background image

This Manual is applicable to 

 

Revised January 18th 2017 

De Sisti SUPER LED F10 Vari White 

 

Pag 4. 

C.  Before  hanging  the  luminaire  ensure  that  the  suspension  point  (or  the  stand)  is  properly rated to accept 

the luminaire weight. 

D.  In case of pole operated use, fit only a P.O. stirrup from De Sisti Lighting. 
E.  A suitable secondary safety suspension device (safety cable, chain or equivalent) must be fitted between 

the suspension point and the eyelet at the front of the body . 

 
WARNING : 
DO NOT  MOUNT THE LUMINAIRE ON A NORMALLY FLAMMABLE SURFACE . 
 

6.  INSTALLATION INSTRUCTIONS 

 

The following procedure should be adopted: 

 

Before connecting the luminaire to the electrical mains ensure that: 
A.  Earth line is present on the power socket. 
B.  The mains voltage is within the rated range of the luminaire (see technical data on the rating label) 
C.  The front safety shield is present and in good condition. 

It consists of a fresnel lens made by borosilicate untoughened glass,  
with a Diamater = 250 mm , thickness = 7 mm typ ( 4 min ). 

 
             WARNINGS :  

 

Do not operate the product if the ambient temperature exceeds 40° C 

 

Provide a minimum clearance of 0,1m (4 in.) around fans and air vents. 

 

SHIELDS, LENSES SAFETY OR DICHROIC GLASSES SHALL BE CHANGED IF THEY HAVE 
BECOME  VISIBLY  DAMAGED  TO  SUCH  AN  EXTENT  THAT  THEIR  EFFECTIVENESS  IS 
IMPAIRED, FOR EXAMPLE BY CRACKS OR DEEP SCRATCHES.  

 

THE LUMINAIRE  SHALL ONLY BE USED  COMPLETE  WITH ITS PROTECTIVE SHIELD 

 

D.  Applying power: 
Never connect to dimmer power. Install a power plug on the power cable using the following pin assigment: 

1 : Neutral   2 : Live   Green/Yellow : Ground - This fixture must be connected to ground. 

Make sure the local power voltage is within the range specified. If so; connect the power cable and turn the 
power on. 

 

E.  Stand Alone operation: 
Using the navigation buttons and display readout ( refer to the “Local Menu” chapter ) 
navigate to Manual and set the desired intensity (for additional operations see “Local Menu” chapter) 

 

F.  DMX operation: 
Connect a DMX cable 
Navigate to Address mode (Addr) and set the desired address, (refer to the “Local Menu” chapter). 
Connect to DMX controller (refer to the “Channel Setting” in the “Local Menu” chapter) and Use it. 

 
 

7.  LOCAL MENU 

 
The  SUPER  LED  F10  VW  has  a  GRAPHIC  DISPLAY  backlit,  with  two  local  knobs,  each  one  having  a 
push/click function in addition to the rotation: 

 
 

 

KNOB 1  

It is as a DEFAULT the CCT Variation Knob,  

 

By rotating it clockwise the CCT Changes from 

 

2.750°K up to 6.900 °K. 

 

If such a knob is kept pushed, it provides a FAST ACTION  

 

on the KNOB 2 which is normally the DIMMING 

 

 

 

Display 

It is a Graphic, backlit LCD Display. It contains all the relevant 
information for the product setup and performances, such as CCT, 
DMX Address, DMX Level, LED Temperature and local dimming.

 

 

When the local knobs are not used for more than 5 seconds the 
display back illumination will go OFF and the display itself will go in 
STAND BY Mode. It will go ON again anytime a KNOB is activated. 

 
KNOB 2 

It is as a DEFAULT the DIMMING Variation Knob,  

 

By rotating it clockwise the Dimming of the Light Changes from 

 

0up to Full Light Output. 
If such a knob is pushed, it has the selection or enter function to, for 
instance, enter into a Menu. 

Summary of Contents for SUPER LED F10 VW Vari-White

Page 1: ...gn innovation and manufacturing of lighting products for the professional Entertainment Industry means you can depend upon the quality of this product The SUPER LED F10 is a compact highly efficient Fresnel lens spotlight using a LED ARRAY combined with the DE SISTI Patented optical system to optimize the photometric performances of LED ARRAYS when utilized in combination with either Fresnels or P...

Page 2: ...ively equipped with For DMX 1 XLR5 pin Panel Mount Male DMX IN 1 XLR5 pin Panel Mount Female DMX OUT For Mains Supply 1 20A Powercon NAC3MPA BLUE POWER IN 1 20A Powercon NAC3MPB WHITE POWER OUT It is recommended to Daisy Chain a Max of 10 fixtures even if the limitations imposed by DMX Standards are for an higher q ty of units and even if the Powercon Connections are rated for 20A max SUPER LED F1...

Page 3: ...ore any maintenance work or opening the FUSE HOLDER Risk of serious injury Electrical connections IMPORTANT The cores in this mains lead are colored in accordance with the following code Europe America Ground Green yellow Green or green yellow Neutral Blue White Live Brown Black In case the colors of the cores do not correspond to the colors of the connection points on your plug please proceed as ...

Page 4: ...on the power cable using the following pin assigment 1 Neutral 2 Live Green Yellow Ground This fixture must be connected to ground Make sure the local power voltage is within the range specified If so connect the power cable and turn the power on E Stand Alone operation Using the navigation buttons and display readout refer to the Local Menu chapter navigate to Manual and set the desired intensity...

Page 5: ... is the default setting The Fixture utilises 2 DMX Circuits the BASE CIRCUIT set in the ADDRESS is the Coarse Dimming the second Circuit BASE 1 is the Fine Dimming Of course to benefit of the 16 bits function the corresponding circuits on the DMX LIGHTING BOARD shall also be set at 16 bits The DMX channels BASE 2 and BASE 3 are dedicated to the CCT Variation Control as described previously When th...

Page 6: ...DMX device is connected to it once the Console will be acting it will take priority over any local control To turn the Auto save ONplease follow these instructions rotate KNOB 2 and select Auto save Off press KNOB 2 to highlight the status of Auto Save in this case Off rotate KNOB 2 to turn the status of Auto save to ON and press it Leave the setting in this condition the light will ignore any DMX...

Page 7: ... soft damp cloth 4 Check the condition of the safety shield see chapter Installation Instructions before every use 5 Check Power supply cable and DMX control cable proper conditions 10 SAFETY STANDARDS Europe The product conforms the Applicable European Directives Standards Low Voltage Directive 73 23 EEC as amended by 93 68 EEC EMC Directive 89 336 EEC as amended by 92 31 EEC by 93 68 EEC Europen...