3.

 

POWER AND DMX DAISY CHAIN 

 
 
 

The SOFT LED permits both POWER and DMX DAISY CHAIN. 
In fact each Fixture is respectively equipped with: 
 
For DMX: 

 

1 XLR5 pin Panel Mount Male (DMX IN) 

 

1 XLR5 pin Panel Mount Female (DMX OUT) 

 
For Mains Supply 

 

1 20A Powercon NAC3MPA BLUE (POWER IN) 

 

1 20A Powercon NAC3MPB WHITE (POWER OUT) 

 
It is recommended to Daisy Chain a Max of 10 fixtures, even if the limitations imposed by DMX Standards are for an higher q.ty of units and 
even if the Powercon Connections are rated for 20A max.  

 

4.

 

SAFETY INSTRUCTIONS 

 

Ü

 

Professional use: This luminaire has been designed for professional use and must be operated by qualified personnel only. Not for residential 

use. 

Ü

 

Grounding: WARNING: THIS LUMINAIRE MUST BE GROUNDED 

Ü

 

WARNING:  Disconnect Power CORDS before  

 

any maintenance work or opening the FUSE HOLDER.  
Risk of serious injury. 

 

Ü

 

Electrical connections: IMPORTANT The cores in this mains lead are colored in accordance with the following code: 

 

Europe 

America 

Ground 

Green & yellow 

Green or green & yellow 

Neutral 

Blue 

White 

Live 

Brown 

Black 

In case the colors of the cores do not correspond to the colors of the connection points on your plug, please proceed as follows: 

 

the green or green and yellow core must be connected to the connection point marked with the letter E or with the symbol      or colored in 
green or in green - yellow; 

 

the blue (or white) core must be connected to the connection point marked with the letter N or colored in black; 

 

the brown (or black) core must be connected to the connection point marked with the letter L or colored  in red. 

 
Working conditions 

 

Ü

 

Working Position 

 

Lighting fixture: Max. Tilting 

±

90° from horizontal 

Ü

 

Ambient Temperature, ta 
at the place of installation and Storage 

Minimum 10°C, m40°C 

Ü

 

Humidity 
at the place of installation and Storage 

25-80% (not condensing) 

Ü

 

Minimum distances from inflammable 
surfaces 

Top 

Back 

Sides 

Front 

0,2 m. 

0,1 m. 

0,1 m. 

0,75 m. 

 

The luminaire should never be OPERATED close to inflammable materials. The ones indicated in the above table are the minimum distances 
recommended. Other requirements for safe use are:  
 

A.

 

Do not cover the apertures of the luminaire housing. They are essential for correct ventilation.  

B.

 

Use only original accessories and spares from De Sisti Lighting. 

C.

 

Before hanging the luminaire ensure that the suspension point (or the stand) is properly rated to accept the luminaire weight. 

Summary of Contents for Soft LED 2 Vari-White

Page 1: ...is product The SOFT LED 2 Vari White is a innovative 60W LED SOFTLIGHT with a COLOR RENDERING INDEX CR higher than 95 at any CCT within a range from a minimum of 2 800 K to a maximum of 6 600 K it provides a smooth and soft shadow projecting beam yet within a controlled field that makes it ideal for multiple camera set ups The Lighting Fixture is DMX Controlled and includes a number of parameters ...

Page 2: ...This Manual is applicable to Soft LED 2 Vari White Revised August 2018 2 YOKE AND ACCESSORIES ASSEMBLY ...

Page 3: ...se the colors of the cores do not correspond to the colors of the connection points on your plug please proceed as follows the green or green and yellow core must be connected to the connection point marked with the letter E or with the symbol or colored in green or in green yellow the blue or white core must be connected to the connection point marked with the letter N or colored in black the bro...

Page 4: ...connected to ground Make sure the local power voltage is within the range specified If so connect the power cable and turn the power on E Stand Alone operation Using the navigation buttons and display readout refer to the Local Menu chapter navigate to Manual and set the desired intensity for additional operations see Local Menu chapter F DMX operation Connect a DMX cable Navigate to Address mode ...

Page 5: ... Address is SET in order to return to the MAIN MENU it is necessary to rotate KNOB 2 counter clock wise to return to the EXIT item and then select it by pressing KNOB 2 itself 1st MENU Displayed scrolling with the Ù and the Ú buttons 2nd MENU Displayed after pressing the X that stands for ENTER Explanation of Each MENU FUNCTION LOCAL DIMMING CONTROL This function is to LOCALLY DIM THE LED INTENSIT...

Page 6: ...ower on again LOCAL OR REMOTE CONTROL SETTINGS The LED Fresnel has the facility to block the LOCAL DIMMING and CCT SETTING and maintain it when the Power is turned first OFF and then ON again This allows for the Light to be tuned and focused locally and its dimming plus CCT level can be blocked so tghat for instance a system lighting a Set can be operated by a remote switch or simple brackers by t...

Page 7: ... K from 6600 K TLCI 96 Ü Front Fixture s Opening Front 30 5 cm base x 14 7 cm height surface 427 cm 2 Ü Protection Class Class 1 ground connection required Specifications subject to change without notice 8 DIMENSIONS 9 PERIODIC INSPECTION MAINTENANCE This product requires very little routine maintenance if any but has special cleaning instructions Disconnect fixture from power and allow it to cool...

Page 8: ... Ü Low Voltage Directive 73 23 EEC as amended by 93 68 EEC Ü EMC Directive 89 336 EEC as amended by 92 31 EEC by 93 68 EEC Ü Europen Standards EN 60598 2 17 EN 60598 1 EN 55015 EN 61547 Disposing of this product Help preserve the environment Ensure that this product is recycled at the end of its life This product is in compliance with the RoHS and WEEE directives ...

Reviews: