INSTALLING
Continued
INSTALLATION CLEARANCES
Note: Clearances
are the same if
using optional
cabinet mantel or
built-in installation.
WARNING ICON
G 001
WARNING
Maintain the minimum clearances. If you can, pro-
vide greater clearances from floor, ceiling, and
adjoining wall.
Continued
MINIMUM CLEARANCE
Side Wall - 16 " Standard Mantel
Ceiling - 42" Corner Mantel
Floor - 0"
Carefully follow the instructions below. This will ensure safe installation.
Minimum Wall and Ceiling Clearances (see Figure 7)
A. Clearances from the side of the fireplace opening to any combustible wall should
not be less than 16 inches for a standard mantel or 12 inches for a corner installation.
B. Clearances from the top of the fireplace opening to the ceiling should not be
less than 42 inches.
Note:
The instructions below show installation using the cabinet mantel and the
G3000F/G3001U hearth base accessories. The hearth base accessory shown is
optional for this installation. You can install fireplace and cabinet mantel directly
on the floor. The corner mantel and face mantel accessories cannot be installed with
the G3000F/G3001U hearth base. You must install corner mantel directly on the
floor. If mounting fireplace to floor or using face mantel or corner mantel, an
optional G3005 Slim Base kit may be installed.
1. Assemble cabinet mantel, hearth base, and trim accessories. Assembly instruc-
tions are included with each accessory.
WARNING ICON
G 001
WARNING
For conventional installation, it is recommended
you use the cabinet mantel, corner mantel, or hearth
base specified in this manual. Surface clearances
may not be sufficient with other cabinet mantels
and hearth bases. This may create a fire hazard. See
Accessories, pages 32 and 33 for correct cabinet
mantel and hearth base.
CONVENTIONAL FIREPLACE INSTALLATION
Conventional installation of this fireplace involves installing fireplace along with the
corner mantel accessory or cabinet mantel with hearth base accessories against a wall
in your home. Follow the instructions below to install the fireplace in this manner.
Figure 7 - Minimum Clearance to Wall and Ceiling
,,,,,
,,,,,
,,,,,
,,,,,
,,,,,
QQQQQ
QQQQQ
QQQQQ
QQQQQ
QQQQQ
¢¢¢¢¢
¢¢¢¢¢
¢¢¢¢¢
¢¢¢¢¢
¢¢¢¢¢
42"
16"
Face or
Cabinet
Mantel
Corner
Mantel
12"