www.desatech.com
116208-01G
13
INSTALLATION
Continued
Figure 9 - Installing Gas Line and
Equipment Shutoff Valve (Model May
Vary From Illustration)
Knockout
Locations
(Knock Out
One Hole)
Gas Line
Hole
Equipment
Shutoff
Valves (Install
One)
Figure 10 - Location of Knockout for
Gas Line
Knockout
Chisel
Firebrick Side Wall
Remove
this Area
Side
View
Figure 11 - Air Kit Handle Location
Air Kit
Handle
Screen
Pocket
COMBUSTION AIR kIT MODEL Ak4
(OPTIONAL)
An outside air kit may be installed on left
side of fireplace only. Vent can be installed
through any outside wall a minimum of three
feet below fireplace termination cap. Handle
to operate damper door for outside air inlet
will be located inside the left “screen pocket”
of firebox (see Figure 11). Pull handle to open
or push to close.
CAUTION: Air inlet ducts are
not to terminate in attic space.
INSTALLING FIREPLACE HOOD
AND SCREEN
1. Attach hood and front panel assembly by
snapping panel assembly into fireplace
opening (see Figure 12).
Figure 12 - Hood Placement
(Model May Vary From Illustration)
Hood