DESi HS 102 WKS User Manual Download Page 11

4.7. Programmable Relay

There is also a programmable relay output 

inside the

 outdoor siren.

To make the settings related to the relay, follow the instructions below when the alarm is 

disarmed

[ADMIN PASS.] 

 <MENU> 

 <9> 

 VIEW THE INDICATOR

Press <STAY> after you have finished your choice.

After this steps, the buzzer will give a warning tone and your choice will be active.

4.8. Wireless Detector Tamper

 Protection

The system alarms if the motion detector, magnetic contact and wireless detectors cover

 try 

to 

open (the alarm needs to be armed)

If you want 

tamper

 

protection

 even when the system 

is disarmed, follow the instructions below when the alarm is 

disarmed

:

[ADMIN PASS] 

 <MENU> 

 <9> 

 VIEW THE INDICATOR

Press <STAY> after you have finished your choice.

After this steps, the buzzer will give a warning tone and your choice will be active.

4.9. Adjusting Sound Alerts

 For Delay Time

If you want your system to beep during the delay time, follow the instructions below when 
the alarm is 

disarmed

:

[ADMIN PASS.] 

 <MENU> 

 <9> 

 VIEW THE INDICATOR

Press <STAY> after you have finished your choice.

After this steps, the buzzer will give a warning tone and your choice will be active.

4.10. Zone Programming

Fully reportable area means 'zone'

 in your system

. If one detector is connected to the desired 

area, 'zone' and detector have the same 

name

. If more than one detector is connected to the 

desired area, 'zone' will be the combine of all 

the 

detectors

.

11

Choice

Display

 (

META

 / 

PRO

)

Feature

5. Zone

 / 

solid means

enable, not means disable

Press <5> 

to select.

Standby and delay times warning tone

Feature

 

Display

 (

META

 / 

PRO

)

 

Choice

4. Zone

 / 

solid means

enable, not means disable

Press <4> 

to select.

Checking the wireless detector cover tamper

 

protection 

when the alarm is not activated.

Choice

Display

 (

META

 / 

PRO

)

Feature

6. Zone

 / 

solid means

enable, not means disable

Press <6> to 

select.

Relay is activated during alarm

RF Zone

 / 

RFI 

solid means 

enable, not means disable

Press <7> to 

select.

Relay is activated when armed

PWR

 / 

PWR 

solid means 

enable, not means disable

Press <8> 

to select.

Relay is activated when 5. Zone is 

open circuit

Summary of Contents for HS 102 WKS

Page 1: ...P R O L I N E M E T A L I N E Home Office Alarm Systems USER MANUAL WKS WTKS WTGKS WTKS WTGKS 1 2 3 4 5 6 7 8 9 MENU 0 1 2 3 6 5 4 ENTER PWR RFI AREA STAY ARM DIS ARM ...

Page 2: ...ng Disarming Alarm via Remote Access 3 7 Additional Device Control Options via Remote Access 4 SETTINGS 4 1 PasswordOptions 4 1 1 Administrator Password 4 1 2 UserPasswords 4 1 3 Remote Access Password 4 1 4 PanicPassword 4 2 Delay Time During Arming 4 3 Delay Time Before Alarm 4 4 Arming Disarming Tones Level 4 5 AutoArming Options 4 6 Outdoor Siren 4 7 Programmable Relay 4 8 Wireless Detector Ta...

Page 3: ...8 RestoreFactorySettings for Voice Call Options 14 14 14 14 15 15 15 15 15 16 16 16 16 16 16 17 18 19 Maintenance You can clean external surfaces by soft slightly damp cloth Never use abrasive chemicals or water for this purpose Be careful not to change the direction of the detectors during cleaning and do not damage connections and cables Battery life of the wireless detectors may change dependin...

Page 4: ...sor 1x Wired Magnetic Contact 2x Remote Controller 1x Battery 2x Warning Label Voice Caller Landline Connection Available Voice Caller GSM Connection Available WTKS WTGKS WKS Plastic Control Panel 1x Wired Motion Sensor 1x Wired Magnetic Contact 2x Remote Controller 1x Battery 2x Warning Label Voice Caller Landline Connection Available The motion detector in WTKS and WTGKS is wireless and there is...

Page 5: ...on 1 5 2Special Arming Type 2 With Remote Controller First press and then press button2times 5 Arming Disarming Enables the alarm silently Disarm the alarm and the phone call if pressed while the siren is sounding Panic Alarm Protect all parts of the system from water and heat Your device has a battery that can operate the system for approximately 2 days to prevent power failures It is recommended...

Page 6: ...ive Area For fire detectors or for a different reason you can have some areas which need to be in control even when the alarm is disarmed see 4 10 Programming the Zones Ÿ Panic Area You can activate the voice call before the siren rings see 4 10 Programming the Fields Ÿ Auto Arming Your device is equipped with automatic arming option to prevent accidental disarming or against forgetting to arm see...

Page 7: ...emote access disarm process will not listed 7 1 2 3 6 5 4 PWR RFI PROLINE Indicator LEDs Cause For Alarm Display META PRO Wired Zone 1 Wired Zone 2 Wired Zone 3 Wired Zone 4 Wired Zone 5 Wired Zone 6 Wiress Zones 1 Zone 1 2 Zone 2 3 Zone 3 4 Zone 4 5 Zone 5 6 Zone 6 RF Zone RFI Display META PRO 1 Zone 1 2 Zone 2 3 Zone 3 4 Zone 4 5 Zone 5 6 Zone 6 RF Zone RFI RF Zone Zone 1 Zone 2 Zone 3 Zone 4 Zo...

Page 8: ...dule should connect to supply input of the device Dial the phone number connected to device and ring 5 times After the fifth ring the system automatically answers the call and the buzzer sounds will hear then remote access password has to entered from the phone key pad When you hear confirming tone the extra equipment is actived by pressing the button 2 or by pressing button 3 the extra equipment ...

Page 9: ...word follow the instructions below when the alarm is disarmed ADMIN PASS MENU 4 TONE MENU 9 NEW PASS ENTER To deactivate the remote access feature press ENTER without entering a new password 4 1 4 Panic Password This password is used when malicious people want to disarm the alarm by threat If the system has been disarmed with a panic password it will call the phone numbers which entered at setup s...

Page 10: ...ADMIN PASS MENU 6 VIEW THE INDICATOR Press STAY after you have finished your choice After this steps the buzzer will give a warning tone and your choice will be active Feature Display META PRO Choice 1 Zone 1 solid means enable not means disable Press 1 to select When the alarm is armed the outdoor siren will be activated against tamper 2 Zone 2 solid means enable not means disable Press 2 to sele...

Page 11: ...ructions below when the alarm is disarmed ADMIN PASS MENU 9 VIEW THE INDICATOR Press STAY after you have finished your choice After this steps the buzzer will give a warning tone and your choice will be active 4 10 Zone Programming Fully reportable area means zone in your system If one detector is connected to the desired area zone and detector have the same name If more than one detector is conne...

Page 12: ... are determined according to the order in wireless detectors are enrolled 4 11 One by One Wireless Zone Programming If there are too many wireless detectors in the system adjusting them will take long time Instead you can make changes by selecting the wireless zone Follow the instructions below when the alarm is disarmed ADMIN PASS MENU 3 ZONE NUMBER STAY See chart above STAY MENU 12 Choice Displa...

Page 13: ... long beep indicates that the device has enrolled the controller Enrolling a wireless magnetic contact move the magnet closer to the magnetic contact and then move away warning led on the magnetic contact blink Enrolling the wireless motion detector press and release the tamper switch Enrolling the wireless shock detector shake the detector for signal the warning light on the detector blink Enroll...

Page 14: ...e respond is factory default voice caller message If you want to record a different message the telephone has to connected directly to control panel during installation follow the instructions below when the alarm is disarmed ADMIN PASS MENU 4 WARNING TONE MENU 7 1 RECORD YOUR MESSAGE max 10sec 2 Carefully open the control panel while the device is energized When the panel cover opened tamper prot...

Page 15: ...rect Call Selection Secure dialing allows device to start dial after receiving the dial tone factory default setting If device cannot call due to interference on the telephone line a direct dial option should be tried by following the instruction when the alarm is disarmed ADMIN PASS MENU 4 WARNING TONE MENU 0 1 Press 0 for SAFE CALL Press 1 for DIRECT CALL ENTER 5 7 Remote Programming Of Voice Ca...

Page 16: ...ond subscriber number press 2 SUBSCRIBER NUMBER 4 Digit ENTER 6 3 Entering Alarm Monitoring Center Phone Numbers To set the alarm monitoring center phone numbers follow the instructions below when the alarm is disarmed ADMIN PASS MENU 4 WARNING TONE MENU for first phone number press 1 for second phone numbers press 2 ALARM MONITORING CENTER PHONE NUMBER ENTER 6 4 Forwarding Arming Disarming Notifi...

Page 17: ...ess 0 ENTER To choose which line the device will use first follow the instructions below when the alarm is not activated ADMIN PASS MENU 4 WARNING TONE MENU 0 6 to choose landline first press 1 to choose GSM line first press 0 ENTER If the dive cannot make a call for any reason over the specified line the system will switch to an alternative line 17 First pin code of the SIM card must be canceled ...

Page 18: ...1 JP3 TAMP Siren Akü SWCH TTK TTK External Siren Card MAGNET ALARM 12V 0V TAMPER Magnetic Contact T R NA Programmable Relay Output Motion Detector Card Before installation please call DESi authorized services dealers Do not allow to interfere your device anyone other than the authorized service You can visit www desi com tr for a list of current authorized services WARNING 220V Input FUSE Battery ...

Page 19: ... Input Key Pad Connection NC O T R Keypad NO Smoke Detector AkÜ TTK T R 12 V GND A1 A2 A3 A4 GND A5 A6 GND YD NA NK O Landline and Phone Connection Be sure to connect the GND terminal to the building earth line to protect it from lightning and high voltage WARNING Earth Line TEL FUSE TAMPER BUTTON T R A N S F O R M E R TRANSFORMER ...

Page 20: ... DESi Alarm ve Güvenlik Sistemleri A Ş Topkapı Maltepe Cd Anadolu Sk No 1 Topkapı Maltepe İstanbul T 444 33 74 F 0212 576 64 77 Topkapı Maltepe Cd Anadolu Sk No 1 Topkapı Maltepe İstanbul T 444 33 74 F 0212 576 64 77 ...

Reviews: