background image

6

105986

VENT-FREE PROPANE/LP GAS STOVE HEATER

SUN VALLEY STOVE COMPANY

For more information, visit www.desatech.com

AIR FOR
COMBUSTION AND
VENTILATION

Continued

Figure 3 - Ventilation Air from Outdoors

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation
grills or ducts. You must provide two per-
manent openings: one within 12" of the
ceiling and one within 12" of the floor.
Connect these items directly to the outdoors
or spaces open to the outdoors. These spaces
include attics and crawl spaces. Follow the
National Fuel Gas Code, NFPA 54/ANS
Z223.1, Section 5.3, Air for Combustion and
Ventilation
 for required size of ventilation
grills or ducts.

IMPORTANT:

 Do not provide openings

for inlet or outlet air into attic if attic has
a thermostat-controlled power vent.
Heated air entering the attic will activate
the power vent.

Figure 2 - Ventilation Air from Inside Building

VENTILATION AIR

Ventilation Air From Inside
Building

This fresh air would come from an adjoining
unconfined space. When ventilating to an
adjoining unconfined space, you must pro-
vide two permanent openings: one within
12" of the ceiling and one within 12" of the
floor on the wall connecting the two spaces
(see options 1 and 2, Figure 2). You can also
remove door into adjoining room (see op-
tion 3, Figure 2). Follow the National Fuel
Gas Code, NFPA 54/ANS Z223.1, Section
5.3, Air for Combustion and Ventilation
 for
required size of ventilation grills or ducts.

Outlet
Air

Ventilated
Attic 

Outlet
Air

Inlet
Air

Inlet Air

Ventilated 

Crawl Space

To 

Crawl

Space

To Attic

Or

Remove

Door into

Adjoining

Room,
Option

3

Ventilation Grills 

Into Adjoining Room,

Option 2

Ventilation

Grills 

Into Adjoining 

Room,

Option 1

12"

12"

 WARNING: Rework work-

sheet, adding the space of the
adjoining unconfined space. The
combined spaces must have
enough fresh air to supply all
appliances in both spaces.

Summary of Contents for MSVFBP

Page 1: ...WARNING The MSVFBP R series vent free gaslogheaterisonlyapprovedforuseinthe Sun Valley MC series and MCH P series cast iron stove models Indicates Color Suffix Designation Save this manual for future...

Page 2: ...heater Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable material on or near the appliance Never pl...

Page 3: ...oss out a vent or up a chimney Heat is generated by realistic dancingyellowflames Thisheater is designed for vent free operation State and local codes in some areas prohibit the use of vent free heate...

Page 4: ...ater vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking o...

Page 5: ...________Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual...

Page 6: ...power vent Figure 2 Ventilation Air from Inside Building VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining un...

Page 7: ...e is a freestanding unit designed to set directly on the floor Do not place stove directly on carpeting vinyl tile or any com bustiblematerialotherthanwood Thestove mustsetonametalorwoodpanelextending...

Page 8: ...ee Figure 5 Use an adjustable wrench or a 10 mm socket Remove six 6 bolts and washers Keep bolts and washers to reattach back panel later 5 Remove all contents from inside stove cavity Contents includ...

Page 9: ...stepbolt Tightenstepboltuntilsnug Make sure door moves freely 11 Install door catch bolt M8 x 1 25 55mm with two M8 hex nuts into threaded hole on stove body see Fig ure 8 page 8 Use an adjustable wre...

Page 10: ...center of heater base Log will fit securely on base IMPORTANT Make sure log does not cover any burner ports and does not touch the stove cavity see Figure 16 9 Fasten back panel to stove with six 6 M...

Page 11: ...uhave the items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection sediment trap tee joint pipe wrench An CSA AGA design certified...

Page 12: ...off valve from gas supply piping system Pressures in ex cess of 1 2 psig will damage heater regulator 2 Cap off open end of gas pipe where equipment shutoff valve was con nected 3 Pressurize supply pi...

Page 13: ...circulation Avoid heat sources such as lamps direct sun light fireplace or heat and air condi tioning ducts WARNING Do not connect this thermostat to a power source Electrical shock and or fire hazard...

