9
101697
7. Display alternates between “th” and the temperature selected. Heater has
accepted the new thermostat setting. Press
button to activate the new
thermostat setting and start heater operation with thermostat.
NOTE:
This thermostat has a 6˚F differential.
Example:
With thermostat set at
72˚F, the heater will cycle ON if the ambient temperature drops to 69˚F. The
heater will cycle OFF when the ambient temperature rises to 75˚F.
To Change Thermostat Setting During Operation
1. Press
button until display flashes. The heater will stop and the display will
flash the current thermostat setting.
2. Press and hold
button to increase thermostat setting or
button to decrease
thermostat setting. Display will automatically advance to next screen 4 seconds
after the last adjustment.
3. Display alternates between “th” and the temperature selected . Heater has
accepted the new thermostat setting. Press
button to activate the new
thermostat setting and start heater operation with thermostat.
To Stop Heater
Press
(OFF) button.
Figure 9 -
Alternating Between “th” and the Temperature Selected
To Restart Heater
Repeat steps under Operation With Thermostat, page 8 to operate heater with
thermostat. Refer to step under Operation Without Thermostat, page 7 to operate
heater without thermostat.
Figure 10 - OFF Button Location
OFF Button