the light level is
at the desired level, adjust the dial towards the Sun symbol until the Flood Light
turns on.
Manual override – To override the PIR so that the floodlight stay on constantly,
turn the power to the flood light off and immediately back on. The flood light
will flash and then stay on constantly. To return control to the PIR, turn the
power to the floodlight of for at least 10 second and then back on again.
L2332BK6A
10W LED Flood Light
L2333BK6A
10W LED Flood Light with PIR
L2336BK6A
30W LED Flood Light
L2337BK6A
30W LED Flood Light with PIR
Installation Instructions
Remove mounting bracket, and use as a template to mark fixing holes.
Secure bracket in location.
Wire the pre-wired floodlight directly to an IP connector or connection box
ensuring correct polarity is observed. Brown – Live, Blue – Neutral,
Green/yellow - Earth.
Offer the fitting back to the mounting bracket and replace the bolts. Adjust the
fitting to the required angle before tightening the bolts.