M may be the following: 
A: 

Casing and shaft seal cover : Cast iron + cast iron alloy. Impeller and sealing rings: Bronze 

B: 

Casing and shaft seal cover : Cast iron + cast iron alloy. Impeller and sealing rings: Stainless. 

C: 

All cast iron 

D: 

Casing and shaft seal cover: Bronze or NiAlBz. Impeller and sealing rings: NiAlBz or stainless 
steel 

E: 

Special materials 

U: 

Nonmagnetic material 

 
The pumps can be delivered in other material combinations according to agreement with the supplier. 
 
R may be the following: 
02:  Monobloc, with bearing in the pump 
07:  Mounted on base plate with electric motor 
09:  Pump with bare shaft end 
12:  Monobloc, without bearing in the pump 
13:   Spacer, light bearing housing 
14:   Spacer, heavy bearing housing 
15:  Spacer, heavy bearing housing and heavy motor bracket (special motor bracket) 
16:  Compact spacer (i.e. pumps shown in this manual) 
 
Z may be the following: 
i  :  PN16 flanges 
j  :  PN25 flanges 
k  :  Special flange 
l  :  Other shaft seal 
m  :  BS flanges 
n  :  ANSI flanges 
o  :  Shockproof design 
p  :  Other design 
q  :  JIS flanges 
 
Any use of the pump is to be evaluated on the basis of the materials used in the pump. In case of 
doubt, contact the supplier. 
 
Pumps in material combinations A and C are primarily used for fresh water. 
Pumps in material combination D and E are primarily used for seawater. 
 
If the pumps are designed for special purposes the following is to be indicated: 
 
Pump No. 

:                                                                                                          

Pump type  :                                                                                                          
Application  :                                                                                                          
Comment 

:                                                                                                          

 
2.2

 

TECHNICAL

 

DESCRIPTION 

The noise level indicated is the airborne noise including the motor. The noise depends on the motor 
type supplied, as the noise from the pump can be calculated as the noise level of the motor + 2dB(A). 
The noise level is for pumps with electric motors. 
 
The capacity of the pump appears from the name plate on the pump. If the pump has been delivered 
without motor, the pump capacity is to be indicated on the plate when mounting the motor. 
 

 

Summary of Contents for NSLH Compact Spacer

Page 1: ...entrifugal pump NSLV and NSLH Compact Spacer DESMI Pumping Technology A S Tagholm 1 DK 9400 N rresundby Denmark Tel 45 96 32 81 11 Fax 45 98 17 54 99 E mail desmi desmi com Internet www desmi com Manu...

Page 2: ......

Page 3: ...FITTING IMPELLER 8 6 6 FITTING SHAFT SEAL COVER 8 6 7 FITTING COUPLING 8 6 8 SHAFT 9 7 FROST PROTECTION 9 8 DISMANTLING 9 9 START UP 9 9 1 START UP 10 10 SYSTEM BALANCING 10 11 INSPECTION AND MAINTEN...

Page 4: ...tion and maintenance instructions are divided into two parts covering the groups 215 265 and 330 415 as the designs of these two groups are different The numbers refer to the standard impeller diamete...

Page 5: ...r bracket special motor bracket 16 Compact spacer i e pumps shown in this manual Z may be the following i PN16 flanges j PN25 flanges k Special flange l Other shaft seal m BS flanges n ANSI flanges o...

Page 6: ...Mz Nm Mx Nm Mt 65 215 65 265 650 840 750 1340 510 310 380 700 80 215 80 265 80 330 800 950 850 1500 550 350 400 750 100 215 100 265 100 330 100 415 1000 1250 1150 2000 650 400 500 900 125 215 125 265...

Page 7: ...the necessary safety measures 3 2 WIRING Wiring to be carried out by authorised skilled workmen according to the rules and regulations in force 4 TRANSPORT STORAGE The weights of the pumps in A and D...

Page 8: ...73 and pull off A gentle heating of the pump and motor coupling parts may facilitate the dismantling Remove the screws 22 that keep the shaft seal cover 18 to the pump casing 1 Loosen shaft seal cove...

Page 9: ...ing cover support disc and bearing and press the bearing into place up against the support disc Fit ring lock 12 330 415 Fit cover under bearing 26 6 3 FITTING WATER DEFLECTOR 215 265 Assemble bearing...

Page 10: ...t seal cover in the O ring groove and hold it with a little grease However check the material of the O ring first As standard the material is NITRILE but it may be EPDM which will be damaged by minera...

Page 11: ...Alternatively it is possible to use anti freeze liquids in normal constructions 8 DISMANTLING Before dismantling the pump make sure that it has stopped Empty the pump of liquid before it is dismantle...

Page 12: ...vance It is however decisively important to the quantity of liquid delivered A considerably smaller delivery head than expected will increase the quantity of liquid delivered causing increased power c...

Page 13: ...viewed from shaft end the direction of the arrow Clean or replace Clean the pump Find the leakage repair the fault non return valve not submerged Check data sheet Q H curve and NPSH or contact DESMI...

Page 14: ...HAFT SEAL 11 1 DRAINING THE PUMP When the piping system has been drained note that there is still liquid in the pump Remove the liquid by dismantling the pipe plug 3 at the bottom of the pump 11 2 BEA...

Page 15: ...hours 80 g If the pumped liquid temperature is below 80 C the following types of grease are recommended ESSO Beacon 2 BP Energrease EP grease 2 Shell Alvania grease 2 Mobil Mobil lux grease EP 2 elle...

Page 16: ...ure bar SG iron Max RPM 65 215 16 32 1800 3600 125 265 7 14 1800 1800 65 265 14 5 29 1800 3600 150 330 7 13 27 1800 1800 80 330 15 15 32 1800 3600 150 415 9 13 26 1800 1800 80 215 13 26 1800 3600 150...

Page 17: ...ds Common safety requirements EN12162 2001 A1 2009 Liquid pumps Safety requirements Procedure for hydrostatic testing EN 60204 1 2006 A1 2009 Safety of machinery Electrical equipment of machines item...

Page 18: ...TION RELEVANT FOR DISASSEMBLY OR DISPOSAL AT END OF LIFE No damage materials are used in DESMI pumps please refer to DESMI Green Passport can be sent on request contact a DESMI sales office i e common...

Page 19: ...ring 14 Support disc 15 Bearing cover 16 Sunk key 17 Shaft 18 Shaft seal cover 19 Allen screw 21 O ring 22 Allen screw 36 Pointed screw 58 Copper pipe only on NSLV 59 Hexagon nipple Plug on NSLH 60 Se...

Page 20: ...12 Ring lock 13 Ball bearing 14 Support disc 15 Bearing cover 16 Sunk key 17 Shaft 18 Shaft seal cover 19 Allen screw 21 O ring 22 Allen screw 27 Sealing ring 2 36 Pointed screw 58 Copper pipe only NS...

Page 21: ...key 17 Shaft 18 Shaft seal cover 19 Allen screw 21 O ring 22 Allen screw 27 Sealing ring 2 36 Pointed screw 58 Copper pipe only NSLV 59 Hex nipple Plug on NSLH 60 Set screw 61 Hexagon nipple 63 Motor...

Reviews: