11. INSPECTION AND MAINTENANCE
Inspect the shaft seal for leaks at regular intervals.
Activate the relief valve at regular intervals in order to check the function. If the valve is
choked, replace or clean it, if possible.
-
Before inspection of a pump without guard check that the pump cannot be started
unintentionally.
-
The system is to be without pressure and drained of liquid.
-
The repairman must be familiar with the type of liquid which has been pumped as
well as the safety measures he is to take when handling the liquid.
11.1 DRAINING THE PUMP
When the piping system has been drained, note that there is still liquid in the pump. Remove
the liquid by dismantling the pipe plug (3) in the inlet cover of the pump.
11.2 BEARING
The pump is equipped with a ball bearing which is dimensioned for a nominal life of 25,000
working hours. The bearing is lubricated for life and requires no attention but is to be replaced
in case of noise or bearing wear.
12. REPAIRS
12.1 ORDERING SPARE PARTS
When ordering spare parts please always state pump type and serial No. (appears from the
name plate of the pump). See also spare parts drawing with item Nos.
13. OPERATING DATA
The following max. working pressures are allowed:
(10.2 mWC = 1 bar)
PUMP
S32-25-110
S50-32-135N
S70-50-175N
S70-50-220N
S70-50-275N
PRESSURE
mWC
45
45
65
100
150
Pump
S80-70-175N
S80-70-220N
S80-70-275N
S100-80-175N
S100-80-220N
PRESSURE
mWC
65
100
160
65
100
Pump
S100-80-275N
S125-80-220N
S125-80-275N
S125-100-220N
PRESSURE
mWC
150
100
150
100