Desmi NSLH Compact Spacer Operation And Maintenance Instructions Download Page 16

 

DESMI Pumping Technology A/S 

14

 

 

Tagholm 1 

 

9400 Nørresundby - Denmark 
Tel.: +45 96 32 81 11 
Fax +45 98 17 54 99 
E-mail

[email protected]

 

www.desmi.com

 

 

 

 

 

 

 

 

13.

 

OPERATING

 

DATA 

 
The following working pressures (pressure in piping incl. the pressure increase caused by the pump), 
number of revolutions and electric motors are allowed in standard pumps: 
 
ø215 pumps are as standard available with motors up to frame size 225 
ø265 pumps are as standard available with motors up to frame size 280 
ø330 pumps are as standard available with motors up to frame size 315 
ø415 pumps are as standard available with motors up to frame size 355 
 

 

 

 

 

 

Pump size 

Max. 

working 

pressure 

[bar] 

Bronze / 

Cast iron 

 

Max. 

working 

pressure 

[bar] 

SG-iron 

 

 

 

 

Max. 

RPM 

 

 

 

 

 

Pump size 

Max. 

working 

pressure 

[bar] 

Bronze / 

Cast iron 

 

Max. 

working 

pressure 

[bar] 

SG-iron 

 

 

 

 

Max. 

RPM 

65-215 

16  

32 

1800 / 3600 

125-265 

14 

1800 / 1800 

65-265 

14.5 

29 

1800 / 3600 

150-330 

7 / 13 

27 

1800 / 1800 

80-330 

15 / 15 

32 

1800 / 3600 

150-415 

9 / 13 

26 

1800 / 1800 

80-215 

13 

26 

1800 / 3600 

150-265 

18 

----- / 1800 

80-265 

14.5 

29 

1800 / 3600 

200-330 

7 / 13 

26 

1800 / 1800 

100-330 

8 / 14 

29 

1800 / 1800 

200-415 

9 / 13 

26 

1800 / 1800 

100-415 

10 / 12.5 

25 

1800 / 1800 

200-265 

10 / 10 

20 

---- / 1800 

100-215 

10 

20 

1800 / 3600 

250-330 

7 / 12 

25 

1800 / 1800 

100-265 

14.5 

29 

1800 / 3600 

250-415 

9 / 12 

25 

1800 / 1800 

125-330 

7 / 12 

25 

1800  

300-415 

9 / 12 

25 

1800 / 1800 

125-415 

9 / 13 

26 

1800 / 1800 

300-525 

14 

25 

1800 / 1800 

125-215 

16 

----- / 1800 

 

 

 

 

 

 
The above-mentioned max. working pressure is 

NOT

 valid for pumps approved by a classification 

society. Pumps approved by classification societies have been pressure tested according to the 
requirements of these societies, i.e. a test pressure of 1.5 x the permissible working pressure. The 
test pressure is stated in the test certificate and stamped into the discharge flange of the pump.  

 

Summary of Contents for NSLH Compact Spacer

Page 1: ...entrifugal pump NSLV and NSLH Compact Spacer DESMI Pumping Technology A S Tagholm 1 DK 9400 N rresundby Denmark Tel 45 96 32 81 11 Fax 45 98 17 54 99 E mail desmi desmi com Internet www desmi com Manu...

Page 2: ......

Page 3: ...FITTING IMPELLER 8 6 6 FITTING SHAFT SEAL COVER 8 6 7 FITTING COUPLING 8 6 8 SHAFT 9 7 FROST PROTECTION 9 8 DISMANTLING 9 9 START UP 9 9 1 START UP 10 10 SYSTEM BALANCING 10 11 INSPECTION AND MAINTEN...

Page 4: ...tion and maintenance instructions are divided into two parts covering the groups 215 265 and 330 415 as the designs of these two groups are different The numbers refer to the standard impeller diamete...

Page 5: ...r bracket special motor bracket 16 Compact spacer i e pumps shown in this manual Z may be the following i PN16 flanges j PN25 flanges k Special flange l Other shaft seal m BS flanges n ANSI flanges o...

