background image

www.desatech.com

116647-01B

8

VENTING INSTallaTION 

INSTRUCTIONS

NOTICE:  Read  these  instruc

-

tions  completely  before  at

-

tempting installation.

These models are tested and approved for use 

with DESA (direct-vent) pipe components and 

terminations.

The venting system must terminate on the outside of 

the structure and can not be attached to a chimney 

or flue system serving a separate solid fuel or gas 

burning appliance. A direct-vent appliance must 

have its own venting system. DO NOT common 

vent this appliance.

These models are approved to be vented either 

horizontally through an outside wall or vertically 

through a roof or chase enclosure using the fol-

lowing guidelines:

•  When venting system terminates horizontally 

on an outside wall, you may install a standoff 

if the termination cap is to be installed directly 

on a combustible finish such as vinyl, wood, 

stucco, etc.

•  Never  run  the  vent  downward  as  this  may 

cause  excessive  temperatures  which  could 

cause a fire.

•  Vent pipe air space clearances to combustibles 

are 1" on all sides except on the horizontal 

sections, which requires 2" clearance from 

the top of the pipe. Where the termination cap 

penetrates a combustible wall, 1" air space 

clearance is required.

•  Snorkel terminations are required when minimum 

clearance to grade cannot be met (see Figure 16 

on page 12).

•  Have fireplace and selected vent components on 

hand to help determine the exact measurements 

when elbowing or offsetting. Always use wall 

firestops when penetrating walls and firestops 

when penetrating ceilings or attic spaces.

•  Install horizontal venting with a 1/4" rise for 

every 12" of run toward the termination.

 WARNING: Read all instruc-

tions completely and thoroughly 

before  attempting  installation. 

Failure to do so could result in 

serious injury, property damage 

or loss of life.

NOTICE: Failure to follow these in

-

structions will void the warranty.

ImportaNt:

 Do not seal vent cap to pipe. Cap 

must be removable for service.

INSTALLATION PRECAUTIONS

•  Wear gloves and safety glasses for protection

•  Use extreme caution when using ladders or 

when on roof tops

•  Be aware of electrical wiring locations in 

walls and ceilings

The following actions will void the warranty on 

your venting system:

•  Installation  of  any  damaged  venting 

component

•  Unauthorized modification of the venting sys-

tem (Do not cut or alter vent components)

•  Installation  of  any  component  part  not 

manufactured or approved by DESA

•  Installation other than as instructed by these 

instructions

 WARNING: This gas fireplace 

and  vent  assembly  must  be 

vented  directly  to  the  outside. 

The venting system must NEVER 

be attached to a chimney serv

-

ing a separate solid fuel burning 

appliance. Each direct-vent gas 

appliance must use a separate 

vent  system.  Do  not  use  com

-

mon vent systems.

  WARNING:  Vent  pipe  air 

space clearances to combustibles 

are 1" on all sides except on the 

horizontal sections, which require 

2" clearances from the top of the 

pipe. Where the termination cap 

penetrates a combustible wall, 1" 

air space clearance is required.

Summary of Contents for (V)T32EN-A Series, (V)T32EP-A

Page 1: ...damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to ligh...

Page 2: ...fety Information Table of Contents Safety Information 2 Product Identification 4 Local Codes 4 Product Features 4 Pre Installation Preparation 5 Location of Termination Cap 7 Venting Installation Inst...

Page 3: ...lid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fire place name plate Carefully supervise young chil dren when they are in the room with fireplace SAFETY I...

Page 4: ...rner Assembly Local Codes Install and use fireplace with care Follow all local codes In the absence to local codes use the cur rent National Fuel Gas Code ANSI Z223 1 NFPA 54 USA or the current CSA B1...

Page 5: ...fireplace except where standoff spacers are integrally attached If standoff spacers are attached to your fireplace these spacers can be placed directly against wall or framing material See framing det...

Page 6: ...ll minimum clearances must be met For available accessories for this fireplace see Accessories on page 33 If you are using a separate combustible mantel piece refer to Figure 6 for proper installation...

Page 7: ...minimum L clearance above paved side walk or a paved driveway located on public property 84 inches 213 3cm minimum M clearance under veranda porch deck 12 inches 30 5cm minimum N clearance above a ro...

Page 8: ...asurements when elbowing or offsetting Always use wall firestops when penetrating walls and firestops when penetrating ceilings or attic spaces Install horizontal venting with a 1 4 rise for every 12...

Page 9: ...t one section clockwise approximately one quar ter turn until the sections are fully locked see Figure 8 Note Horizontal runs of vent must be supported every three feet Use wall straps for this purpos...

Page 10: ...against the exterior fascia material 7 Combustible Exterior Wall Only Slidethewall firestop over the vent pipe before connecting horizontal run to vent cap see Figure 12 8 Carefully move fireplace wit...

Page 11: ...UST be met IMPORTANT Remember that a horizontal run of venting must have a 1 4 rise for every 12 of run toward the termination WARNING Never run vent downward as this may cause excessive temperatures...

Page 12: ...oor installation where pipe vents horizontally through wall over 12 horizontal pipe Basement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATI...

Page 13: ...guration for Venting Using Two 90 Elbows Venting with Two 90 Elbows Horizontal H1 Vertical V Horizontal H1 Horizontal H2 5 min 2 max 6 max 6 min 4 max 12 max 7 min 6 max 18 max 8 min 8 max 20 max 20 m...

