background image

9

101283

SYMPTOM

Pilot fails
to light.

Pilot lights
but goes
out when
automatic
control valve
button
is released.

Maximum
burn rate
is low.

Soot forming
inside heater,
flame 100%
yellow.

POSSIBLE CAUSE

1. Propane supply valve closed

on propane tank(s).

2. Excess-flow check valve

closed.

3. Air in gas line.

4. Blockage in pilot orifice.
5. Piezo ignition system not

sparking.

1. Not enough warm-up time.

2. Low gas pressure.

3. Thermocouple loose or

needs to be replaced.

4. Automatic control valve

needs to be replaced.

1. Main burner valve not fully

open.

2. Plugged gas orifices.
3. Low gas pressure.

4. Low fuel supply.

1. Main burner valve not open

enough.

2. Low fuel supply.

REMEDY

1. Open propane supply valve

slowly.

2. Close propane supply valve on

propane tank and reopen
slowly.

3. Allow several minutes to purge

air with automatic control
valve button depressed.

4. Replace pilot orifice.
5. Adjust ignitor electrode gap to

.120". Check wire lead for
damage. Replace piezo ignitor
and/or ignitor electrode as
necessary.

1. Relight, hold automatic control

valve button in 45 seconds.

2. Check propane tank(s) for

proper gas supply.

3. Tighten connection or replace

thermocouple.

4. Replace automatic control

valve.

1. Fully open main burner valve

by turning the valve handle
towards ON position until it
stops.

2. Replace gas orifice.
3. Check gas supply; check

regulator output.

4. Consult propane gas supplier.

1. Adjust main burner valve

slowly towards ON position
until flame has more blue
color.

2. Consult propane gas supplier.

TROUBLE-

SHOOTING

You may have further ques-
tions about this heater. If so,
contact DESA International’s
Technical Service Department
at 1-800-323-5190.

WARNING ICON

G 001

 WARNING

Never attempt to service heater while it is connected to
propane supply, operating, or hot. Severe burns can occur.

Summary of Contents for RCP2000

Page 1: ...01 GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PRO VIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE...

Page 2: ...WARNING NOT FOR HOME OR RECREATIONAL VEHICLE USE The heater is designed for use as a construction heater The primary purpose of construction heaters is to provide temporary heating of buildings under...

Page 3: ...heater Keep heater away from strong drafts water spray rain or dripping water Never attach duct work to heater Neverblockairinlet bottomofshell orairoutlet aroundtopofshell ofheater Keep children and...

Page 4: ...g items applied to heater for shipment Keep plastic cover caps attached to inlet connector and hose regulator assembly for storage 2 Remove all items from carton 3 Check all items for shipping damage...

Page 5: ...or one larger tank may be needed in colder weather Your local propane gas dealer will help you select the proper supply system Average Temperature F At Tank Location 60 40 32 20 10 0 Number Of Tanks...

Page 6: ...nt down protects regulator from weather damage Supply Valve POL Fitting Hose Regulator Vent pointing down 3 Connect hose to the inlet connector Tighten firmly using 9 16 wrench IMPORTANT Use extra hos...

Page 7: ...installation ventilation and safety information 2 Locate heater on stable and level surface Make sure strong drafts do not blow on heater WARNING ICON G 001 WARNING Fully close main burner valve befor...

Page 8: ...towards the OFF position until it stops Note Arrows on main burner valve handle show direction for ON and OFF To Restart Heater 1 Wait five minutes after stopping heater 2 Restart heater by following...

Page 9: ...rge air with automatic control valve button depressed 4 Replace pilot orifice 5 Adjust ignitor electrode gap to 120 Check wire lead for damage Replace piezo ignitor and or ignitor electrode as necessa...

Page 10: ...ly original replacement part s either contact your nearest Parts Central or call DESA International s Technical Service Department at 1 800 323 5190 When calling DESA International have ready your nam...

Page 11: ...Piezo Ignitor 1 18 098838 01 Sheet Metal Nut 1 19 LPA4010 Debris Shield 1 20 097155 01 Safety Control Valve 1 21 097157 01 Female Connector 1 22 098828 01 Female Compression Elbow 1 23 098835 01 Nut...

Page 12: ...LUDING WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR POSE DESA International assumes no responsibility for indirect incidental or consequential damages Some states do not allow the ex...

Reviews: