Desa Vanguard VMH26TNA Owner'S Operation And Installation Manual Download Page 10

10

104060

COMPACT CLASSIC HEARTH FIREPLACE

VMH26TNA

®

13"

16"

19"

21"

2 1/2"

6"

8"

10"

Note:
All vertical
measurements
are from top of
fireplace
opening to 
bottom of
mantel shelf. All
measurements
are in inches.

INSTALLATION

Continued

Figure 12 - Attaching Brass Trim to Fireplace

Shoulder
Screws

Assembled
Brass Trim

OPTIONAL MANTEL
INSTALLATION

Note:

 Refer to instructions provided with

the mantel for assembly instructions. Refer
to instructions below for system installa-
tion. Refer to instructions on page 4 for
firebox assembly. Blower accessory should
be installed if it is being used (see Accesso-
ries, 
page 27).

1.

Unscrew four brass screws that attach
top louver to fireplace. Remove louver
from fireplace and set aside.

2.

Place fireplace on wood base.

3.

Place mantel around fireplace/base
assembly.

4.

Assemble brass trim kit. See Assem-
bling Brass Trim
, page 11.

Figure 13 - Attaching Wood Base to Floor

 1 

3

/

4

" Screw

Wood
Base

Hole for 3"
wood screw for
attaching
fireplace to
wooden base

Hole for 3"
wood screw
for attaching
fireplace to
mantel

5.

Firmly snap brass trim kit on shoulder
screws. Shoulder screws are located on
fireplace cabinet (see Figure 12).

6.

Align brass trim kit for flush fit around
opening.

7.

Use two 3" wood screws provided and
attach fireplace base to wooden base
(see Figure 12).

8.

Remove brass trim kit and mantel. Be
careful not to damage wall or mantel.

9.

Place wood base next to wall at instal-
lation location.

10. Attach wood base to floor with two 1 

3

/

4

"

black screws provided (see Figure 13). If
the floor is concrete use anchor method
(see Attaching Wood Base to Solid Floor,
page 14).

Mantel Clearances for Built-In
Installation

If placing mantel above built-in fireplace,
you must meet minimum clearance between
mantel shelf and top of fireplace opening.

If your installation does not meet the above
minimum clearances, you must:

• raise the mantel to an acceptable height,

OR

• remove the mantel.

Figure 11 - Minimum Mantel Clearances
for Built-In Installation

Mantel Shelf

Side of
Firebox

11. Install gas line. See Connecting To Gas

Supply, page 14.

12. Check for leaks. See Checking Gas

Connections, page 16.

13. Place mantel around fireplace. Be care-

ful not to damage wall or mantel.

14. Place brass trim kit on the shoulder

screws located on the side and top of
the fireplace. Firmly snap the brass trim
over the shoulder screws on fireplace
(see Figure 12).

15. Adjust assembly to remove any gaps.

Attach remaining two 3" wood screws
from hardware pack through openings
inside of fireplace sides into the man-
tel. The openings are located at top be-
hind the area for the brass louvers (see
Figure 13).

16. Reinstall top brass louvers.

Summary of Contents for Vanguard VMH26TNA

Page 1: ...partment Installation and service must be per formed by a qualified installer service agency or the gas supplier WARNING Improper installa tion adjustment alteration ser vice ormaintenancecancause inj...

Page 2: ...l into the control area of fireplace 7 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is in place before run ning fireplace 8 This fireplace is designed...

Page 3: ...packet 4 Check fireplace for any shipping damage If fireplace is damaged promptly inform dealer where you bought fireplace PRODUCT FEATURES SAFETY PILOT This fireplace has a pilot with an Oxygen Depl...

Page 4: ...er now Follow installation in structions provided with blower 5 Gently place back log on burner sup port see Figure 2 The log should fit flat against top of burner support Place two 10 one inch long s...

Page 5: ...kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to areas such as joints around wi...

Page 6: ...dd the Btu Hr of all fuel burning appliances in the space Vent free fireplace __________________Btu Hr Gas water heater __________________Btu Hr Gas furnace __________________Btu Hr Vented gas heater...

Page 7: ...Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Figure 4 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building Thisfre...

Page 8: ...ough open ings to create the easiest installation see Built In Fireplace Installation page 9 CHECK GAS TYPE Use only natural gas If your gas supply is not natural gas do not install fireplace Call dea...

Page 9: ...se dimen sions shown in Figure 8 for the rough opening If installing in a corner use dimensions shown in Figure 9 for the rough open ing The height is 26 7 8 which is the same as the wall opening abov...

Page 10: ...two 3 wood screws provided and attach fireplace base to wooden base see Figure 12 8 Remove brass trim kit and mantel Be careful not to damage wall or mantel 9 Place wood base next to wall at instal la...

Page 11: ...er Louver Assembly Upper Louver Assembly Brass Screws Blower Bracket Mounting Holes 1 2 Remove Screw Valve Cover Shield Shoulder Screw Removing Valve Cover Shield 1 Open bottom louver assembly by swin...

Page 12: ...rear of the valve cover shield and through the rectangular hole in the front of shield see Figure 17 8 Reconnect red wire to switch position 3 Reconnect blue wire to switch posi tion 1 Reconnect gree...

Page 13: ...rd ware kit into one of the holes found on rear of valve cover shield The other hole is for a strain relief clamp not supplied to secure incoming electrical supply 2 Follow steps 2 through 6 in Instal...

Page 14: ...monly known as wellhead gas CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 or greater diameter to al...

Page 15: ...exible gas line is provided to allow accessibility fromthefireplace seeFigure23 The flexible gas supply line con nection to the manual shutoff valve should be accessible Flexible Gas Line from Firepla...

Page 16: ...dual manual shutoff valve from gas supply piping system Pressures in excess of 1 2 psig will damage fireplace regulator 2 Cap off open end of gas pipe where manual shutoff valve was connected 3 Pressu...

Page 17: ...iedservicetechniciantoinspect the appliance and to replace any part of the control system and any gas con trol which has been under water Control Knob WARNING You must operate this fireplace with the...

Page 18: ...ll shut off The burner willcyclebackonwhenroomtemperature drops below the set temperature The control knob can be set to any heat level between HI and LO Note The thermostat sensing bulb mea sures the...

Page 19: ...attern WARNING If yellow tipping occurs your fireplace could pro duce increased levels of carbon monoxide If burner flame pattern shows yellow tipping follow in structions at bottom of this page Yello...

Page 20: ...1 Turn on gas supply or open manual shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down control knob Re peatignitingoperationun...

Page 21: ...oblem will stop after a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local natural ga...

Page 22: ...tatement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Not enough combustion ventilation air OBSERVED PROB...

Page 23: ...ore or home center may carry com pressed air in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the direc tions on the can If you don t follow d...

Page 24: ...HEARTH FIREPLACE VMH26TNA ILLUSTRATED PARTS BREAKDOWN VMH26TNA 12 1 12 2 23 29 43 32 36 38 13 7 8 33 43 11 10 27 4 7 30 1 3 2 9 17 19 6 22 31 21 41 26 42 39 40 16 15 18 24 28 5 34 25 20 35 1 4 35 2 12...

Page 25: ...303 02 Regulator Screw 2 19 104335 01CK Outer Shell Base 1 20 102649 01CJ Branch Support 1 21 099415 10 Gas Regulator 1 22 102875 01 Regulator Bracket 1 23 101381 01 Valve Cover and Piezo 1 24 099387...

Page 26: ...national have ready model number of your fireplace the replacement part number SPECIFICATIONS Btu Variable 14 000 26 000 Type Gas Natural Only Ignition Piezo Pressure Regulator Setting 3 W C Inlet Gas...

Page 27: ...stain or paint Complete assembly instructions in cluded Three sided brass trim kit included CABINET MANTEL WITH BUILT IN HEARTH BASE Unfinished GM923U Finished GM922F For use with fireplace A hardwood...

Page 28: ...scausedbyimproperinstallation Travel diagnosticcost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner TO THE FULL...