Figure 13 - Typical Horizontal
Termination Cap Mounting with
Additional Siding Standoff Installed
Siding
Standoff
Screws
High Wind
Termination
Apply
Mastic to
Outside
Edge of
Standoff
Exterior Wall
with Vinyl
Siding
10
3
/
4
" x 10
3
/
4
"
Framed
Opening
Maintain 1"
Minimum Air
Space Around
Outer Pipe When
Penetrating a
Wall
Minimum Pipe
Overlap 1
1
/
4
"
Wall
Firestop
Direct
Vent
Pipe
VENTING INSTallaTION
INSTRUCTIONS
Continued
Horizontal Termination Configurations
Figures 14 through 18 show different configura-
tions and alternatives for venting with horizontal
termination. Each figure includes a chart with
critical minimum and maximum dimensions which
MUST be met.
ImportaNt:
Remember that a
horizontal run of venting must have a 1/4" rise for
every 12" of run toward the termination.
WARNING: Never run vent
downward as this may cause
excessive temperatures which
could cause a fire. Operation of
improperly installed and main
-
tained venting system could
result in serious injury, property
damage or loss of life.
Vertical (V) Horizontal (H)
9
3
/
4
"
17" max.
Horizontal High
Wind Square
Termination
Wall
Firestop
45° Elbow
Figure 14 - Horizontal Termination
Configuration for Square or Round
Termination
45° Elbow
Wall
Firestop
Horizontal
Round
Termination
Exterior
Portion of Wall
Firestop (Round
Termination Only)
GROUND FLOOR INSTALLATION
Recommended Applications:
• Installation using cabinet surrounds
• Through the wall using round or square termi-
nation (up to 12" horizontal pipe)
• NOT FOR CORNER INSTALLATION
Adjustable
Pipe 1"
Max.
Square Termination