VENTING INSTALLATION 

INSTRUCTIONS

NOTICE:  Read  these  instruc-

tions  completely  before  at

-

tempting installation.

These models are tested and approved for use 

with DESA (direct-vent) pipe components and 

terminations.

The venting system must terminate on the outside of 

the structure and can not be attached to a chimney 

or flue system serving a separate solid fuel or gas 

burning appliance. A direct-vent appliance must 

have its own venting system. DO NOT common 

vent this appliance.

These models are approved to be vented either 

horizontally through an outside wall or vertically 

through a roof or chase enclosure using the fol

-

lowing guidelines:

•  When venting system terminates horizontally 

on an outside wall, you may install a standoff 

if the termination cap is to be installed directly 

on a combustible finish such as vinyl, wood, 

stucco, etc.

•  Never  run  the  vent  downward  as  this  may 

cause  excessive  temperatures  which  could 

cause a fire.

•  Vent pipe air space clearances to combustibles 

are 1" on all sides except on the horizontal 

sections, which requires 2" clearance from 

the top of the pipe. Where the termination cap 

penetrates a combustible wall, 1" air space 

clearance is required.

•  Snorkel  terminations  are  required  when 

minimum clearance to grade cannot be met (see 

Figure 16 on page 13).

•  Have fireplace and selected vent components on 

hand to help determine the exact measurements 

when elbowing or offsetting. Always use wall 

firestops when penetrating walls and firestops 

when penetrating ceilings or attic spaces.

•  If using a venting configuration of only hori

-

zontal venting with no vertical run, a 1/4" rise 

for every 12" of run toward the termination is 

required.

•  For installation of fireplace at elevations of 4000 

feet or greater, pay special attention to venting 

requirement recommendations.

 WARNING: Read all instruc-

tions completely and thoroughly 

before  attempting  installation. 

Failure to do so could result in 

serious injury, property damage 

or loss of life. 

NOTICE: Failure to follow these in-

structions will void the warranty. 

NOTICE: Do not seal termination 

cap to vent pipe. Cap must be 

removable  for  vent  inspection 

and maintenance.

INSTALLATION pRECAUTIONS

•  Wear gloves and safety glasses for protection

•  Use extreme caution when using ladders or 

when on roof tops

•  Be aware of electrical wiring locations in walls 

and ceilings

The following actions will void the warranty on 

your venting system:

•  Installation of any damaged venting component

•  Unauthorized modification of the venting sys

-

tem (Do not cut or alter vent components)

•  Installation of any component part not manu

-

factured or approved by DESA

•  Installation other than as instructed by these 

instructions

 WARNING: This gas fireplace 

and vent assembly must be vented 

directly to the outside. The venting 

system must NEVER be attached 

to a chimney serving a separate 

solid fuel burning appliance. Each 

direct-vent  gas  appliance  must 

use a separate vent system. Do not 

use common vent systems.

  WARNING:  Vent  pipe  air 

space clearances to combustibles 

are 1" on all sides except on the 

horizontal sections, which require 

2" clearances from the top of the 

pipe. Where the termination cap 

penetrates a combustible wall, 1" 

air space clearance is required.

Summary of Contents for (V)KV36N Series

Page 1: ...o not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier...

Page 2: ...vice agency or the gas supplier This appliance may be in stalled in an aftermarket permanently located manufactured mobile home where not prohib ited by local codes This appliance is only for use with...

Page 3: ...s controls can be dangerous Do not modify this fireplace under any circum stances Any parts removed for servicingmustbereplacedprior to operating fireplace WARNING Donotuseablow er insert heat exchang...

Page 4: ...ny solid fuels wood coal paper cardboard etc in this fireplace Use only the gas type indicated on fireplace nameplate 8 This appliance when installed must be electri cally grounded in accordance with...

Page 5: ...d above Pre Installation Preparation Location and space requirements Determine the safest and most efficient location for your DESA direct vent fireplace Make sure that rafters and wall studs are not...

Page 6: ...ening 42 Front 36 Top of Standoffs 0 Vent S e e v e n t i n g instructions for specific venting clearances Combustible material with a maximum thick ness of 5 8 may be flush with the top front of fire...

Page 7: ...Figure 5 Framing Clearances for Corner Installation Ref Mantel Depth Ref Mantel from Top of Louver Opening 1 14 A 16 2 12 B 14 3 10 C 12 4 8 D 10 5 6 E 8 6 4 F 6 7 2 G 4 Figure 6 Clearances for Combus...

Page 8: ...S if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L...

Page 9: ...hen penetrating ceilings or attic spaces If using a venting configuration of only hori zontal venting with no vertical run a 1 4 rise for every 12 of run toward the termination is required For install...

Page 10: ...sections together and twist one section clockwise approximately one quarter turn until the sections are fully locked see Figure 8 Note Horizontal runs of vent must be supported every three feet Use wa...

Page 11: ...eriorwallwithwoodscrewsprovided see Figure 11 The siding standoff must sit flush against the exterior fascia material 7 Combustible Exterior Wall Only Slidethewall firestop over the vent pipe before c...

Page 12: ...required NOTICE Donotsealtermination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward as this may cause excessive temperatures which could ca...

Page 13: ...in None 30 max 54 1 2 min 1 ft 48 max 66 1 2 min 2 ft 60 max 78 1 2 min 3 ft 84 max 90 1 2 min 4 ft 20 max Ground Floor Corner Venting Not to Exceed H Limits SNORKEL TERMINATION INSTALLATION Recommend...

Page 14: ...n Configuration for Venting Using Two 90 Elbows 45 Elbow HORIZONTAL SYSTEM INSTALLATION USING TWO 90 ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal sy...

