111640-01B
16
For more information, visit www.desatech.com
For more information, visit www.desatech.com
CAUTION: Do not try to adjust heating levels by
using the equipment shutoff valve.
7.
Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
• If control knob does not pop out when released, contact
a qualified service person or gas supplier for repairs.
Note:
If pilot goes out, repeat steps 3 through 7.
8.
Slightly push in and turn control knob counterclockwise
to the ON position.
9.
Set flame adjustment knob to any level between HI and LO.
Figure 30 - Pilot
Ignitor
Electrode
Pilot Burner
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Heater
1.
Turn control knob clockwise
to the OFF position.
2a. Set selector switch in the OFF position.
2b.
If Using Optional Hand-Held remote:
Set selector switch
in the OFF position to keep from draining battery.
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing one
of the following:
1.
Turn control knob clockwise
to the PILOT position.
2.
Use remote control manual OFF button.
3.
Set selector switch in the OFF position.
Ignitor
Electrode
Pilot Burner
Propane/LP Gas
Natural Gas
OPERATING HEATER
Lighting Instructions
To Turn Off Gas To Appliance
WARNING: Damper handle will be hot if heater
has been running.
1.
STOP! Read the safety information, page 15 column 2.
2.
Make sure equipment shutoff valve is fully open.
3.
Press in and turn control knob clockwise
to the
OFF position (see Figure 29).
4.
Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information, page 15. If you don’t
smell gas, go to the next step.
5.
Press in and turn control knob counterclockwise
to the PILOT position. Press in control knob for five (5)
seconds (see Figure 29).
Note:
You may be running this heater for the first time
after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.
6.
With control knob pressed in, press and release electronic
ignitor button. This will light pilot. Hold in ignitor button
until pilot lights.
Note:
If pilot does not stay lit, contact a qualified service
person or gas supplier for repairs. Until repairs are made,
light pilot with match. To light pilot with match, see Manual
Lighting Procedure, page 17.
OPERATING HEATER
Continued
WARNING:
• If fireplace has glass doors, never operate this
heater with glass doors closed. If you operate heater
with doors closed, heat buildup inside fireplace will
cause glass to burst. Make sure there are no ob-
structions across opening of fireplace.
• You must operate this heater with a fireplace screen
in place. Make sure fireplace screen is closed
before running heater.
NOTICE: During initial operation of new heater, burn-
ing logs will give off a paper-burning smell. Orange
flame will also be present. Open damper or window to
vent smell. This will only last a few hours.
LIGHTING
INSTRUCTIONS
Note:
Home owners generally prefer to operate their heater
with the chimney damper closed. This will put all the heat into
the room. However, there may be times you will desire the full
flames of the HI heat setting but will find the heat output
excessive. You can open the chimney damper (if you have one)
fully or partially to release some of the heat.
O
F
F
PIL
OT
O
N
L O
I H
Control Knob
Electronic
Ignitor Button
Flame
Adjustment Knob
Figure 29 - Control Knob and Ignitor Button Location