M may be the following:
A:
Casing and shaft seal cover : Cast iron + cast iron alloy. Impeller and sealing rings: Bronze
B:
Casing and shaft seal cover : Cast iron + cast iron alloy. Impeller and sealing rings: Stainless.
C:
All cast iron
D:
Casing and shaft seal cover: Bronze or NiAlBz. Impeller and sealing rings: NiAlBz or stainless
steel
E:
Special materials
U:
Nonmagnetic material
The pumps can be delivered in other material combinations according to agreement with the supplier.
R may be the following:
02: Monobloc, with bearing in the pump
07: Mounted on base plate with electric motor
09: Pump with bare shaft end
12: Monobloc, without bearing in the pump
13: Spacer, light bearing housing
14: Spacer, heavy bearing housing
15: Spacer, heavy bearing housing and heavy motor bracket (special motor bracket)
16: Compact spacer (i.e. pumps shown in this manual)
Z may be the following:
i : PN16 flanges
j : PN25 flanges
k : Special flange
l : Other shaft seal
m : BS flanges
n : ANSI flanges
o : Shockproof design
p : Other design
q : JIS flanges
Any use of the pump is to be evaluated on the basis of the materials used in the pump. In case of
doubt, contact the supplier.
Pumps in material combinations A and C are primarily used for fresh water.
Pumps in material combination D and E are primarily used for seawater.
If the pumps are designed for special purposes the following is to be indicated:
Pump No.
:
Pump type :
Application :
Comment
:
2.2
TECHNICAL
DESCRIPTION
The noise level indicated is the airborne noise including the motor. The noise depends on the motor
type supplied, as the noise from the pump can be calculated as the noise level of the motor + 2dB(A).
The noise level is for pumps with electric motors.
The capacity of the pump appears from the name plate on the pump. If the pump has been delivered
without motor, the pump capacity is to be indicated on the plate when mounting the motor.