![Desmi ESLHT/-17 W180 Operation And Maintenance Instructions Download Page 17](http://html.mh-extra.com/html/desmi/eslht-17-w180/eslht-17-w180_operation-and-maintenance-instructions_2487031017.webp)
_______________________________________________________________________________
DESMI Pumping Technology A/S
17
Tagholm 1
9400 Nørresundby
–
Denmark
Tel: +45 96 32 81 11 Fax: +45 98 17 54 99
E-mail:
When assembling the pump again, check the pump shaft for damages in the form of marks,
burrs, or upsetting of the shaft end.
Damages, if any, are to be remedied by means of a file and fine emery cloth. This work has to
be done very carefully. If this is not done carefully, the pump shaft will scratch the shaft seal
when fitted.
13.
OPERATING
DATA
The following working pressures (pressure in piping incl. the pressure increase caused by the
pump) and number of revolutions are allowed in standard pumps.
Pump
Max.
working pressure[bar]
SG-iron
Max.
working pressure[bar]
SS
Max.RPM
ESLHT25-180
14
16
3600
ESLHT40-180
14
16
3600
The above max. operating pressure is valid at 180°C water
The above-mentioned max. working pressure is a design value
– delivered pumps are
pressure tested according to actual application requirements and actual flange standards.
For instance the above-mentioned max. working pressure is
NOT
valid for pumps approved
by a classification society. Pumps approved by classification societies have been pressure
tested according to the requirements of these societies, i.e. a test pressure of 1.5 x the
permissible working pressure. The test pressure is stated in the test certificate and stamped
into the discharge flange of the pump.