29
TIME EXCEED
This parameter is available to measure the amount of time that the limit is exceeded.
This parameter is a read only parameter and is viewed in the Set-Up mode, display
code
tLE
.
The parameter will time in minutes and seconds from 0 to 99 minutes and 59 seconds.
After this time the display will change automatically to indicate minutes and tens of
seconds from 100.0 to 999.5. For times greater than 999.5 the display will be
HH
.
The value viewed is the cumulative time that the instrument has been out of limit.
To reset this parameter, select the parameter and with the numeric value in the upper
display, press and hold the UP or DOWN keys. After about 5 seconds, the upper
display will indicate
----
for another 2 seconds, then change to
0.00
. Release the key.
The value will be held through a supply power down/power up cycle.