Page 6: ...Mz Nm Mx Nm Mt 65 215 65 265 650 840 750 1340 510 310 380 700 80 215 80 265 80 330 800 950 850 1500 550 350 400 750 100 215 100 265 100 330 100 415 1000 1250 1150 2000 650 400 500 900 125 215 125 265...

Page 7: ...the necessary safety measures 3 2 WIRING Wiring to be carried out by authorised skilled workmen according to the rules and regulations in force 4 TRANSPORT STORAGE The weights of the pumps in A and D...

Page 8: ...73 and pull off A gentle heating of the pump and motor coupling parts may facilitate the dismantling Remove the screws 22 that keep the shaft seal cover 18 to the pump casing 1 Loosen shaft seal cove...

Page 9: ...ing cover support disc and bearing and press the bearing into place up against the support disc Fit ring lock 12 330 415 Fit cover under bearing 26 6 3 FITTING WATER DEFLECTOR 215 265 Assemble bearing...

Page 10: ...t seal cover in the O ring groove and hold it with a little grease However check the material of the O ring first As standard the material is NITRILE but it may be EPDM which will be damaged by minera...

Page 11: ...Alternatively it is possible to use anti freeze liquids in normal constructions 8 DISMANTLING Before dismantling the pump make sure that it has stopped Empty the pump of liquid before it is dismantle...

Page 12: ...vance It is however decisively important to the quantity of liquid delivered A considerably smaller delivery head than expected will increase the quantity of liquid delivered causing increased power c...

Page 13: ...viewed from shaft end the direction of the arrow Clean or replace Clean the pump Find the leakage repair the fault non return valve not submerged Check data sheet Q H curve and NPSH or contact DESMI...

Page 14: ...HAFT SEAL 11 1 DRAINING THE PUMP When the piping system has been drained note that there is still liquid in the pump Remove the liquid by dismantling the pipe plug 3 at the bottom of the pump 11 2 BEA...

Page 15: ...hours 80 g If the pumped liquid temperature is below 80 C the following types of grease are recommended ESSO Beacon 2 BP Energrease EP grease 2 Shell Alvania grease 2 Mobil Mobil lux grease EP 2 elle...

Page 16: ...ure bar SG iron Max RPM 65 215 16 32 1800 3600 125 265 7 14 1800 1800 65 265 14 5 29 1800 3600 150 330 7 13 27 1800 1800 80 330 15 15 32 1800 3600 150 415 9 13 26 1800 1800 80 215 13 26 1800 3600 150...

Page 17: ...ds Common safety requirements EN12162 2001 A1 2009 Liquid pumps Safety requirements Procedure for hydrostatic testing EN 60204 1 2006 A1 2009 Safety of machinery Electrical equipment of machines item...

Page 18: ...TION RELEVANT FOR DISASSEMBLY OR DISPOSAL AT END OF LIFE No damage materials are used in DESMI pumps please refer to DESMI Green Passport can be sent on request contact a DESMI sales office i e common...

Page 19: ...ring 14 Support disc 15 Bearing cover 16 Sunk key 17 Shaft 18 Shaft seal cover 19 Allen screw 21 O ring 22 Allen screw 36 Pointed screw 58 Copper pipe only on NSLV 59 Hexagon nipple Plug on NSLH 60 Se...

Page 20: ...12 Ring lock 13 Ball bearing 14 Support disc 15 Bearing cover 16 Sunk key 17 Shaft 18 Shaft seal cover 19 Allen screw 21 O ring 22 Allen screw 27 Sealing ring 2 36 Pointed screw 58 Copper pipe only NS...

Page 21: ...key 17 Shaft 18 Shaft seal cover 19 Allen screw 21 O ring 22 Allen screw 27 Sealing ring 2 36 Pointed screw 58 Copper pipe only NSLV 59 Hex nipple Plug on NSLH 60 Set screw 61 Hexagon nipple 63 Motor...

Reviews: