OFF/SET/LOCK

key switch - this switch controls the

power to the ionizer.  When the SET position is
selected, it allows the balance and fan speed to be
adjusted.  When the LOCK position is selected, a
LOCK indicator is illuminated on the front panel of
the ionizer. In this position, the balance and fan
speed controls are disabled and the key is
removable.  In the OFF position, power is shut off to
the ionizer and the key is removable.

• 

FAN

speed adjustment switches are used to set 

the fan speed to the desired level that provides 
the best performance while minimizing operator 
discomfort. With the key switch in the SET 
position, pressing and holding the + symbol will 
increase fan speed, and the - symbol will decrease
fan speed.  Relative fan speed is displayed on the
front panel indicator.

• 

BAL

controls are used to adjust the balance of 

the ionizer and are used in conjunction with a 
charged plate analyzer.  Pressing the “+” symbol will
shift the balance offset positive, while pressing the “-”
symbol will shift it negative. Adjustment should be
made with a charged plate analyzer located 24"
directly under the ionizer. The BAL controls, like the
FAN speed, are only adjustable when the key switch
is in the SET position.

• 

I/O PORT

serves a dual purpose.  It accepts 

signals from the optional Auto Calibration Unit and
automatically calibrates the ionizer when the key
switch is in the SET position. It also outputs ionizer
status signals that can be useful for remote
monitoring.

• 

IEC INPUT CONNECTOR

based on the 

International IEC 60320 Standard, allows the  power
to be disconnected at the ionizer and  provides a
fuse drawer for a 5mmx20mm fuse. The fuse drawer
may be opened when the cordset is removed.  In
addition, an IEC Outlet on the opposite end of the
ionizer can supply power for a charged plate
analyzer, or for daisy-chaining a second unit.

TB-2087

Page 4 of 8

Front Panel Display and
Controls

See figure 3.

System Status

is the information center on the front of

the ionizer.  From it, the operator can easily check the
operational status of the ionizer.

PWR

- this indicator will normally be green when the

ionizer is operating correctly.  When the autobalance
circuit can no longer adjust for dirty emitter pins, this
indicator will turn red and begin to flash.  It is normal
for it to flash for a few seconds each time the ionizer
is turned on. This indicator will be on when the key
switch is either in the "SET" or "LOCK" position.

• 

LOCK

- when the key switch on the end of the 

ionizer is set to lock, this indicator will display a 
distinctive blue light.  This makes it readily apparent
that the ionizer has its settings locked, preventing
unauthorized adjustment.

• 

AIRFLOW

- this display indicates relative airflow 

output from the fans.  If the key switch is in the 
"SET" position and the "+" or "-" button are pressed
and held, the fan speed will increase or decrease
with a corresponding change in the AIRFLOW
display.  As fan speed is increased, the display will
move to the right.

• MINOR ADJUSTMENTS ACCESS 

(see figure 4).

Each fan zone may be balanced separately.  The
adjustments are designed for minor corrections to
balance one fan to another.  Overall balance
adjustments should be done with the "BAL" switches
on the end panel.

• 

VR6, VR5, VR2, and VR1

- are the zone balance

adjustments for the zones 1 through 4 respectively.
Zone 1 is closest to the right end.  24" models will
only have VR6 and VR5 adjustments.  These
adjustments are covered in the section titled
"Calibration Instructions".

Figure 3. Front panel display and controls

DESCO WEST

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EAST

- 90 Hudson Road, Canton, MA 02021 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: http://www.desco.com

                               5 / 9

                               5 / 9

Summary of Contents for 60478

Page 1: ... System Limited Excellent Integrated System Limited Stocking Distributor Stocking Distributor Click to view price real time Inventory Delivery Lifecycle Information Click to view price real time Inventory Delivery Lifecycle Information Desco Desco 60480 60480 For any questions you can email us directly For any questions you can email us directly sales integrated circuit com sales integrated circui...

Page 2: ...rated circuit com Website www integrated circuit com CRITICAL ENVIRONMENT C E SERIES OVERHEAD IONIZER OWNER S MANUAL DESCO WEST 3651 Walnut Avenue Chino CA 91710 909 627 8178 Fax 909 627 7449 DESCO EAST 90 Hudson Road Canton MA 02021 781 821 8370 Fax 781 575 0172 Web Site http www desco com TB 2087 3 02 Page 1 of 8 Made in America ...

Page 3: ...nization or other charge mitigating techniques shall be used at the workstation to neutralize electrostatic fields on all process essential insulators if the electrostatic field is considered a threat Ionization is used to neutralize charges on process necessary insulators and isolated semiconductors Some examples of process necessary insulators are the PC board itself plastic test stands plastic ...

Page 4: ...d be supported as well to provide protection against any hazard to the operator S hooks are provided with each unit to facilitate mounting using the chain suspension method The ideal mounting height is 24 above the work surface although the ionizer may be located slightly higher or lower if required For maximum performance care should be taken to insure that the intake grills for the fans are not ...

Page 5: ...wer may be opened when the cordset is removed In addition an IEC Outlet on the opposite end of the ionizer can supply power for a charged plate analyzer or for daisy chaining a second unit TB 2087 Page 4 of 8 Front Panel Display and Controls See figure 3 System Status is the information center on the front of the ionizer From it the operator can easily check the operational status of the ionizer P...

Page 6: ...y switch can be set to the LOCK position and normal workstation use resumed If the ionizer is used in a manner not specified by the manufacturer the protection provided by the ionizer may be impaired Maintenance As with all ionizers periodic maintenance will be needed to provide optimum performance Reference IEC 61340 5 2 1paragraph 5 2 9 The frequency of monitoring ionizers really depends on how ...

Page 7: ...s will often choose a much shorter interval especially if the product being worked on is very sensitive On very sensitive product we recommend checking the calibration any time an emitter cassette is removed and replaced Warning Do not attempt to calibrate this unit without proper equipment such as a charged plate analyzer Adjustments to the calibration controls should be performed by authorized t...

Page 8: ...old the BAL switch to find its most positive point use the BAL switch to find its most negative point calculate the midpoint and set the balance using the BAL buttons to that point Example if the most positive point is 40V and its most negative point is 10V you would set the balance to 15V TB 2087 Page 7 of 8 5 Adjust each fan s output by placing the charge analyzer plate underneath it and turning...

Page 9: ...LY DISCLAIMED The express warranty will not apply to defects or damage due to accidents neglect misuse alterations operator error or failure to properly maintain clean or repair products Limit of Liability Electronic ionizers use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will Desco or any seller be responsible or liable for any ...

Reviews: