This Manual is applicable to the
Revised April 2nd 2015
De Sisti SOFT LED 4
Pag 5
.
•
SHIELDS, LENSES SAFETY OR DICHROIC GLASSES SHALL BE CHANGED IF THEY HAVE BECOME
VISIBLY DAMAGED TO SUCH AN EXTENT THAT THEIR EFFECTIVENESS IS IMPAIRED, FOR EXAMPLE
BY CRACKS OR DEEP SCRATCHES.
•
THE LUMINAIRE SHALL ONLY BE USED COMPLETE WITH ITS PROTECTIVE SHIELD
D.
Applying power:
Never connect to dimmer power. Install a power plug on the power cable using the following pin assigment:
1 : Neutral 2 : Live Green/Yellow : Ground - This fixture must be connected to ground.
Make sure the local power voltage is within the range specified. If so; connect the power cable and turn the power
on.
E.
Stand Alone operation:
Using the navigation buttons and display readout ( refer to the “Local Menu” chapter )
navigate to Manual and set the desired intensity (for additional operations see “Local Menu” chapter)
F.
DMX operation:
Connect a DMX cable
Navigate to Address mode (Addr) and set the desired address, (refer to the “Local Menu” chapter).
Connect to DMX controller (refer to the “Channel Setting” in the “Local Menu” chapter) and Use it.
8.
LOCAL MENU
PGM PORT
For Firmware Upgrade
Ù
FUNCTION 1
Scrolling UP / Increases value “function key”
ENTER
Select / Confirm
Ú
FUNCTION 2
Scrolling DOWN / Decreases value “function key”
Display
When the push button are not used for more than 15
seconds the display will go OFF. It will go ON again
anytime a push button is activated.
DMX Presence
Shows the presence of DMX (LED lit = DMX present)
DEFAULT SETTINGS ARE INDICATED IN BOLD LETTERS ON THE FOLLOWING TABLE:
The following are the BASIC FUNCTIONS and COMMANDS that are provided on the LOCAL MENU of the LED FRESNEL. The
unit is provided with a USER MENU accessible instantly on the product.
The unit has also a SERVICE MENU that is only accessible through a PASSWORD and is reserved for QUALIFIED and TRAINED
PERSONNEL:
1st MENU
Displayed
(
scrolling with the
Ù
and the
Ú
buttons)
2nd MENU
Displayed
(after pressing the
X
that stands for ENTER)
Explanation of Each MENU FUNCTION
DMX ADDRESS
This Function is to SET the DMX address from 1 to 512 (Product is delivered with default
settingof the DMX address at 1)
Once the C001 is displayed, act on the
Ù
button to increase the address to the desired
value.
Temporary push will increment the value by 1, if the button is kept pushed the increment on
numbers is getting fast.
Once the desired Address number is accomplished press X (“ENTER”) to make it active
LOCAL DIMMING CONTROL
This Function is to LOCALLY DIM the LED INTENSITY from 0 to 100% (Product is
delivered with default setting of the DIMMER at 0).
The intensity goes in increments of 1/100% so the display will show 000% with the dimmer
at 0% and FULL with the dimmer at 100%.
Temporary push will increment the value by 1/100, if the button is kept pushed the
increment on numbers is getting fast.
Once the desired Lighting Level is accomplished and it is wanted to leave that level and go
to other functions of the MENU, press “ENTER”.
LOCAL OR REMOTE CONTROL SETTINGS
The LED Fresnel has the facility to block the LOCAL DIMMING SETTING and maintain it
when the POWER is turned first OFF and than ON again.
This allows for the LIGHT to be TUNED and FOCUSED locally and its dimming level can be
blocked, so that for instance a system lighting a SET can be operated by a remote switch or
simple brakers by TURNING POWER ON.
The relevant menu to access this function is CTRL, to enter in this menu press X (“ENTER”), it
is than possible to select either DMX or AUTO by acting on the
Ù
or
Ú
button and than
press X (“ENTER”) again. The machine is set to DMX as default.
•
In DMX mode: the Fixture accepts DMX control….if in this mode the local DIMMING
CONTROL is SET to a level the Light behaviour will follow the HTP (Highest Takes
Precedence) modality, in other words it will keep the local DIMMING setting until the
DMX level of the specific channel will be higher, from that level onwards the DMX
level will take precedence. In this condition if the DMX connection is removed, the
light will keep the last level….until power is ON. It will reset and Start at 0after Power
OFF and ON again.
In AUTO mode: the light will ignore any DMX control. In this mode any local
dimming setting will be maintained and will be automatically recalled after power off,
when turning the power on again.