background image

DESCO WEST 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST 

- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

TB-3019

 Page 1 of 5

© 2019 DESCO INDUSTRIES INC

Employee Owned

Dual-Wire Dual Operator Monitor

Installation, Operation and Maintenance

Description

The Desco 

19665

 Dual-Wire Dual Operator Monitor 

monitors two operators and two ESD worksurfaces 

eliminating the need for periodic testing and 

record keeping of wrist straps. The Dual-Wire Dual 

Operator Monitor uses low-voltage steady state DC 

continuous-loop technology to continuously monitor 

(versus pulsed or intermittent) dual-wire wrist strap 

functionality. Independent audio and visual alarm 

conditions make it easy to identify the status of the 

worksurfaces and operators. Two operator remotes 

with 10 foot cables are included for use at adjacent 

workstations. Each monitor is calibrated with accepted 

procedures and standards traceable to the National 

Institute of Standards and Technology (NIST) and 

includes a NIST certificate.
ANSI/ESD S20.20 section 7.3 states “Compliance 

verification records shall be established and maintained 

to provide evidence of conformity to the technical 

requirements.” Per ANSI/ESD S1.1 Annex A.3 Daily 

(wrist strap system) testing may be omitted if constant 

monitoring used.” Per ESD Handbook ESD TR 20.20 

section 5.3.2.4.4 “Typical Test programs recommend 

that wrist straps that are used daily should be tested 

daily. However, if the products that are being produced 

are of such value that knowledge of a continuous, 

reliable ground is needed, and then continuous 

monitoring should be considered or even required.”

March 2019

Figure 1. Desco Dual-Wire Dual Operator Monitor

  TECHNICAL BULLETIN TB-3019 

Made in the

United States of America

The Dual-Wire Dual Operator Monitor and its 

accessories are available in the following item numbers:

Item

Description

19665

Dual-Wire Dual Operator Monitor

50524

Limit Comparator

50525

Replacement Operator Remote Kit, Black

50526

Replacement Operator Remote Kit, White

19262

Replacement Power Adapter, 12 VDC

Packaging

1  Dual-Wire Dual Operator Monitor

1  Power Adapter, 12VDC, with interchangeable plugs

  (North America, UK/Asia, Europe)

2  Operator Remotes with Attached Cables 

  (1 Black, 1 White)

2  Mat Monitor Cords (1 Black, 1 White)

2  Mat Ground Cords

1  Monitor Ground Cord

1  Universal Snap Kit

1  Certificate of Calibration

Summary of Contents for 19665

Page 1: ...ords shall be established and maintained to provide evidence of conformity to the technical requirements Per ANSI ESD S1 1 Annex A 3 Daily wrist strap system testing may be omitted if constant monitoring used Per ESD Handbook ESD TR 20 20 section 5 3 2 4 4 Typical Test programs recommend that wrist straps that are used daily should be tested daily However if the products that are being produced ar...

Page 2: ...Monitors a worksurface mat for proper dissipative resistance and static charges Connect the black monitor cord here K Data Output For manufacturer use only L Alarm Audible Adjustment Turn the trimpot counter clockwise to increase the audible alarm volume and clockwise to decrease it Installation 1 Determine the mounting location of the Dual Wire Dual Operator Monitor The front panel should be visi...

Page 3: ...eds to pierce and clinch bottom side of mat Snap needs to be at least 12 apart or 72 max OPERATOR 1 WORKSURFACE OPERATOR 2 WORKSURFACE 10mm PUSH CLINCH SNAP 10mm PUSH CLINCH SNAP BENCH GROUND MAT 1 WIRING WHITE CABLE MAT 2 WIRING BLACK CABLE WRIST STRAP MONITOR WRIST STRAP MONITOR ELECTRIC GROUND OPERATOR 2 REMOTE JACK BLACK CABLE OPERATOR 2 REMOTE JACK WHITE CABLE Screw allows ground cord to be b...

Page 4: ...rances See TB 6542 for more information Figure 5 EMIT 50524 Limit Comparator for Dual Wire Monitors Specifications Input Voltage and Frequency External Adapter AC DC Power Adapter Power Input 100 240 VAC 50 60 Hz Power Output 12 VDC 0 50 A Cable Length 5 ft 1 5 m Operating Temperature 50 to 95 F 10 to 35 C Environmental Requirements Indoor use only at altitudes less than 6500 ft 2 km Maximum relat...

Page 5: ... Website Desco com TB 3019 Page 5 of 5 2019 DESCO INDUSTRIES INC Employee Owned Figure 7 Operator Remote dimensions Replacement remotes are available as Desco items 50525 and 50526 Limited Warranty Warranty Exclusions Limit of Liability and RMA Request Instructions See the Desco Warranty Desco com Limited Warranty aspx ...