Page 14: ...or If you smell gas STOP Follow B in the safety in formation column 1 If you don t smell gas go to the next step 6 Press in and turn control knob coun terclockwise to the PILOT position Press in contr...

Page 15: ...operation follow in structionsuppliedwiththermostatacces sory GWMT1 For wall switch operation follow instructions supplied with GWMS2 Figure 28 Setting the Remote Selector Switch Control Knob and Fla...

Page 16: ...to vent smell This will only last a few hours LIGHTING INSTRUCTIONS MSVFBP VARIABLE MANUAL CONTROL MODELS Figure 30 Control Knob and Ignitor Button Location Control Knob Ignitor Button Figure 31 Pilot...

Page 17: ...ure 34 Correct Pilot Flame Pattern Figure 35 Incorrect Pilot Flame Pattern BURNER PRIMARY AIR HOLES Air is drawn into the burner through the holes in the fitting at the burner entrance These holes may...

Page 18: ...ilot assembly clean and free of dustanddirt Tocleanthesepartswerecom mend using compressed air no greater than 30 PSI Your local computer store hard ware store or home center may carry com pressed air...

Page 19: ...REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace piezo ignitor 6 Replace piezo i...

Page 20: ...pro pane LP gas company 3 Observe minimum installation clear ances see page 7 4 Clean burner see Cleaning and Mainte nance page 18 or replace burner orifice 1 Properly locate logs see Installing Gas L...

Page 21: ...cking noise just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMED...

Page 22: ...ur heater the replacement part number SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition heater will not produce specified heat When Gas Quality Is B...

Page 23: ...an turn the gas log heater on and off without ever leaving the comfort of your easy chair RECEIVER AND HAND HELD REMOTE CONTROL KIT GHRC SERIES For remote ready models Allows the gas log heater to be...

Page 24: ...OVE HEATER SUN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN MSVFBPR O F F P I L O T O N H I L O H I L O O F F P I L O T O N 17 17 18 19 22 15 14 16 13 1...

Page 25: ...1 7 099056 19 Burner Orifice Injector 1 8 102980 01 Burner 1 9 099387 13 Pilot Tube 1 10 103781 02 Gas Control Valve 1 11 103345 02 Lower Bracket 1 12 M11084 38 Screw 8 x 38 7 13 104383 02CK Painted...

Page 26: ...T FREE PROPANE LP GAS STOVE HEATER SUN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN MSVFBP 20 7 20 20 5 8 15 16 18 22 20 21 17 19 18 3 9 12 1 10 11 6 20...

Page 27: ...or 1 8 102798 01 Inlet Tube 1 9 102779 04 Outlet Burner Tube 1 10 099056 19 Burner Orifice Injector 1 11 102843 01 Burner Clip 1 12 102980 01 Burner 1 13 102568 08 Control Valve 1 14 098508 01 Valve R...

Page 28: ...E LP GAS STOVE HEATER SUN VALLEY STOVE COMPANY For more information visit www desatech com 1R 1C 1L 5 8 8 7 4 6 5 5 7 1 7 2 5 4 7 3 2 3 ILLUSTRATED PARTS BREAKDOWN SUN VALLEY STOVE MC SERIES Indicates...

Page 29: ...lain Enamel Almond 4 Total Per Stove 1 104175 14 One Leg Porcelain Enamel Green 4 Total Per Stove 1 104175 15 One Leg Porcelain Enamel Red 4 Total Per Stove 1 6 104176 01 Leg Leveler bolt M8 x 1 25 55...

Page 30: ...LP GAS STOVE HEATER SUN VALLEY STOVE COMPANY For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN SUN VALLEY STOVE MCH P SERIES HEPPLEWHITE STOVE DESIGN 2 9 11 5 4 10 8 6 13 14 12 1...

Page 31: ...ft Rear Leg Metallic Black 1 104175 31 Left Rear Leg Porcelain Enamel Black 1 104175 32 Left Rear Leg Porcelain Enamel Navy 1 104175 33 Left Rear Leg Porcelain Enamel Almond 1 104175 34 Left Rear Leg...

Page 32: ...ctive heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXP...

Reviews: