background image

6159922280_02

7 / 12

01/2017

English

Original instructions.
© Copyright 2017, Desoutter HP2 7SJ UK

All rights reserved. Any unauthorized use 

or copying of the contents or part thereof 

is prohibited. This applies in particular to 

trademarks, model denominations, part numbers 

and drawings. Use only authorized parts. Any 

damage or malfunction caused by the use of 

unauthorised parts is not covered by Warranty or 

Product Liability.

STATEMENT OF USE

This product is designed for versatile industrial 

applications.

No other use is permitted.

For professional use only.
Suitable for industrial environment only.

TECHNICAL DATA

 

● See page 2.

Additional data:

Operating temperature -5°C to 50°C
Storage temperature

-20°C to 75°C

Operating humidity

10%~90% relative 

humidity, non-

condensing

IP65 compliant front panel

 

● Contact your local Desoutter 

representative for more information.

SAFETY INFORMATION

 

● Read these safety instructions carefully.

 

● Keep this user manual for later reference.

 

● Disconnect this equipment from any AC outlet 

before cleaning. Use a damp cloth. Do not use 

liquid or spray detergents for cleaning.

 

● For plug-in equipment, the power outlet socket 

must be located near the equipment and must 

be easily accessible.

 

● Keep this equipment away from humidity.

 

● Put this equipment on a stable surface during 

installation. Dropping it or letting it fall may 

cause damage.

 

● The openings on the enclosure are for 

air convection to protect the equipment 

from overheating. DO NOT COVER THE 

OPENINGS.

 

● Make sure the voltage of the power source is 

correct before connecting the equipment to 

the power outlet.

 

● Place the power cord in a way so that people 

will not step on it. Do not place anything on 

top of the power cord. Use a power cord that 

has been approved for use with the product 

and that it matches the voltage and current 

marked on the product’s electrical range label. 

The voltage and current rating of the cord 

must be greater than the voltage and current 

rating marked on the product.

 

● All cautions and warnings on the equipment 

should be noted.

 

● If the equipment is not used for a long time, 

disconnect it from the power source to avoid 

damage by transient overvoltage.

 

● Never pour any liquid into an opening. This 

may cause fire or electrical shock.

 

● Never open the equipment. For safety 

reasons, the equipment should be opened 

only by qualified service personnel.

 

● If one of the following situations arises, get the 

equipment checked by service personnel:
a. The power cord or plug is damaged.

b. Liquid has penetrated into the equipment.

c. The equipment has been exposed to 

moisture.

d. The equipment does not work well, or you 

cannot get it to work according to the user’s 

manual.

e. The equipment has been dropped and 

damaged.

f. The equipment has obvious signs of 

breakage.

 

● Do not place heavy objects on the equipment.

 

● The unit uses a three-wire ground cable which 

is equipped with a third pin to ground the unit 

and prevent electric shock. Do not defeat 

the purpose of this pin. If your outlet does 

not support this kind of plug, contact your 

electrician to replace your obsolete outlet.

Summary of Contents for 6159327300

Page 1: ...Issue no 02 Date 01 2017 Page 1 12 Copyright 2017 Desoutter HP2 7SJ UK 12 17 touch screen Panel PC Model Part number 12 Panel PC SIGMA CLIENT 6159327300 17 Panel PC INFINITY CLIENT 6159327320 17 Panel...

Page 2: ...ordered with the product Model Part number Power input Weight Power consumption kg lb 12V 24V 30V 12 Panel PC SIGMA CLIENT 6159327300 12V 30V DC 3 9 8 60 27 12W 26 64W 27W 17 Panel PC INFINITY CLIENT...

Page 3: ...mber A B C mm in mm in mm in 12 Panel PC SIGMA CLIENT 6159327300 317 12 48 243 9 57 66 2 60 17 Panel PC INFINITY CLIENT 6159327320 411 16 18 341 13 42 76 2 99 17 Panel PC INFINITY MODULE 6159327330 41...

Page 4: ...6159922280_02 4 12 01 2017 Model Part number A B C D mm in mm in mm in 12 Panel PC SIGMA CLIENT 6159327300 100 3 94 51 2 08 109 4 29 MOUNTING SUPPORT 12 PANEL PC SIGMA CLIENT B D C A...

Page 5: ...art number A B C D mm in mm in mm in 17 Panel PC INFINITY CLIENT 6159327320 100 3 94 174 6 85 270 10 63 17 Panel PC INFINITY MODULE 6159327330 100 3 94 174 6 85 270 10 63 MOUNTING SUPPORT 17 PANEL PC...

Page 6: ...6159922280_02 6 12 01 2017 A B REAR TOP REAR BOTTOM 2 1 3 4 5 6 7 8 9 10 2 4 5 6 1 3 C REAR VIEW 3 1 2 4...

Page 7: ...t from overheating DO NOT COVER THE OPENINGS Make sure the voltage of the power source is correct before connecting the equipment to the power outlet Place the power cord in a way so that people will...

Page 8: ...area network 5 USB to connect USB 2 0 1 1 devices 6 COM 1 to connect RS232 422 485 compatible series devices supports 5 V 7 COM 2 supports 12 V 8 PS 2 KB MS to connect a keyboard and a mouse Reset but...

Page 9: ...6159922280_02 9 12 01 2017 Pb Hg Cd Cr VI PBB PBDE Electronics Module x o o o o o Housing o o o o o o SJ T11364 GB T 26572 GB T 26572 Name and content of harmful substances in products...

Page 10: ...enmaiden lains d nt koskevien direktiivin vaatimusten kanssa jotka koskevat 8 koneita 2006 42 EY 17 05 06 9 elektromagneettista yhteensopivuutta 2014 30 EY 26 02 14 10 matalaj nnitteit 2014 35 EY 26 0...

Page 11: ...z onkowskich i dotycz cej 8 maszyn i urz dze 2006 42 UE 17 05 06 9 Zgodno ci elektro magnetycznej 2014 30 UE 26 02 14 10 niskich napi 2014 35 UE 26 02 14 11 stosowanych norm wzajemnie zgodnych 12 Nazw...

Page 12: ...ives on the approximation of the laws of the Member States relating Fr est sont en conformit avec les exigences de la Directive du conseil concernant les l gislations des tats membres relatives 9 to E...

Reviews: