background image

Distributor of Desco: Excellent Integrated System Limited

Datasheet of 60480 - EMITTER BOARD O'HD IONIZER PAIR 
Contact us: [email protected] Website: www.integrated-circuit.com

•  Non-volatile adjustments for balance and fan speed

are maintained in the absence of power.

•  Lockout key with distinctive front panel indicator 

prevents unauthorized adjustment.

•  Balance is individually adjustable at each fan zone.

•  Flashing front panel signal indicates when cleaning

is needed.

•  IEC input and output connectors allow daisy-chaining

of a second unit.

•  Stainless steel and powder-coated aluminum

construction for durability and long life.

Specifications

Input Power:

120VAC   250mA (24" model) 
120VAC   400mA (48" model)
220VAC   250mA (24" model) 
220VAC   400mA (48" model)

IEC Outlet:

Allows a second unit to be 
daisy-chained

Fuse:

5x20mm 3 amp time lag

Air Flow:

80-170 CFM (24" model)
160-340 CFM (48" model)

Emitters:

100% Tungsten, replaceable

Ionization Type:

Steady-state DC

Balance:

0+/-10 volts at set-up at 24" 
above charged plate analyzer

Weight:

6.2 lbs. (24" model)
11.1 lbs. (48" model)

Size:

2" x 6" x 24"
2" x 6" x 48"

Mounting:

(2) ¼" mounting holes each end

Installation

The Desco C/E ionizer is designed to mount above the
work area, providing even coverage without using
valuable work surface area.  Mounting is a matter of
personal preference, and may be accomplished with
brackets attached to a shelf, or the unit may be
suspended by chain.  Whatever method is used, care

should be taken to insure that the mounting is secure
and capable of supporting the weight of the unit.  The
power cord should be supported as well to provide
protection against any hazard to the operator.

"S" hooks are provided with each unit to facilitate
mounting using the chain suspension method.  The
ideal mounting height is 24" above the work surface,
although the ionizer may be located slightly higher or
lower if required.  For maximum performance, care
should be taken to insure that the intake grills for the
fans are not obstructed.

Turn the power key switch to the "OFF" position.  Plug
the IEC end of the cord into the ionizer and the other
end into a properly wired outlet.  We recommend that
the outlet used by the ionizer be tested before use and
periodically checked for correct wiring and a good solid
ground.  The C/E ionizer depends on a good ground
for proper balancing.

Safety interlock switches are provided internally on
each emitter cassette.  This ensures that power is
cut off in the event that any cassette is removed or
not fully installed.

The grills below each fan function as sensors and
feedback a signal to the balance circuitry.  Therefore, it
is important not to hang or attach anything to the fan
grills.

Controls and Functions

Figure 2. Control Panel

• The 

CONTROL PANEL

is located on the right  hand

end of the ionizer.  It provides controls for fan speed,
balance, and a key switch to prevent unauthorized
adjustment of the controls.  Also located on the
control panel is an I/O port that may be used for auto
calibration (with optional Auto Calibration Unit, item
number 60491).  It also is used to provide output
signals to allow remote monitoring of ionizer status.

TB-2087

Page 3 of 8

DESCO WEST

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178 • Fax (909) 627-7449 

DESCO EAST

- 90 Hudson Road, Canton, MA 02021 • (781) 821-8370 • Fax (781) 575-0172 • Web Site: http://www.desco.com

                               4 / 9

                               4 / 9

Summary of Contents for 60478

Page 1: ... System Limited Excellent Integrated System Limited Stocking Distributor Stocking Distributor Click to view price real time Inventory Delivery Lifecycle Information Click to view price real time Inventory Delivery Lifecycle Information Desco Desco 60480 60480 For any questions you can email us directly For any questions you can email us directly sales integrated circuit com sales integrated circui...

Page 2: ...rated circuit com Website www integrated circuit com CRITICAL ENVIRONMENT C E SERIES OVERHEAD IONIZER OWNER S MANUAL DESCO WEST 3651 Walnut Avenue Chino CA 91710 909 627 8178 Fax 909 627 7449 DESCO EAST 90 Hudson Road Canton MA 02021 781 821 8370 Fax 781 575 0172 Web Site http www desco com TB 2087 3 02 Page 1 of 8 Made in America ...

Page 3: ...nization or other charge mitigating techniques shall be used at the workstation to neutralize electrostatic fields on all process essential insulators if the electrostatic field is considered a threat Ionization is used to neutralize charges on process necessary insulators and isolated semiconductors Some examples of process necessary insulators are the PC board itself plastic test stands plastic ...

Page 4: ...d be supported as well to provide protection against any hazard to the operator S hooks are provided with each unit to facilitate mounting using the chain suspension method The ideal mounting height is 24 above the work surface although the ionizer may be located slightly higher or lower if required For maximum performance care should be taken to insure that the intake grills for the fans are not ...

Page 5: ...wer may be opened when the cordset is removed In addition an IEC Outlet on the opposite end of the ionizer can supply power for a charged plate analyzer or for daisy chaining a second unit TB 2087 Page 4 of 8 Front Panel Display and Controls See figure 3 System Status is the information center on the front of the ionizer From it the operator can easily check the operational status of the ionizer P...

Page 6: ...y switch can be set to the LOCK position and normal workstation use resumed If the ionizer is used in a manner not specified by the manufacturer the protection provided by the ionizer may be impaired Maintenance As with all ionizers periodic maintenance will be needed to provide optimum performance Reference IEC 61340 5 2 1paragraph 5 2 9 The frequency of monitoring ionizers really depends on how ...

Page 7: ...s will often choose a much shorter interval especially if the product being worked on is very sensitive On very sensitive product we recommend checking the calibration any time an emitter cassette is removed and replaced Warning Do not attempt to calibrate this unit without proper equipment such as a charged plate analyzer Adjustments to the calibration controls should be performed by authorized t...

Page 8: ...old the BAL switch to find its most positive point use the BAL switch to find its most negative point calculate the midpoint and set the balance using the BAL buttons to that point Example if the most positive point is 40V and its most negative point is 10V you would set the balance to 15V TB 2087 Page 7 of 8 5 Adjust each fan s output by placing the charge analyzer plate underneath it and turning...

Page 9: ...LY DISCLAIMED The express warranty will not apply to defects or damage due to accidents neglect misuse alterations operator error or failure to properly maintain clean or repair products Limit of Liability Electronic ionizers use high voltage corona discharge and should not be used in or near flammable or explosive environments In no event will Desco or any seller be responsible or liable for any ...

Reviews:

Related manuals for 60478