background image

 

 

 

User Guide for On Hold Appliance OH-4910     Document G/01144     Issue 2     Page 2 

MADE IN AUSTRALIA 

Instructions 

 

To Record Your Own Message 

1.

 

Connect the message source machine (eg. tape player, sound card etc.) to the 

On Hold Messenger Appliance

 3.5 mm 

TS phone record socket (you can use mono or stereo). The output level from the source should be no more than about  
1 (one) Volt peak to peak. If this can not be measured, a couple of trial runs will be necessary to determine the volume 
on the source player required to achieve a loud and clear but undistorted recording. 

2.

 

Momentarily press the recessed Record button on the 

On Hold Messenger Appliance

 with a pen or pencil and the red 

Record LED will pulse (please note that the green Play LED also stays on at this time). 

3.

 

Press the play button on the cued source machine within 30 seconds. 

4.

 

The 

On Hold Messenger Appliance

 will automatically start recording when audio is detected and then stop recording 

when you press the Record button again, or when four (or eight) minutes have elapsed. 

 

Playback 

1.

 

Plug the 

On Hold Messenger Appliance

 into the Phone system MOH port and do a test. Simply call in and ask the 

operator to put you on hold. You can adjust the output volume control using a small bladed screwdriver. Turning it 
clockwise increases the output. 

Please consult the factory if more output volume is required. This is common to 

some older Commander

 and PABX systems. There is an output boost setting inside the On Hold Messenger 

box.

 

 

Specifications 

Enclosure 

Injection moulded ABS (

acrylonitrile-butadiene-styrene

). 

Dimensions 

50 mm x 110 mm x 80 mm. 

Operating Temperature Range 

-10 

 +70 

°

 C. 

Message Recording /Playback 

 

Input Sample Rate 

8 kHz. 

Upper pass band 

3.4 kHz. 

Message retention 

100 years. 

Record Cycles 

100, 000. 

Messages length 

Up to four minutes (eight minutes optional). 

Record Input level 

 1 V p-p (350 mV RMS). 

Output level 

 4.4 V p-p (adjustable). 

Frequency range 

500 Hz 

 3.4 kHz. 

Power requirement 

6 - 12 Vdc 50 mA (600 mW), polarity insensitive 
(Power adaptor supplied separately) 

Power connector 

2.1 mm concentric  

MOH connector 

RJ12 6P2C socket 

Record Input connector 

3.5 mm stereo (mixed to mono) TS phone socket 

Displays 

Playing LED indicator (green), Recording LED (red). 

Isolation 

Complies to TS001 

NZ Telepermit 

PTC 212/92/005 

ACA Supplier’s Code Number 

N468. 

Warranty Two 

years. 

 

 

Est. 1968 

 

Telephone: +613 9758 5933 

Facsimile: +613 9758 5560 

Email: 

[email protected]

 

Web Site: 

www.design2000.com.au

 

 