Page 14: ...alling into the required clearance space Otherwise install firestop below the framed hole The firestop should be installed with no less than three nails per side see Figure 20 2 Assemble the desired l...

Page 15: ...res 21 through 24 show four different con figurations for vertical termination Venting Installation instructions Continued Figure 21 Vertical Venting Configuration Using Two 90 Elbows with Two Horizon...

Page 16: ...Department at 1 866 672 6040 parts list for venting kits and components DESA 5 8 Pipe Vent Kits Number Description P58 6 6 Section Double Wall Pipe Galvanized P58 12 12 Section Double Wall Pipe Galvan...

Page 17: ...Installation CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing If your gas supply is not correct do not install fireplace See retailer where you purchased the fireplace for...

Page 18: ...n blower wheel Turn blower on and check for operation Turn blower off by turning knob fully counterclock wise before continuing 10 Peel off the backing paper and stick the sup plied wiring diagram dec...

Page 19: ...ordingly 8 Turn on power to duplex outlet if previ ously turned off per the warning in column 2 page 17 9 Plug in blower power cord to duplex outlet 10 Theblowerwillonlyrunwhenthespeedcontrol knobisin...

Page 20: ...gas pressure to between 11 and 14 inches of water If you do not reduce incoming gas pressure fireplace regulator damage could occur Install external regulator with the vent pointing down as shown in...

Page 21: ...access holes on side of fireplace 3 Attach flexible gas line from gas supply to control valve see Figure 32 4 Check all gas connections for leaks See Checking Gas Connections Fireplace Installation C...

Page 22: ...ive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once 5 Light fireplace see Operating Fireplace page 23 Check all other internal joints for leaks 6 Turnofffirepl...

Page 23: ...e 37 Removing Replacing Glass Door Lock Unlock Glass Frame Assembly Screw Hinge Latch 6 Replace screen rod assembly by reversing step 1 7 Replace louvers by reversing procedure under Removing Louver P...

Page 24: ...r latches and open glass door See steps 1 and 2 of Remov ing Glass Door page 23 Install logs according to instructions for fireplace model numbers 1 Place log 1 rear log on top of grate Make sure the...

Page 25: ...andset Battery Cover 12 Volt Battery Back of Handset Pull to Remove Insulation Tab WALL SWITCH INSTALLATION The installation of a wall switch allows you to ac tivate the gas control valve and turn the...

Page 26: ...your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Do not use this appliance if any part has been under...

Page 27: ...t be purchased separately see Accessories page 33 Follow installation instructions on page 25 1 Turn equipment shutoff valve to ON position You can now turn the burner on and off with the hand held re...

Page 28: ...e 30 Figure 51 Typical Flame Pattern Cleaning and Maintenance WARNING Turn off fireplace and let cool before cleaning CAUTION You must keep control areas burners and circulating air passageways of fir...

Page 29: ...ntrols should be cleaned with compressed air to remove dust dirt or lint Use a vacuum cleaner or small soft bristled brush to remove excess dust dirt or lint logs If you remove logs for cleaning refer...

Page 30: ...on mod ule 2 Pilot flame too low to sense REMEDY 1 Check to see if you have gas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure sev eral times to purge all air out of lin...

Page 31: ...Gas Connections page 21 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Checking Gas Connec tions page 21 1 Adjust the log set so that the...

Page 32: ...ll DESA s Technical Service Department at 1 866 672 6040 When calling DESA have ready your name your address model and serial numbers of your fireplace how fireplace was malfunctioning type of gas use...

Page 33: ...s Black Louver trim kit Rolled Louvers Only Not Shown LT32B Rolled Louver Trim Kit Brushed Brass LT32P Rolled Louver Trim Kit Platinum LT32PB Rolled Louver Trim Kit Polished Brass Deflection hoods Not...

Page 34: ...647 01B 34 illustrated Parts Breakdown Models V T32EN A V T32ENB A V T32ENR A V T32ENRB A V T32EP A V T32EPB A V T32EPR A V T32EPRB A 6 7 21 18 19 10 13 2 12 20 8 11 1 14 9 17 3 15 4 16 5 16 22 2 22 6...

Page 35: ...108890 01 108890 01 Burner Base Gasket 1 11 109082 03 109082 03 Heat Shield 1 12 108897 01 108897 01 Rear Refractory Brick Panel B Models Only 1 13 108901 01 108901 01 Right Refractory Brick Panel B...

Page 36: ...GN D P V M V T R TH M V 21 23 24 26 25 27 17 22 16 14 20 12 9 8 10 13 15 19 18 28 29 11 2 1 7 3 5 4 6 illustrated parts breakdown BurnER Assembly Models V T32EN A V T32ENB A V T32ENR A V T32ENRB A V T...

Page 37: ...25 Orifice 47 Natural 1 14514 Orifice 55 Propane LP 1 16 14528 Brass Elbow Fitting 1 17 108863 01 Supply Connect Plug 1 18 23416 Electronic Components Board 1 19 14129 Transformer 1 20 11147 Screw 10...

Page 38: ...____ _____________________________________________________ _____________________________________________________ _____________________________________________________ _________________________________...

Page 39: ...____ _____________________________________________________ _____________________________________________________ _____________________________________________________ _________________________________...

Page 40: ...tation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENTALLOWED BYTHE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF...

Reviews: