Desa LGCFTN Owner'S Operation And Installation Manual Download Page 27

www.desatech.com

119508-01B

27

SPECIFICATIONS

REPLACEMENT PARTS

LGCFTP

•  Rating (Variable): 14,000/26,000 Btu/Hr
•  Gas Type: Propane/LP Only
•  Ignition: Piezo
•  Pressure Regulator Setting: 8" W.C.
•  Inlet Gas Pressure (in. of water)*:
  Maximum 14" W.C., Minimum 11" W.C.
•  Dimensions (H x W x D)

  Fireplace - 25 

7

/

8

" x 26 

13

/

16

" x 9 

3

/

8

"

  Carton - 32 

5

/

8

" x 27 

3

/

16

" x 11 

5

/

8

"

LGCFTN

•  Rating (Variable): 14,000/26,000 Btu/Hr
•  Gas Type: Natural Only
•  Ignition: Piezo
•  Pressure Regulator Setting: 3" W.C.
•  Inlet Gas Pressure (in. of water)*:
  Maximum 10.5" W.C., Minimum 5" W.C.
•  Dimensions (H x W x D)

  Fireplace - 25 

7

/

8

" x 26 

13

/

16

" x 9 

3

/

8

"

  Carton - 32 

5

/

8

" x 27 

3

/

16

" x 11 

5

/

8

"

Note:  Use  only  original  replacement  parts. 
This will protect your warranty coverage for 
parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If 
they can’t supply original replacement part(s), 
call DESA Heating, LLC at 1-866-672-6040.
When  calling  DESA  Heating,  LLC,  have 

ready:

•  your name
•  your address
•  model and serial numbers of your heater
•  how heater was malfunctioning
•  purchase date
Usually, we will ask you to return the part to 

the factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. 

If  they  can’t  supply  original  replacement 

part(s),  either  contact  your  nearest 

Parts 

Central

 (see page 31) or call DESA Heating, 

LLC at 1-866-672-6040 for referral informa-

tion. A list of authorized dealers can be found 

by visiting 

www.desatech.com.

When  calling  DESA  Heating,  LLC,  have 

ready:

•  model and serial numbers of your heater
•  the replacement part number

SERVICE hINTS

When Gas Pressure Is Too Low

•  pilot will not stay lit
•  burner will have delayed ignition
•  fireplace will not produce specified heat

•  propane/LP gas supply may be low (pro

-

pane/LP only)

You may feel your gas pressure is too low. If 
so, contact your local propane/LP or natural 

gas supplier.

TEChNICAL SERVICE

You may have further questions about installa

-

tion, operation, or troubleshooting. If so, con

-

tact DESA Heating, LLC at 1-866-672-6040. 

When  calling  please  have  your  model  and 
serial numbers of your heater ready.

You can also visit DESA Heating, LLC’s web 

site at 

www.desatech.com

.

* For purposes of input adjustment

Summary of Contents for LGCFTN

Page 1: ...ectrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire dep...

Page 2: ...pe of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer WARNING This product c...

Page 3: ...se with this fire place Due to high temperatures the appliance should be located out oftrafficandawayfromfurniture and draperies SAFETY Continued Do not place clothing or other flammable material on o...

Page 4: ...oke less If logs ever appear to smoke turn off fireplace and call a qualified service person Note During initial operation slight smoking could occur due to log cur ing and fireplace burning manufactu...

Page 5: ...e assembly The data plates contain important warranty and safety information 1 Remove fireplace from carton 2 Remove all protective packaging applied to fireplace for shipment 3 Make sure your firepla...

Page 6: ...Figure 4 Assembling Trim Top Trim Mitered Edge Side Trim Slot Shim Adjusting Plate Set Screws Slot Figure 5 Attaching Trim to Compact Fireplace Assembled Trim Shoulder Screw Figure 2 Assembling Firep...

Page 7: ...ilation Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of un usually tight construction you m...

Page 8: ...__ Btu Hr maximum the space can support ________ Btu Hr actual amount used Air For Combustion and Ventilation Continued Example 51 200 Btu Hr maximum the space can support 56 000 Btu Hr actual amount...

Page 9: ...NOTICE Thisheater isintended for use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your pri mary heat source If you have a centralheatingsys...

Page 10: ...RTANT Only use optional cabinet or corner mantels speci fied in this manual Purchase the optional mantel from your dealer see Accessories page 30 WARNING Never install the fireplace in a bedroom or a...

Page 11: ...ies page 30 Brass trim will extend past sides of fireplace ap proximately 1 2 This will cover the rough edges of the wall opening If installing a built in mantel above the fireplace you must follow th...

Page 12: ...leaks See Checking Gas Connections page 17 10 If using optional brass trim kit install the trim after final finishing and or painting of wall See instructions included with brass trim accessory for a...

Page 13: ...shield off of the shoulder screw see Fig ure 15 Note If you do not have a short Phil lips screwdriver the screen log set and branch support must be removed so a longer screwdriver may be used See Con...

Page 14: ...through the hole in left side of baffle Pull wire harness through lower opening above where valve shield was removed see Figure 16 7 Insert the 4 wire harness into one of the round holes in rear of v...

Page 15: ...rd and tie it up with the plastic wire strap see Figure 19 Set the cable bundle between the burner bracket and outer casing away from the burner 6 Reinstall valve cover shield Figure 18 Wiring Diagram...

Page 16: ...Figure 21 IMPORTANT Install an equipment shutoff valve in an access ble location The equip ment shutoff valve is for turning on and shut ting off the gas to the appliance Check your building codes fo...

Page 17: ...o gas piping and or fittings 4 Apply pipe joint sealant lightly to male threads of gas connector attached to flexible gas line equipment shutoff valve see Figure 23 5 Check all gas connections for lea...

Page 18: ...ly piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints fro...

Page 19: ...l repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure page 20 Ignitor Button Figure 27 Control Knob In the OFF Position Control Knob FOR YOUR SAFETY READ BE...

Page 20: ...OL OPERATION The thermostatic control used on this fireplace differs from standard thermostats Standard thermostats simply turn on and off the burner The thermostat used on this fireplace senses the r...

Page 21: ...orange for approximately one hour until the log cures If burner flame pattern is incorrect as shown in Figure 32 turn fireplace off see To Turn Off Gas to Appliance page 20 see Troubleshooting page 23...

Page 22: ...ntrol areas burner and cir culating air passageways of fireplace clean Inspect these areas of fireplace before each use Have fireplace inspected yearly by a qualified service person Fireplace may need...

Page 23: ...in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Free ignitor cable if pinched by any...

Page 24: ...low 2 Burner orifice is clogged 1 Burner orifice is clogged or damaged 2 Burner damaged 3 Low inlet gas pressure 4 Gas regulator defective REMEDY 1 Press in control knob fully 2 After ODS pilot light...

Page 25: ...When heated vapors from furniture polish wax carpet cleaners etc may turn into white powder residue 1 Metal expanding while heat ing or contracting while cooling REMEDY 1 Check burner for dirt and de...

Page 26: ...d 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Not enough combustion ve...

Page 27: ...of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory Parts Not Under Warranty Contact authorized dealers of this product If they can t s...

Page 28: ...tech com 119508 01B 28 Parts Models LGCFTP AND LGCFTN 23 29 32 8 14 36 38 37 13 7 8 17 33 11 4 10 4 7 8 30 3 1 2 9 19 6 22 31 21 40 16 15 18 24 28 5 41 34 25 20 4 35 12 24 12 1 25 14 8 3 42 27 26 39 3...

Page 29: ...649 02 Branch Support 1 21 099415 09 Gas Regulator 1 099415 10 Gas Regulator 1 22 102875 01 Regulator Bracket 1 23 101381 01 Valve Cover and Piezo 1 24 099387 11 Pilot Tube 1 25 098271 06 Ignitor Cabl...

Page 30: ...corner design features clean classic lines Available in a stained oak 2 tone finish or an unfinished hardwood ready to stain or paint Complete assembly instruc tions included CABINET MANTEL with full...

Page 31: ...D 1349 Adams Street Bowling Green KY 42103 270 846 1199 1 800 654 8534 Fax 1 800 846 0090 franktalk aol com Master Parts Dist 1251 Mound Ave NW Grand Rapids MI 49504 616 791 0505 1 800 446 1446 Fax 61...

Page 32: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Reviews: