background image

701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 410-9004
www.desatech.com

55173
Rev. G
07/06

LIMITED 2-yEAR WARRANTy

DESA warrants this gas appliance to be free from the defects in material or workmanship at the time of manufacture.

REMEDy AND EXCLUSIONS

The coverage of this warranty is limited to all components of the gas appliance manufactured by DESA, with the 

exception of glass and refractory. The glass is warranted for 90 days. There will be no cost for replacement of glass 

within 90 days of installation, provided that breakage is due to heat from the appliance. We do not warranty breakage 

occurring during installation or transportation.

If the decorative gas appliance covered by this warranty is found to be defective within one year from the date of installation, 

DESA will, at its option, replace or repair defective components of the decorative gas appliance manufactured by DESA 

at no charge or will pay for reasonable costs incurred in replacing or repairing such components. These charges should be 

pre-approved by DESA before any work is done. During the second year of the warranty, DESA shall supply replacement 

parts, if readily available, at the current minimum wholesale price. DESA will not be responsible for any other expense.

REFRACTORy WARRANTy

FIRST YEAR:

 DESA warrants the refractory (except the hairline cracks less than 1/16” in width) one year from the 

date of manufacture to be free from defect in material and workmanship. If the original owner of a DESA fireplace 

believes that any of the refractory parts have failed during the above one year period, the current owner should notify 

the nearest  (DESA) distributor or dealer.  DESA will pay for the refractory replacement and reasonable labor charges.  

DESA will be responsible for the freight charges.   

SECOND YEAR:

 DESA will supply the refractory replacement parts at the current list price that is in effect at time 

of the replacement.  DESA will assume no responsibility for any labor and freight charges incurred.

This warranty covers only parts and labor as provided above. In no case shall DESA be responsible for materials, 

components or construction which are not manufactured or supplied by DESA. DESA will not be responsible for any 

labor charges to remove such materials, components or construction. All replacement parts will be shipped. F.O.B., 

Santa Ana, to purchasers’ address or the nearest DESA distributor.

QUALIFICATIONS TO THE WARRANTy

The decorative gas appliance warranty outlined above is further subject to the following qualifications:

1.  The gas appliance must be installed as per the DESA installation instructions and local building codes. The use of 

components manufactured by others with this DESA gas appliance (except for the Type B venting system as outlined 

in the installation instructions, if applicable) could create serious safety hazards may result in denial of certification 

by recognized national safety agencies and could be in violation of local building codes. This warranty does not 

cover any damages occurring from the use of my components not manufactured or supplied by DESA.

2.  The DESA appliance must be subjected to normal use. The decorative gas appliances are designed to burn either 

natural or propane/LP gas only. Burning conventional fireplace fuels such as wood, coal or any other solid fuel will 

cause damage to the decorative gas appliance, will produce excessive temperatures and will result in a fire hazard.

LIMITATION OF LIABILITy

It is expressly understood that DESA’s sole obligation and purchaser’s exclusive remedy under this warranty, expressed 

or implied, or in contract, tort or otherwise, shall be limited to replacement or repair as specified above. In no event shall 

DESA be responsible for any incidental or consequential damages caused by defects in its products, whether such dam-

age occurs or is discovered before or after replacement or repair and whether or not such damage is caused by DESA’s 

negligence. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above 

limitation or exclusion may not apply to you. The duration of any implied warranty with respect to this DESA decorative 

gas appliance is limited to the duration of the foregoing warranty.

INVESTIGATION OF CLAIMS AGAINST WARRANTy

DESA reserves the right to investigate any and all claims against this warranty and to decide upon method of settle-

ment. DESA is not responsible for work done without written consent. DESA shall in no event be responsible for any 

warranty work done without first obtaining DESA’s written consent.

HOW TO REGISTER A CLAIM

A (DESA) dealer or distributor should be contacted directly by the owner for any service, including service under 

these warranties. The repair and replacement of any defective part covered by these warranties is the responsibility 

of the nearest (DESA) dealer or distributor. 

OTHER

This warranty gives you specific rights and you may also have other rights which vary from state to state,. These 

warranties are given in lieu of any other expressed warranties. DESA does not authorize any person or representative 

to make representations to the contrary in connection with the sale of a decorative gas appliance.

55173

NOT A UPC

Summary of Contents for The Aspen GL36ST

Page 1: ...ght any appliance Do not touch any electrical switch Do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONS...

Page 2: ... to install and maintain your appliance it also con tains information that will enable you to obtain replace ment parts or optional accessory items when needed Keep it with your other important papers This appliance is only for use with the type of gas indi cated on the rating plate This appliance is not convertible for use with other gases TABLE OF CONTENTS Safety Information 3 Dimensions 4 Intro...

Page 3: ... for use with the type of gas indicated on the rating plate This ap pliance is not convertible for use with other gases 2 Forpropane LPfireplace donotplacepropane LP supply tank s inside any structure Locate propane LPsupplytank s outdoors Toprevent performance problems do not use propane LP fuel tank of less than 100 lbs capacity 3 If you smell gas shut off gas supply do not try to light any appl...

Page 4: ...ion chamber along with adequate accessibility clearance for servicing and proper operation Safety information Continued 16 Do not install fireplace directly on carpeting vinyl tile or any combustible material other than wood The fireplace must set on a metal or wood panel extending the full width and depth of the fireplace 17 Do not use fireplace if any part has been ex posed to or under water Imm...

Page 5: ...ing of anything other than the type of gas approved for use in this gas appliance This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electri cal Code ANSI NFPA 70 1987 and the CSA C22 1 Canadian Electrical Code for Canada The installation must conform with local codes or in the absence of local codes with th...

Page 6: ... observed 1 Do not connect this appliance to a chimney system used for a solid fuel burning fire place 2 Install in an area providing ventilation and adequate combustion air 3 Due to high temperatures do not locate this appliance in high traffic areas or near furniture and draperies 4 Never obstruct the front opening of the appli ance or the flow of combustion and ventilation air Keep control comp...

Page 7: ...tible Material Other Than Wood 52 3 4 1340 mm Min 46 11688 mm 22 3 4 578 mm vent pipe installation A6 B 1 type gas vent pipe is a double wall vent ing system not supplied which must be installed during rough framing of the appliance Any B 1 type gas vent system may be used for proper vent ing as long as the vent system is installed per the vent manufacturer s recommendations DESAsupplies this appl...

Page 8: ...e yond repair Wall Switch Installation 1 Remove the J box cover plate from side of appliance s outer surround 2 Using the 18 ga millivolt wire and wall switch both supplied connect wiring per wiring diagram see Figure 11 For more detail see Wiring Diagrams on page 16 Note If any of the original 10 feet supplied wire must be replaced use Thermostat Millivolt Wire 18 AWG Type CL2 105 C or equivalent...

Page 9: ...nformation sticker attached to the unit when field converting See Specifications page 15 when derating The gas control valve is secured to the burner pan assembly underneath the front ledge A 1 8 NPT plugged tapping is provided on the gas control valve for a test gauge connection immediately upstream of the gas supply connection to the ap pliance see Figures 13 and 14 Figure 12 Wiring Through Oute...

Page 10: ...e installation is completed Afterensuringthatthegasvalve is on apply a commercial leak detection solution to all con nections and joints If bubbles appear leaks can be detected and corrected Donotuseanopenflameforleak testing and do not operate any appliance if a leak is detected Typical Exterior Wall Gas Shutoff Installation Key Extension Shutoff Valve Fireplace Installation Continued Figure 15 T...

Page 11: ...Facing Material Figure 18 Correct Pilot Flame Pattern Millivolt Assembly Figure 19 Correct Pilot Flame Pattern Electronic Assembly Burner Flame Adjustment The air shutter located at the base of the main burner tube has been factory preset to the proper air to bas ratio which results in a long blue cleaner burning flame see Figure 20 If readjustment is necessary loosen the air shut ter screw and ro...

Page 12: ...T your left as you face the fireplace moves glass door s top inner corner UP moving spring clip to the RIGHT moves glass door s top inner corner DOWN c When door alignment is satisfactory use Phillips screwdriver to retighten spring clip screw WARNING When fireplace is in operation both sets of cabinetdoorsoneachsideofthe fireplace must be either FULLY OPEN or FULLY CLOSED If not a fire hazard may...

Page 13: ... burning logs will give off a paper burning smell Orange flame will also be pres ent Open window to vent smell This will only last a few hours 1 STOP Read the safety information column 1 2 Turn wall switch to the OFF position 3 Turn off all electric power to the appliance 4 Open control access panel 5 Push in gas control knob and turn clock wise to the OFF position see Figure 23 Note It is recomme...

Page 14: ...turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service tech nician or gas supplier Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control syst...

Page 15: ...s clean by vacuuming or brushing at least twice a year Take care not to alter the set tings on the pilot assembly Do not use abrasive liquids or cleaners for cleaning glass doors and trims Any household glass cleaner should suffice Do not clean doors when hot Allow appliance to cool before cleaning Technical Service You may have further questions about installation operation or troubleshooting If ...

Page 16: ...UPPLY millivolt wiring diagram STEP DOWN TRANSFORMER EV2 SUPPLY INCOMING MAIN GAS EV1 TO GAS LINE BURNER 24V AC N C SW HEAT LIMIT SWITCH 120V AC 120V AC INCOMING OR BREAKER FUSE BOX OFF ON SUPPLIED WALL SWITCH GREEN BLACK WHITE 120v 60Hz 0 7A ELECTRICAL RATING BLACK WHITE GREEN OPTIONAL REMOTE CONTROL SENSOR PILOT IGNITOR PV GND PV MV TR MV TH IGN Electronic wiring diagram Wiring Diagrams ...

Page 17: ...ective control valve 1 Wall switch wires defective 2 Thermopile or sensor not generating sufficient voltage 1 Pilot flame may be too low causing safety pilot to drop out 1 Millivolt output on thermo pile too high REMEDY 1 Check to see if you have gas supply 2 Hold regulator control valve in the PILOT position for 2 to 3 minutes to purge air If you smell gas stop and wait for a few minutes before t...

Page 18: ...current is being sent back to regulator 2 If valve knob and wall switch are in the ON position prob able defective control valve 1 Wall switch wires defective 2 Thermocouple generator or sensor not generating suf ficient voltage 1 Pilot flame may be too low causing safety pilot to drop out 1 Output on flame sensor too high REMEDY 1 Check to see if you have gas supply 2 Remove debris and dirt in sp...

Page 19: ...ll Switch Kit 22180 Wall Switch 14112 Cover Plate 14113 For use with all models Ignition Control 110286 01 For use with all models Gas Valve Conversion Kit Millivolt Propane LP Gas PC GL36 Millivolt Natural Gas NC GL36 Electronic Propane LP Gas PC GL36E Electronic Natural Gas NC GL36E Brushed Brass Cabinet Style Door Kit DBBGL36ST Right Panel Assy 22367 Left Panel Assy 22368 For use with all model...

Page 20: ...fications 1 The gas appliance must be installed as per the DESA installation instructions and local building codes The use of components manufactured by others with this DESAgas appliance except for theType B venting system as outlined in the installation instructions if applicable could create serious safety hazards may result in denial of certification by recognized national safety agencies and ...