Page 15: ...above the ceiling is an insulated ceiling or an attic nail firestop from the top side This prevents loose insula tion from falling into the required clearance space Of the area above the ceiling is a...

Page 16: ...irst floor including storage spaces and closets you must enclose pipe You may frame and sheetrock the enclosure with standard construction material Make sure and meet the minimum allowable clearances...

Page 17: ...om0 2000feet USA and elevations from 0 4500 feet Canada Fireplaces for High Altitude models ending in HA are for installation above 4000 feet only These fireplaces are equipped with parts specific for...

Page 18: ...Elbow 7 12 Adjustable Pipe Flue Restrictor Vertical High Wind Termination 2 Pipe 4 Pipe Wall Firestop Storm Collar Roof Flashing 0 12 6 12 26 Screws VKC 58 Corner Vent Kit Galvanized Includes 45 Elbow...

Page 19: ...blower will fit inside the back opening and be held in position against the back wall by the magnets see Figure 26 4 Be certain that all wire terminals are securely attached to terminals on blower mot...

Page 20: ...switch and the white wire to the other remaining blower motor terminal Note The power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all c...

Page 21: ...Variable Fan Switch Fan Switch N O Green White On 110 115 V A C Blower Motor Black Off 1 2 Black Installing Gas Piping to Fireplace Location WARNING A qualified service person must connect fireplace...

Page 22: ...ap drip leg in supply line as shown in Figure 32 Lo cate sediment trap drip leg where it is within reach for cleaning Install in piping system between fuel supply and fireplace Locate sediment trap dr...

Page 23: ...eplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive leak detection fluid t...

Page 24: ...hown the switch will not work 2 Route the 25 ft wire through openings pro vided on the sides of the burner system to a convenient location to mount your switch 3 Connect one bare wire end to each of t...

Page 25: ...Removing Louver Panels Remove the top and bottom louver panels by si multaneously pulling both top end spring latches towards the center of the appliance until they are disengaged from the locating ho...

Page 26: ...f the ember material provided 2 Pour lava rock onto plenum but not onto flat burner It is not necessary to use all of the lava rock provided NOTICE Do not put lava rock on burner or under burner Placi...

Page 27: ...which automatically lights the pilot Do not light pilot by hand B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air an...

Page 28: ...1 Turn gas control knob clockwise to the PILOT position 2 Set selector switch in the OFF position MANUAL LIGHTING PROCEDURE 1 Remove glass door see Removing Replacing Glass Door page 25 2 Follow steps...

Page 29: ...emperature by pressing the TEMP or buttons 4 Press the POWER and LOCK buttons together to turn off the fireplace Note Do not leave the hand held remote in the AUTO mode close to the fireplace The radi...

Page 30: ...wer have an ON setting and an OFF setting The blower will only run when the switch is in the ON position In the OFF position the blower will not operate OPERATIng fireplace Continued Note for BKT Only...

Page 31: ...erate fireplace with the glass doorunlatched removed cracked or broken WARNING Do not use abra sivecleanersasthismaydamage glass Use a nonabrasive house holdglasscleanertocleanglass Do not clean glass...

Page 32: ...se a vacuum cleaner to remove any carbon buildup on logs Replace log s if broken See Replacement Parts on page 37 Replace ember material periodically as needed See Replacement Parts on page 37 venting...

Page 33: ...in stalled 5 Depleted gas supply propane LP models only 6 Pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubi...

Page 34: ...2 Clean burner see Cleaning and Maintenance page 31 or replace burner orifice 1 Clean burner see Cleaning and Maintenance page 31 or replace burner orifice 2 Replace damaged burner 3 Replace gas contr...

Page 35: ...at the base of the burner by removing log grate assembly to see that it is NOT packed with any type of material see Installing Brick Liner Models BL42DA SA and BL42DHA SA page 26 for log grate removal...

Page 36: ...pan material OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas odor during combustion Dark residue on logs or inside...

Page 37: ...w propane LP units only You may feel your gas pressure is too low If so contact your local gas supplier Technical Service You may have further questions about installation operation or troubleshooting...

Page 38: ...www desatech com 116239 01G 38 Illustrated Parts Breakdown Models KC42N VKC42N KC42P and VKC42P Series 6 7 20 17 18 13 2 12 19 8 1 4 24 11 9 14 3 16 5 15 21 10 23 22...

Page 39: ...ver Assembly 1 5 108331 02 Bottom Louver Assembly 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 01 Heat Shield 1 10 116542 01 Burner Assembly Natural Gas See page 40...

Page 40: ...desatech com 116239 01G 40 illustrated parts breakdown Burner assembly for models KC42N VKC42N KC42P AND VKC42P Series 7 15 10 12 1 12 2 3 13 9 11 21 22 TPTH TP TH 6 12 14 18 17 17 18 19 20 16 14 8 4...

Page 41: ...Line 1 10 108084 02 Pilot Assembly Natural Gas 1 108084 03 Pilot Assembly Propane LP Gas 1 108084 05 Pilot Assembly HA Models 1 11 14389 Natural Gas Valve 1 14390 Propane LP Gas Valve 1 117370 01 Nat...

Page 42: ...ector CIK Not Shown For all models Propane natural gas conversion kit Not Shown IMPORTANT NOT to be used for High Altitude HA Models PCDM 42KC Propane LP Gas NCDM 42KC Natural Gas filigree Face Louver...

Page 43: ...the fireplace to be turned on and off conveniently A wall mounted docking station is included Wall mounted thermostat control kit gwmt1 Not Shown Allows easy wall access for thermostatic operation of...

Page 44: ...ty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original cond...

Reviews: