This Manual is applicable to
Revised January 18th 2017
De Sisti SUPER LED F10 Vari White
Pag 3.
4. CHARACTERISTICS AND PERFORMANCE DATA
DESCRIPTION
VALUE
DESCRIPTION
VALUE
LED Power
200 W
Protection Type
IP 22
Power
Consumption
220W @ 230 V
230W @ 120 V
Max
Housing temperature
70 °C
DMX Data link
USITT DMX512-A
This product uses a 5-pin XLR for
DMX input and output.
Use a shielded data cables.
Do not overload the daisy chain.
Up to a maximum of 32 devices
can be used on a single DMX
chain.
Weight of Fixture
M.O.
P.O.
13,5 kg.
14,8 kg.
Weight of barndoor
4 leaf
8 leaf
1,4 kg.
1,65 kg.
DMX
Channels:
Total 4 DMX Channels:
Dimmer / Light Intensity 16 BIT
Base : Dimmer Gross
Base +1: Dimmer Fine
Base +2: CCT Control
Base +3: CCT Control Mode
Weight of color frame
0,6 kg.
Size of scrims & color
frame
Seat Diameter
Acc.ies Diameter
306 mm.
305 mm ( 12” )
Size of Barndoor ring
Seat Diameter
Ring Diameter
314 mm.
313 mm.(
≅
12”
1/4
)
Protection
Class
Class 1– ground connection required
Lens diameter
250 mm.
Specifications subject to change without notice.
5. SAFETY INSTRUCTIONS
Professional use: This luminaire has been designed for professional use and must be operated by
qualified personnel only. Not for residential use.
Grounding: WARNING: THIS LUMINAIRE MUST BE GROUNDED
WARNING: Disconnect Power CORDS before
any maintenance work or opening the FUSE HOLDER.
Risk of serious injury.
Electrical connections: IMPORTANT The cores in this mains lead are colored in accordance with the
following code:
Europe
America
Ground
Green & yellow
Green or green & yellow
Neutral
Blue
White
Live
Brown
Black
In case the colors of the cores do not correspond to the colors of the connection points on your plug, please
proceed as follows:
•
the green or green and yellow core must be connected to the connection point marked with the letter E or
with the symbol
or colored in green or in green - yellow;
•
the blue (or white) core must be connected to the connection point marked with the letter N or colored in
black;
•
the brown (or black) core must be connected to the connection point marked with the letter L or colored in
red.
Working conditions
Working Position
Lighting fixture: Max. Tilting
±
90° from horizontal
Ambient Temperature,
t
a
at the place of installation and Storage
Minimum 10°C, m40°C
Humidity
at the place of installation and Storage
25-80% (not condensing)
Minimum distances from
inflammable surfaces
Top
Back
Sides
Front
0,3 m.
0,15 m.
0,15 m.
1 m.
The luminaire should never be OPERATED close to inflammable materials. The ones indicated in the above
table are the minimum distances recommended. Other requirements for safe use are:
A. Do not cover the apertures of the luminaire housing. They are essential for correct ventilation.
B. Use only original accessories and spares from De Sisti Lighting.