09 : With bare shaft end.
10 : Special-tailored according to task.
Any use of the pump is to be evaluated on the basis of the materials used in the pump. In
case of doubt, contact the supplier.
Pumps in material combinations A and C are primarily used for fresh water.
Pumps in material combination D are primarily used for sea water.
2.3 TECHNICAL DESCRIPTION
The noise level indicated is the airborne noise including the motor. The noise depends on the
motor type supplied, as the noise from the pump can be calculated as the noise level of the
motor + 2dB(A).
The capacity of the pump appears from the name plate on the pump. If the pump has been
delivered without motor, the pump capacity is to be indicated on the plate when mounting the
motor.
The permissible loads on the flanges appear from the following table:
Pump
Fv N
Fh N
∑ F N
S32-25-110
1250
950
1550
200
S50-32-135N
1250
950
1550
200
S70-50-175N
1350
1000
1700
200
S70-50-220N
1350
1000
1700
200
S70-50-275N
1350
1000
1700
250
S80-70-175N
1450
1050
1800
270
S80-70-220N
1450
1050
1800
270
S80-70-275N
1450
1050
1800
270
S100-80-175N
1800
1250
2200
470
S100-80-220N
1800
1250
2200
470
S100-80-275N
1800
1250
2200
470