Resistance Value 

Test Output - LED

Red jack “A”  -    675K:

Red (Low-hazard)

Green jack “B”  -  825K:

Green (OK-in limits)

Green jack “C”  -  8.5M:

Green (OK-in limits)

Yellow jack “D” - 11.5M:

Red (High resistance)

Step 3:

Repeat the procedure testing across jacks B,

C, and D.  The different resistance ranges should give
the display shown above.  If the tester does not meet
calibration specifications, contact factory for adjustment
information, or ask for Technical Bulletin TB-3000.

Figure 3. Testing 98280 for “PASS” and “FAIL” ranges
as indicated on calibration unit.

CALIBRATION OF THE MODEL 98280
FOOT STRAP TESTER

Step 1:

Connect one of the test leads to common point

banana jack labeled "E" on 07010. Connect the
opposite end of test lead to 98280 tester's foot strap
jack located on the front of the unit and switch the
selector switch to “FOOT STRAP”.

Figure 4. Connecting test lead common from 07010 to
98280.

Step 2:

Connect the second test lead to the 675K jack

labeled "A" on the 07010. Touch the opposite end of
test lead to touch tester plate and press down on tester

with enough pressure to activate the test circuit.
Observe the LED's for the proper response as
indicated below.  Be sure to hold the cord at an
insulated point, so that the resistance value is not
affected by the body.  

Resistance Value 

Test Output - LED

Red jack “A”  -    675K:

Red (Low-hazard)

Green jack “B”  -  825K:

Green (OK-in limits)

Green jack “C”  -  8.5M:

Green (OK-in limits)

Yellow jack “D” - 11.5M:

Red (High resistance)

Step 3:

Repeat the procedure testing across jacks B,

C, and D.  The different resistance ranges should give
the display shown above.  If the tester does not meet
calibration specifications, contact factory for adjustment
information, or ask for Technical Bulletin TB-3000.

Figure 5. Testing 98280 for “PASS” and “FAIL” ranges
as indicated on calibration unit.

CALIBRATION OF THE MODEL 19350 
WRIST STRAP TESTER  

Step 1:  

Connect one of the test leads to common

point banana jack labeled “E” on 07010.  Connect the
opposite end of test lead to one of the 19350’s ground
jacks located on the front edge of the unit.  

Figure 6.  Connecting test lead common from 07010 to
19350.

© 2003 DESCO INDUSTRIES INC.

Employee Owned

Summary of Contents for 07010

Page 1: ...hat testers are in calibration that are used to verify the parameters of wrist straps and foot grounders The 07010 Calibration Unit easily pays for itself Instead of returning to Desco a Calibration House or even your Metrology Department testers can be NIST calibrated where located in the factory being out of service only a couple minutes No need to have an extra replacement Tester Remove the cal...

Page 2: ...010 to 98280 Step 2 Connect the second test lead to the 675K jack labeled A on the 07010 Touch the opposite end of test lead to touch tester plate and press down on tester with enough pressure to activate the test circuit Observe the LED s for the proper response as indicated below Be sure to hold the cord at an insulated point so that the resistance value is not affected by the body Resistance Va...

Page 3: ...cuit needs to be tested individually For detailed information on these testers please ask for Technical Bulletin TB 2040 Wrist Strap Test Circuit Step 1 Connect one of the test leads to common point banana jack labeled E on 07010 Connect the opposite end of test lead to the 19250 s wrist cord jack located on the face of the unit Step 2 Connect the second test lead to the 675K jack labeled A on 070...

Page 4: ...t misuse alterations operator error or failure to properly maintain clean or repair products Limit of Liability In no event will Desco or any seller be responsible or liable for any injury loss or damage direct or consequential arising out of the use of or the inability to use the product Before using users shall determine the suitability of the product for their intended use and users assume all ...

Reviews: