DESCO WEST
- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178
DESCO EAST
- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website:
TB-3054
Page 6 of 6
© 2017 DESCO INDUSTRIES, INC.
Employee Owned
Limited Warranty, Warranty Exclusions, Limit
of Liability and RMA Request Instructions
See the Desco Warranty -
http://desco.descoindustries.com/Limited-Warranty.aspx
Specifications
Input Voltage and
Frequency
(External Adapter)
AC/DC Power Adapter
Power Input:
100-240VAC, 50/60 Hz
Power Output:
24VDC @ 150mA
Cable Length:
5 ft. (1.5 m)
Operating Temperature 50 to 95°F (10 to 35°C)
Environmental
Requirements
Indoor use only at altitudes
less than 6500 ft. (2 km)
Maximum relative humidity
of 80% up to 85°F (30°C)
decreasing linearly to 50% @
85°F (30°C)
Dimensions
3.87" L x 2.08" W x .90" H
(98 mm x 53 mm x 23 mm)
Weight
0.1 lbs. (0.05 kg)
Operator Test Range* 500 kilohms to 10 megohms
impedance
Worksurface Test
Limit**
10 megohms (±10%)
Operator Test Voltage 1.2V peak-to-peak @ 1.2µA,
open circuit
Worksurface Test
Voltage
5 to 7.5V, open circuit
Alarm Response Time <50 ms
Country of Origin
United States of America
*This cannot be verified with standard DC test
equipment. The continuous monitor is an impedance
sensing device, and the limits are determined by the
magnitude and angle of the impedance.
**The worksurface mat must have a conductive
layer such as Dual Layer Rubber or Dissipative
3-Layer Vinyl with conductive buried layers. Desco
workstation monitors are not recommended for use with
homogeneous matting.