![Desmi ESLHT/-17 W180 Operation And Maintenance Instructions Download Page 6](http://html.mh-extra.com/html/desmi/eslht-17-w180/eslht-17-w180_operation-and-maintenance-instructions_2487031006.webp)
_______________________________________________________________________________
DESMI Pumping Technology A/S
6
Tagholm 1
9400 Nørresundby
–
Denmark
Tel: +45 96 32 81 11 Fax: +45 98 17 54 99
E-mail:
The lifting straps must not bear against sharp edges and corners.
5.
DISMANTLING
Before dismantling the pump make sure that it has stopped. Empty the pump of
liquid before it is dismantled from the piping system. If the pump has been
pumping dangerous liquids you are to be aware of this and take the necessary
safety measures.
If the pump has been pumping hot liquids, take great care that it is drained
before it is removed from the piping system.
5.1
DISMANTLING
OF
ESLHT25-180N/A-17
W180
/
ESLHT40-180N/A-17
W180
5.1.1 DISMANTLING COUPLING
Dismantle the stainless steel pipe (30) then
remove the coupling guard (39)
Unscrew the nut & washer (43 & 44 ) and
remove the motor
Unscrew the coupling point screw and
remove the coupling (38) with the cooling
30
39
43
,
44
38
47