KEEP THIS WARRANTY

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our
standard written warranty. We make no other warranty, expressed or implied.

WARRANTY INFORMATION

LIMITED WARRANTY

MEDALLION VENT-FREE HEATERS

Cans Unlimited, Incorporated warrants this product to be free from defects in materials and components for two
(2) years from the date of first purchase, provided that the product has been properly installed, operated and
maintained in accordance with all applicable instructions. To make a claim under this warranty the Bill of Sale or
cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers only the cost of part(s) required
to restore this heater to proper operating condition and an allowance for labor when provided by a Cans Unlimited,
Incorporated Authorized Service Center. Warranty part(s) MUST be obtained through authorized dealers of this
product and/or Cans Unlimited, Incorporated who will provide original factory replacement parts. Failure to use
original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in
accordance with all local codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts
that fail or become damaged as a result of misuse, accidents, lack of proper maintenance or defects caused by
improper installation. Travel, diagnostic cost, labor, transportation and any and all such other costs related to
repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE
OF THE PRODUCT; THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED
WARRANTIES AND LIMITS THE DURATION OF ANY AND ALL IMPLIED WARRANTIES, INCLUD-
ING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO TWO
(2) YEARS ON ALL COMPONENTS  FROM THE DATE OF FIRST PURCHASE: AND CANS UNLIMITED,
INCORPORATED’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT
AND CANS UNLIMITED, INCORPORATED SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES
WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of
incidental or consequential damages, so the above limitation on implied warranties, or exclusion or limitation on
damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

105935-01
REV. B
03/00

105935 01

NOT A UPC

Distributed by: C.U.I.
Cans Unlimited, Incorporated
1700 Poplar Drive
Greer

SC 29651

GAS PRODUCTS

Summary of Contents for Medallion MR10NT

Page 1: ...qualified installer service agency or the gas supplier WARNING Improper instal lation adjustment alteration service or maintenance can causeinjuryorpropertydam age Refer to this manual for correct in...

Page 2: ...urns fire explosion and car bon monoxide poisoning DANGER Carbon monoxide poisoning may lead to death 5 This heater needs fresh outside air ven tilation to run properly This heater has an Oxygen Deple...

Page 3: ...er for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletio...

Page 4: ...lume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggre gate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not les...

Page 5: ...al ______________Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with t...

Page 6: ...of the adjoiningunconfinedspace The combined spaces must have enough fresh air to supply all appliances in both spaces Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills...

Page 7: ...fromfloor ceiling andjoin ing wall CAUTION If you install the heater in a home garage heaterpilotandburnermustbe at least 18 inches above floor locate heater where moving vehicle will not hit it IMPOR...

Page 8: ...l Stud Method For attaching mounting screw to wall stud 1 Drill hole at marked location using 9 64 drill bit 2 Insert mounting screw into wall stud 3 Tighten screw until 1 16 space thick ness of penny...

Page 9: ...wn in Figure 12 Locate sediment trap where it is within reach for cleaning Locate sedi ment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps...

Page 10: ...onnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 13 2 Pressurize supply piping system by ei ther using compressed air or op...

Page 11: ...rops below the set temperature Selecting a higher setting will cause the heater to run longer producing greater heat output At lower settings the heater will run less Note The thermostat sensing bulb...

Page 12: ...INTENANCE ODS PILOT AND BURNER ORIFICE Use a vacuum cleaner pressurized air or small soft bristled brush to clean CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit ev ery 2 500...

Page 13: ...base panel 4 Replace ignitor cable 5 Replace ignitor 6 Replace piezo ignitor 7 Replace ignitor 1 Turn on gas supply or open equipment shutoff valve 2 Turn control knob to PILOT position 3 Press in con...

Page 14: ...s see Cleaning and Maintenance page 12 or replace burner orifice s 2 Contact local natural gas company 3 Replace burner 4 Replace gas regulator 1 Plaque damaged 2 Inlet gas pressure is too low 3 Contr...

Page 15: ...nections page 10 1 Open window and or door for ventilation 2 Contact local natural gas company 3 Clean ODS pilot see Cleaning and Maintenance page 12 1 Locate and correct all leaks see Checking Gas Co...

Page 16: ...16 105935 VENT FREE NATURAL GAS HEATER MR10NT 12 A B 16 7 8 4 6 5 3 2 1 11 14 13 19 18 6 17 15 16 10 9 7 1 ODS PILOT 7 2 ILLUSTRATED PARTS LIST MR10NT...

Page 17: ...823 37 Screw Hex 8 x 1 4 10 7 503329 ODS Pilot Assembly 1 7 1 098514 01 Thermocouple 1 7 2 098594 01 Ignitor Electrode 1 8 099884 03 Burner Assembly 1 9 099056 24 Injector 1 10 104087 01 Tubing Burner...

Page 18: ...s call Cans Unlimited Incorporated s Technical Ser vice Department at 1 800 922 7407 for in formation When contacting your dealer or Cans Un limited Incorporated have ready your name your address mod...

Page 19: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 20: ...he unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper mai...

Reviews: