background image

www.desatech.com

111604-01E

5

LOCAL CODES

Install and use fireplace with care. Follow all lo-
cal codes. In the absence of local codes, use the
latest edition of The National Fuel Gas Code ANSI
Z223.1/NFPA 54
*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY  10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA  02269

Note:

 Where listed vented decorative logs are re-

quired, thermostat operation is not permitted.

UNPACKING

 CAUTION: Do not remove

the data plates attached to the
heater base assembly. The data
plates contain important war-
ranty and safety information.

1.

With utility knife, cut the carton all the way
around above the staples on the bottom tray.
Lift the carton off the heater. Remove pack-
ing. 

Note:

 The hood is located in the packing

on the right hand side of the heater front. Lift
the heater off the bottom tray.

2.

Locate two screws above top corners of the
fireplace screen. Remove and discard these
screws. Lift fireplace screen up and pull out
to remove.

3.

Remove protective packaging applied to logs,
log base assembly, and fireplace.

4.

Remove fireplace hood from carton insert.

5.

Check all items for any shipping damage. If
damaged, promptly inform dealer where you
bought fireplace.

PRODUCT FEATURES

OPERATION

This vent-free fireplace is clean burning. It requires
no outside venting. There is no heat loss out a vent
or up a chimney. Heat is generated by both realis-
tic flames. When used without the blower, the fire-
place requires no electricity making it ideal for
emergency backup heat. This heater is designed
for vent-free operation. It has been tested and ap-
proved to ANSI Z21.11.2 standard for unvented
heaters. State and local codes in some areas pro-
hibit the use of vent-free heaters.

SAFETY DEVICE

This fireplace has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot is a required feature for vent-free room
heaters. The ODS/pilot system shuts off the fire-
place if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This fireplace has a piezo ignitor. This system re-
quires no matches, batteries, or other sources to
light fireplace.

OPTIONAL BLOWER ASSEMBLY
(GA3700 SERIES & GA3700TA
SERIES)

This fireplace accepts an optional blower assem-
bly (not included). The GA3700TA Series blower
operates thermostatically and features a variable
speed control. The GA3700 Series blower oper-
ates manually and also features a variable speed
control. The blower circulates heated air from the
fireplace into the room. See Accessories, page 29.

AIR FOR COMBUSTION

AND VENTILATION

 WARNING: This heater shall

not be installed in a confined space
or unusually tight construction
unless provisions are provided
for adequate combustion and ven-
tilation air. Read the following in-
structions to insure proper fresh
air for this and other fuel-burning
appliances in your home.

Today’s homes are built more energy efficient than
ever. New materials, increased insulation, and new
construction methods help reduce heat loss in
homes. Home owners weather strip and caulk
around windows and doors to keep the cold air out
and the warm air in. During heating months, home
owners want their homes as airtight as possible.

While it is good to make your home energy effi-
cient, your home needs to breathe. Fresh air must
enter your home. All fuel-burning appliances need
fresh air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel
burning appliances draw air from the house to
operate. You must provide adequate fresh air for
these appliances. This will insure proper venting
of vented fuel-burning appliances.

Summary of Contents for LMFP33NR

Page 1: ...o not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructi...

Page 2: ...ance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating pla...

Page 3: ...p this manual for reference It is your guide to safe and proper operation of this heater WARNING Any change to this heater or its controls can be dangerous WARNING Do not use a blower insert heat exch...

Page 4: ...This fireplace needs fresh air ventilation to run properly This fireplace has an Oxygen Deple tion Sensing ODS safety shutoff system The ODS shuts down the fireplace if enough fresh air is not availab...

Page 5: ...odes in some areas pro hibit the use of vent free heaters SAFETY DEVICE This fireplace has a pilot with an Oxygen Deple tion Sensing ODS safety shutoff system The ODS pilot is a required feature for v...

Page 6: ...g of all appliances installed in that space and an unconfined space as a space whose vol ume is not less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all ap...

Page 7: ...Section 5 3 or applicable local codes 40 000 33 000 73 000 AIR FOR COMBUSTION AND VENTILATION Continued Figure 4 Ventilation Air from Outdoors Figure 3 Ventilation Air from Inside Building Outlet Air...

Page 8: ...top of your fireplace except where standoff spacers are integrally attached If standoff spacers are attached to your fireplace these spacers can be placed directly against wall or framing materials U...

Page 9: ...anging screws 10 x 6 25 shoul der into holes in cabinets Place the assembled trimontofireplacecabinet Alignhangingnotches on trim with hanging screws on side of fireplace see Figure 7 Push trim firmly...

Page 10: ...ocate access hole so cabinet mantel will cover it when installed Note You can secure base to floor using wood screws Countersinkscrewheadsandputtyover 5 Route flexible gas line through access hole in...

Page 11: ...gh opening If installing in a corner use dimensions shown in Figure 14 for the rough opening The height is 33 which is the same as the wall opening above 2 If using blower install duplex outlet to the...

Page 12: ...er the equip ment shutoff valve The flexible gas line must be the last item installed on the gas piping See Installing Gas Piping to Fireplace Loca tion pages 13 and 14 9 Carefully set fireplace in fr...

Page 13: ...ulator WARNING A qualified ser vice person must connect fire place to gas supply Follow all local codes CAUTION Neverconnectpro pane LP fireplace directly to the propane LPsupply Thisfireplace require...

Page 14: ...valve to fireplaces ApplypipejointsealantlightlytomaleNPTthreads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged fireplace valves Never use sealan...

Page 15: ...through one of the access holes NOTICE Most building codes do not permit concealed gas con nections A flexible gas line is provided to allow accessibility fromthefireplace seeFigure22 The flexible gas...

Page 16: ...r gas meter for natural gas or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 5 Correct all leaks...

Page 17: ...accordance with these diagrams or failure to use only parts specifically approved withthisheatermayresultinprop erty damage or personal injury WARNING After installation and periodically thereafter ch...

Page 18: ...RECEIVER AND HAND HELD REMOTE CONTROL Four AA batteries and threeAAA batteries are re quired to operate this heater with the wireless hand held remote control set Four AA batteries must be installed i...

Page 19: ...nce and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING If fireplace has glass doors never operate this heater with glass doors c...

Page 20: ...son or gas supplier for repairs Note If pilot goes out repeat steps 4 through 8 9 Slightly push in and turn control knob coun terclockwise to the ON position OPERATING HEATER Continued AUTO MAN Contro...

Page 21: ...is set press the up or down key to start the timer When the desired time has elapsed the appli ance will automatically switch off Child Safety Lock Out To lock the remote control keys press the On Off...

Page 22: ...st or lint Periodically in spect these holes for any blockage and clean if needed Blocked air holes will create soot MAIN BURNER Periodically inspect all burner flame holes with the fireplace running...

Page 23: ...ressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool...

Page 24: ...pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo igni...

Page 25: ...ed burner 3 Gas regulator defective 1 Not enough air 2 Gas regulator defective 3 Residues from manufacturing processes and logs curing REMEDY 1 Press in control knob fully 2 AfterODS pilotlights keepc...

Page 26: ...Operate burners until air is re moved from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see pages 9 through 13 4 Clean burners see C...

Page 27: ...ile heater is running 2 Refill supply tank propane LP only 3 Locate and correct all leaks see Checking Gas Connec tions page 16 1 Open window and or door for ventilation 2 Contact local natural or pro...

Page 28: ...ill not produce specified heat for propane LP unit propane LP gas supply may be low You may feel your gas pressure is too low If so contact your local gas supplier REPLACEMENT PARTS Note Use only orig...

Page 29: ...maximize heat distribution FIREBOX BRICK LINER G8000A Series Not Shown For all models Ceramic fiber firebox liner adds the look of real brick INFORMATION VIDEO 108917 01 For all models A care and mai...

Page 30: ...www desatech com 111604 01E 30 ILLUSTRATED PARTS BREAKDOWN MODELS LMFP33PR AND LMFP33NR SHOWN 17 26 4 8 12 25 20 21 7 6 4 3 2 1c 1b 1a 5 1d 1e 9 27 14 13 15 16 22 11 10 19 23 18 24 28...

Page 31: ...1 Burner 2 9 M11084 38 M11084 38 Screw 8 16 x 38 4 10 104236 01CK 104236 01CK Painted Base Assy 1 11 M12461 26 M12461 26 Screw 10 32 x 38 4 12 Firebox Bottom 1 13 M50104 02 M50104 02 Bushing 1 14 0982...

Page 32: ...www desatech com 111604 01E 32 ILLUSTRATED PARTS BREAKDOWN FIREBOX LMFP33PR AND LMFP33NR 4 11 14 8 14 9 3 14 9 9 2 1 6 7 10 14 12 5 14 13 16 15...

Page 33: ...ht Front Side 1 4 Left Front Side 1 5 098304 01 Phillips Pan Head Screw 10 16 x 38 9 6 104239 01CK Top Front Louver 1 7 101712 03 Firebox Hood 1 8 Firebox Support 2 9 099230 02 Shoulder Screw 4 10 Fir...

Page 34: ...____________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________...

Page 35: ...____________________________________________________ ___________________________________________________________ ___________________________________________________________ ___________________________...

Page 36: ...inal factory replacement parts voids this warranty The heater MUST be installed by a qualified in staller in accordance with all local codes and instructions furnished with the unit This warranty does...

Reviews: