background image

8

107050

VENTED TYPE DECORATIVE APPLIANCE

EVGL850N

®

INSTALLATION

OPTIONAL REMOTE
CONTROL INSTALLATION
(Model WRC)

Note:

 If using optional wireless hand-held

remote control, the wall switch must be in
the ON position to be operational. The re-
mote control then becomes the switching
mechanism for fireplace operation.

1.

The WRC model receiver does not re-
quire a battery. The receiver can be in-
stalled by first plugging the short ex-
tension cord into the fireplace recep-
tacle. Then plug the receiver unit into
the extension cord. Finally plug the ig-
nition module plug into the receiver unit
(see Figure 12).

2.

Activate the remote handset battery by
removing the insulating tab on the back
of the handset (see Figure 13). The bat-
tery is included pre-installed.

3.

Once the battery is activated the unit is
ready to use.

WALL SWITCH
INSTALLATION (EVGL850N)

The installation of a wall switch allows you
to activate the gas control valve and turn the
fireplace on and off. The wall switch is to be
connected to the incoming 120 volt regular
household wiring that supplies the electric-
ity to the fireplace. Refer to wiring diagram
in this manual on page 14.

Figure 13 - Installing Battery into Back of Handset

Pull to Remove
Insulation Tab

Battery Cover

12 Volt Battery

Figure 12 - Installing the WRC Remote Receiver

Fireplace
Receptacle

Remote Control
Receiver

Extension Cord

Ignition Module Plug

Back of Handset

Summary of Contents for Vanguard EVGL850N

Page 1: ...ediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed...

Page 2: ...572mm 9 5 8 244mm 27 686mm 10 3 4 273mm Left Side 9 3 4 248mm Right Side 13 330mm 2 3 8 60mm 32 813mm 33 13 16 859mm HEARTH AREA DIMENSIONS TOP VIEW FRONT VIEW RIGHT SIDE VIEW FRONT INSIDE VIEW Figur...

Page 3: ...MAY CAUSE A FIRE HAZARD The DESA warranty will be voided by and DESA disclaims any responsibility for the following actions A Modification of the appliance or any of the components B Use of any compo...

Page 4: ...e yondanoutsidewall thiswouldalsoreduce the cutting of joists roof rafters and such Check local codes for any restrictions Projected installations can extend any distance into the room A projection ma...

Page 5: ...iance see Figure 15 page 9 Figure 7 Rough Opening for Installing in Wall Figure 8 Rough Opening for Corner Installation 41 7 8 1061mm 15 381mm 36 1 4 921mm 59 1 4 1505mm 29 5 8 752mm 21 3 16 538mm COR...

Page 6: ...l vertical system height Codes also allows only one offset in the total system when at 60 de grees or greater The total vertical height in thisexamplerepresentstheminimumheight of 8 feet and therefore...

Page 7: ...struc tion see Figure 10 VENTING INSTALLATION Continued If venting horizontally through a side wall becomes necessary a listed thimble ap proved for use with B type vent must be used Check with your l...

Page 8: ...e 12 2 Activate the remote handset battery by removing the insulating tab on the back of the handset see Figure 13 The bat tery is included pre installed 3 Once the battery is activated the unit is re...

Page 9: ...lack iron gas line be routed from the gas source through a sediment trap shown in Figure 16 and into the appliance Once connected through the appliance a flexible gas line may be used for ease of inst...

Page 10: ...log piece into the notches on the right side of the front and rear logs see Figure 23 NOTICE Do not put lava rock on burner or under burner Placing lava rock on burner could cause performance problems...

Page 11: ...dividuals Ifthisisthecase pleaserequest help from someone else CAUTION For use with glass doorscertifiedwiththeappliance only CAUTION Do not operate theappliancewiththeglassdoor removed WARNING Childr...

Page 12: ...call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier call the fire department C Do not use this appliance if any part has been...

Page 13: ...l not require such purging 1 When lit for the first time the appli ance will emit a slight odor for an hour or two This is due to the curing of the logs and burn in of internal paints and lubricants u...

Page 14: ...ne LP gas supply may be low When Gas Quality Is Bad pilot will not stay lit burner will produce flames and soot fireplace will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad...

Page 15: ...imes to purge all air out of lines If after re peated attempts appliance does not light call for qualified service and repair 3 Remove debris and dirt inspect and clean any other possible obstructions...

Page 16: ...page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak SeeWarning statement at top of page 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner f...

Page 17: ...inal replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contactauthorizeddealersofthisproduct If theycan tsupplyoriginalreplacementpart s...

Page 18: ...FIXED GLASS DOORS 01605 105863 01 IGNITION MODULE 14301 107221 01 TRANSFORMER 14129 107222 01 PILOT ASSEMBLY Natural Electronic 27197 107220 01 If in need of replacing have a qualified technician repl...

Page 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 20: ...e the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES A...

Reviews: