background image

DESCO WEST 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST 

- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

TB-3054

 Page 6 of 6

© 2017 DESCO INDUSTRIES, INC.

Employee Owned

Limited Warranty, Warranty Exclusions, Limit 

of Liability and RMA Request Instructions

See the Desco Warranty - 

http://desco.descoindustries.com/Limited-Warranty.aspx

Specifications

Input Voltage and 

Frequency

(External Adapter)

AC/DC Power Adapter
Power Input: 

100-240VAC, 50/60 Hz
Power Output: 

24VDC @ 150mA
Cable Length: 

5 ft. (1.5 m)

Operating Temperature 50 to 95°F (10 to 35°C)
Environmental 

Requirements

Indoor use only at altitudes 

less than 6500 ft. (2 km)
Maximum relative humidity 

of 80% up to 85°F (30°C) 

decreasing linearly to 50% @ 

85°F (30°C)

Dimensions

3.87" L x 2.08" W x .90" H

(98 mm x 53 mm x 23 mm)

Weight

0.1 lbs. (0.05 kg)

Operator Test Range* 500 kilohms to 10 megohms 

impedance

Worksurface Test 

Limit**

10 megohms (±10%)

Operator Test Voltage 1.2V peak-to-peak @ 1.2µA, 

open circuit

Worksurface Test 

Voltage

5 to 7.5V, open circuit

Alarm Response Time <50 ms
Country of Origin

United States of America

*This cannot be verified with standard DC test 

equipment.  The continuous monitor is an impedance 

sensing device, and the limits are determined by the 

magnitude and angle of the impedance.
**The worksurface mat must have a conductive 

layer such as Dual Layer Rubber or Dissipative 

3-Layer Vinyl with conductive buried layers.  Desco 

workstation monitors are not recommended for use with 

homogeneous matting.

Summary of Contents for 19234

Page 1: ...7 The Multi Mount Monitor and its accessories are available as the following item numbers Item Description 19228 Multi Mount Monitor North America 19229 Multi Mount Monitor with Jewel Wrist Strap North America 19234 Multi Mount Monitor Universal Power Adapter 19236 Multi Mount Monitor with Jewel Wrist Strap Universal Power Adapter 19258 Power Adapter 100 240VAC Input 24VDC 150mA Output IEC Inlet 1...

Page 2: ...f electrical current less than 1 volt coil cord signal required to generate the waveform has never caused reported skin irritation and is extremely safe for use in voltage sensitive applications such as disk drive manufacturing WORKSURFACE CHANNEL The Multi Mount Continuous Monitor s circuitry is sufficiently sensitive to detect extremely low current allowing it to be used with mats having a resis...

Page 3: ...perator is not properly grounded B Monitored Operator Jack Where the operator inserts the wrist cord banana plug C Worksurface Ground LEDs When the green LED is illuminated the worksurface mat is properly grounded When the red LED is illuminated the worksurface mat is not properly grounded D Operator Ground LEDs When the green LED is illuminated the operator is properly grounded When the red LED i...

Page 4: ...r supply The monitor is now powered NOTE Worksurface must have a conductive layer such as Dual Layer Rubber or Dissipative 3 Layer Vinyl or Micastat Dissipative Laminate with conductive buried layers Desco continuous monitors are not recommended for use with homogeneous matting Figure 6 Screw allows ground cord to be bolted to mat to keep cord from disconnecting Worksurface Snaps must be 12 to 72 ...

Page 5: ...oil cord for continuity or damage Examine the wrist strap and confirm that it has a secure fit If you have dry skin apply an approved dissipative hand lotion such as Menda 35659 Reztore ESD Hand Lotion When leaving the area a person can take the coil cord along or leave it attached to the monitor in park position NOTE Removing the banana plug from the monitor s operator jack will disable the audio...

Page 6: ...ft 2 km Maximum relative humidity of 80 up to 85 F 30 C decreasing linearly to 50 85 F 30 C Dimensions 3 87 L x 2 08 W x 90 H 98 mm x 53 mm x 23 mm Weight 0 1 lbs 0 05 kg Operator Test Range 500 kilohms to 10 megohms impedance Worksurface Test Limit 10 megohms 10 Operator Test Voltage 1 2V peak to peak 1 2µA open circuit Worksurface Test Voltage 5 to 7 5V open circuit Alarm Response Time 50 ms Cou...

Page 7: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Desco 19228 ...

Reviews: