5

These are a few facts that can help you under

-

stand and enjoy your direct-vent fireplace:
•  The venting system may be routed to the 

outside  of  your  home  in  several  ways.  It 
may  vent  through  the  roof  (vertical)  or  it 
may vent to an outside/exterior wall (hori

-

zontal). The  vent  pipe  installation  is  very 
important  to  allow  for  proper  operation. 
You  must  follow  the  venting  instructions 
very carefully for either vertical or horizontal 
applications.

•  This fireplace may be installed in any room 

of your house provided all local codes and 
these installation instructions are followed.

Figure 2 - Common Fireplace Locations

Flush with a wall

Through exterior wall 
enclosed in a chase

Corner 
installation

Figure 3 - Fireplace Bottom Dimensions

D

RW

FW

21 

1

/

8

"

29"

41"

LOCAL CODES

LOCATION AND SpACE 
REqUIREMENTS

Determine the safest and most efficient loca

-

tion for your DESA Heating, LLC direct-vent 
fireplace.  Make  sure  that  rafters  and  wall 
studs are not in the way of the venting system. 
Choose a location where the heat output is 
not affected by drafts, air conditioning ducts, 
windows or doors. Figure 2 shows some com

-

mon locations. Be aware of all restrictions and 
precautions before deciding the exact location 
for your fireplace and termination cap.
When deciding the location of your fireplace, 
follow these rules:
•  Do not connect this fireplace venting to a 

chimney flue serving a separate solid-fuel 
burning fireplace or appliance.

•  Due to high temperatures, do not locate this 

fireplace in high traffic areas, windy or drafty 
areas or near furniture or draperies.

•  Proper clearances must be maintained.
•  If your fireplace is to be installed directly on 

carpeting, vinyl tile or any combustible mate

-

rial other than wood, it must be installed on a 
metal or wood panel extending the full width 
and depth of the fireplace. See Figure 3.

Install and use fireplace with care. Follow all 
local  codes. In the absence  to local  codes, 
use the current 

National Fuel Gas Code ANSI 

Z223.1/NFPA 54*

 (USA) or the current 

CSA-

B149.1 Installation Code

 (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT FEATURES

•  The blower requires electricity. If you plan 

to install the blower at a later date, do not 
forget to wire the outlet at the bottom of the 
fireplace when framing.

•  Each time you turn on your fireplace, you 

may notice some amount of condensation 
on  the  inside  of  the  fireplace  glass. This 
is  normal  and  will  disappear  after  10-20 
minutes of operation.

•  Your  direct-vent  gas  fireplace  system 

(fireplace and venting) is a balanced and 
sealed gas operating unit. It requires ap

-

proximately  10-20  minutes  of  operating 
time before the flame pattern stabilizes.

PRE-INSTALLATION PREPARATION

Summary of Contents for VVC36NE Series

Page 1: ...mable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your bu...

Page 2: ...IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble op erate or service this log set Improper use of this log set can cause serious injury or death from burns fire expl...

Page 3: ...sory not approved for use with this fire place WARNING This appliance is only for use with the type of gasindicatedontheratingplate Thisapplianceisnotconvertible for use with other gases unless a cert...

Page 4: ...e gas valve and pilot light before cleaning fireplace 6 Have venting system inspected annually by a qualified service person If needed have venting system cleaned or repaired See Cleaning and Maintena...

Page 5: ...ireplace follow these rules Do not connect this fireplace venting to a chimney flue serving a separate solid fuel burning fireplace or appliance Due to high temperatures do not locate this fireplace i...

Page 6: ...age of venting system When using snow blowers do not direct snow towards vent termination area Pre Installation Preparation Continued Clearances Minimum clearances to combustibles for the fireplace ar...

Page 7: ...ouver Opening 3 2 1 4 5 6 7 Wall Figure 5 Framing Clearances for Corner Installation Figure 6 Clearances for Combustible Mantels Pre Installation Preparation Continued A B E F G H D C Nailing Tabs Ref...

Page 8: ...00 and 50 000 12 30 cm in Canada if between 10 000 and 100 000 12 30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6...

Page 9: ...pe components and terminations The venting system must terminate on the outside of the structure and can not be at tached to a chimney or flue system serving a separate solid fuel or gas burning appli...

Page 10: ...male ends of adjacent pipes Push pipe sections together and twist one section clockwise approximately one quarter turn until sections are fully locked see Figure 8 Note Horizontal runs of vent must be...

Page 11: ...od screws provided see Figure 11 Siding standoff must sit flush against exterior fascia material 7 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before connecting ho...

Page 12: ...red NOTICE Donotsealtermination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward as this may cause excessive temperatures which could cause a...

Page 13: ...commended Applications Installations requiring a vertical rise on building exterior Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are available for i...

Page 14: ...or a horizontal system using two 90 elbows Figure 18 Horizontal Termination Configuration for Venting Using Two 90 Elbows with Termination at 90 with Fireplace 45 Elbow Venting with Two 90 Elbows Vert...

Page 15: ...ceiling is an insulated ceiling or an attic nail firestop from top side This prevents loose insula tion from falling into required clearance space If area above ceiling is a living space install fire...

Page 16: ...e 90 Elbow Vertical Round High Wind Termination Shown 45 Elbow poor draft or down drafting in high winds Increasing vent height may solve this problem 7 Twist lock vent cap onto last section of vent p...

Page 17: ...feet in the USA you may need to decrease the input rating by changing the existing burner orifice to a smaller size Re duce input 4 for each 1000 feet above sea level Check with your local gas company...

Page 18: ...Roof Flashing 0 12 6 12 26 Screws VKC 58 Corner Vent Kit Galvanized Includes 45 Elbow 7 12 Adjustable Pipe Wall Firestop Horizontal Termination 6 Pipe 90 Elbow 18 Screws HHTK 58 High Wind Round Horiz...

Page 19: ...upward Blower will fit inside back opening and be held in position against back wall by magnets see Figure 25 4 Be certain that all wire terminals are securely attached to terminals on blower motor a...

Page 20: ...hite wire to other remaining blower motor terminal Note Power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connec tions DO NOT trim e...

Page 21: ...h Fan Switch N O Green White On 110 115 V A C Blower Motor Black Off 1 2 Black Installing Gas Piping to Fireplace Location WARNING A qualified service person must connect fireplace to gas supply Follo...

Page 22: ...t trap drip leg where it is within reach for cleaning Install in piping sys tem between fuel supply and fireplace Locate sediment trap drip leg where trapped matter is not likely to freeze A sediment...

Page 23: ...es forming show a leak Correct all leaks at once 5 Reconnect fireplace and equipment shutoff valve to gas supply Check recon nected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5...

Page 24: ...d pets away from glass WARNING If fireplace has been running turn off and un plugfireplace Letcoolbeforere moving glass door or louvers Removing Louver Panels Remove top and bottom louver panels by si...

Page 25: ...with embers It is not necessary to use all of the ember material provided 2 Pour lava rock onto plenum but not onto flat burner It is not necessary to use all of the lava rock provided NOTICE Do not...

Page 26: ...C Remote Receiver Fireplace Receptacle Remote Control Receiver Extension Cord Ignition Module Plug Figure 41 Installing Battery into Back of Handset Pull to Remove Insulation Tab Battery Cover 12 Volt...

Page 27: ...www desatech com 116235 01K 27 EV2 EV1 ORANGE IGNITOR LEAD GREEN PILOT TRANSFORMER IS1070B SYNETEK CONTROLS INC 24V AC E4 E2 E3 E6 RED E8 E12 BLUE 120V AC GROUND BLACK WHITE Wiring Diagram...

Page 28: ...re or explosion may result causing property damage per sonal injury or loss of life A This appliance is equipped with an igni tion device which automatically lights the pilot Do not light pilot by han...

Page 29: ...remove adjustment screw see Troubleshooting page 31 BURNER FLAME PATTERN Burner flames will be steady not lifting or float ing Flame patterns will be different from unit to unit and will vary dependi...

Page 30: ...r to remove any carbon buildup on logs Replace log s if broken See Replacement Parts on page 34 Replace ember material periodically as needed See Replacement Parts on page 34 WARNING Turn off fireplac...

Page 31: ...the system make sure the gas shutoff valve is ON The two most common causes of a malfunctioning gas appliance are 1 Loose wiring connections 2 Construction debris clogging the pilot and or gas contro...

Page 32: ...rroded 1 Check electrical connec tions 1 Clean and adjust pilot flame for maximum flame im pingement on thermopile 2 Have vent system inspect ed including termination cap Remove any restriction or obs...

Page 33: ...of embers and pan material OBSERVED PROBLEM Gas odor even when control knob is in OFF position Gas odor during combustion Glass soots Dark residue on logs or inside of fireplace REMEDY 1 Locate and c...

Page 34: ...n Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition fireplace will not produce specified heat propane LP gas supply might be low pro pane LP units only You may feel yo...

Page 35: ...If they can not supply these accessories call DESAHeating LLC at 1 866 672 6040 for information You can also write to the address listed on the back page of this manual Brick Liner kit BL36DA Textured...

Page 36: ...www desatech com 116235 01K 36 Parts Models VC36NE VVC36NE VC36PE and VVC36PE series 6 7 22 19 20 15 2 14 21 8 1 4 13 9 16 3 18 5 17 23 10 11 12 24 25 26...

Page 37: ...m Louver Assembly 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 01 Heat Shield 1 10 116215 01 Log Set with Grate Assembly 1 11 116338 01 Right Burner Log 1 12 116339...

Page 38: ...www desatech com 116235 01K 38 7 15 10 12 3 2 13 9 23 24 22 21 11 25 27 26 29 30 28 33 32 31 6 12 14 18 17 17 18 19 20 16 14 8 4 5 1 12 PARTS burner assembly Models VC36NE VC36PE VVC36NE and VVC36PE...

Page 39: ...lectric Valve Assembly NG 1 14570 Electric Valve Assembly LP 1 12 11165 Screw 10 x 5 8 Zinc 1 13 111913 01 Burner Base Gasket 1 14 14500 Brass Fitting 2 15 116345 01 Pilot Bracket 1 16 26827 Switch Br...

Page 40: ...e not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation T...

Reviews: