background image

108319-01B

4

For more information, visit www.desatech.com

For more information, visit www.desatech.com

4.

Attach green ground wire from power cord to blower housing
using screw provided (see Figure 9). Tighten screws securely.

5.

Place the blower against the lower rear wall of the firebox outer
wrapper with the exhaust port directed upward. Align the holes
in top mounting tabs of blower with holes in wall of wrapper
(see Figure 9). Using 2 screws provided, mount blower and
tighten screws securely.

6.

Be certain that all wire terminals are securely attached to ter-
minals on blower motor and that the screw retaining the green
ground wire is tight.

7.

Locate the plastic hole plug installed in the 3/8" diameter open-
ing in the lower right side of the firebox front panel (see Fig-
ure 10). Remove the plastic plug and discard.

INSTALLING BLOWER
ACCESSORY IN 36" OR 42"
FIREBOX

Continued

8.

Place speed control against inner wall of front panel, pushing
the plastic control shaft forward through the opening.

9.

While supporting speed control, secure control shaft with lock
nut by pushing and turning lock nut with pliers clockwise un-
til it is tight against front panel. Place control knob provided
on shaft (see Figure 11).

10. Turn on power to duplex outlet if previously turned off per the

warning in column 2, page 3.

11. Plug in blower power cord.

a. If your firebox is installed as a freestanding unit with an

accessory mantel, determine whether the power cord will
exit the left side or the right side of the firebox. Install 1 plas-
tic bushing provided into the 1 

1

/

2

" hole in the floor support on

the exit side. Install the second plastic bushing provided into
the 1

1

/

2

" hole in the outer casing through which the power

cord will exit (see Figures 10 and 12). Route power cord
through both plastic bushings and plug the power cord into a
wall receptacle near the firebox.

Figure 9 - Mounting Blower to Firebox

Blower

Screws

Top Mounting
Tab

Exhaust Port

Lower Rear Wall of
Firebox  Wrapper

Screw

Figure 10 - Installing Plastic Bushing for Power Cord

1

/

2

" Hole

Plastic
Bushing

Plastic
Hole Plug

Figure 11 - Attaching Speed Control to Firebox

Speed Control

Control Shaft

Locknut

Control Knob

Va

ria

ble

Fa

n S

wi

tch

 

W

hit

e

W

hit

e

Bla

ck

Gr

ee

n

On

11

0/1

15

 

V.

A.

C.

Blo

we

r

Mo

to

r

Bla

ck

Bla

ck

Bla

ck

Of

f

Figure 12 - Location of Wiring Diagram Decal

Wiring Diagram Decal 12"
in Front of Blower

Floor
Supports

1

/

2

" Hole

INSTALLING BLOWER ACCESSORY IN 36" OR 42" FIREBOX

Summary of Contents for Ga3750a

Page 1: ...r specific applications and additional instructions WARNING ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle For Use With Fireboxes NL FB32C NL FB36C FB42C NL UV32C CGFB32C and CGFB36C Series Vent Free Fireplaces VSGF28 VYGF33 VTGF33 ...

Page 2: ...ground wire is tight 6 Locate the plastic hole plug installed in the 3 8 diameter open ing in the lower right side of the firebox front panel see Fig ure 2 Remove the plastic plug and discard 7 Place speed control against inner wall of front panel pushing the plastic control shaft forward through the opening see Figure 3 Figure 1 Removing Screws from Firebox Bottom 8 While supporting speed control...

Page 3: ... concrete firebrick floor from the firebox see Figure 5 Some model fireboxes require that you remove the side and rear panels first Follow the directions below to remove the side and rear fire brick panels for those fireboxes a Using a Phillips screwdriver remove the screw and retainer bracket at the top of the brick liner panel on the left side Care fully remove the left panel from the firebox se...

Page 4: ...st front panel Place control knob provided on shaft see Figure 11 10 Turn on power to duplex outlet if previously turned off per the warning in column 2 page 3 11 Plug in blower power cord a If your firebox is installed as a freestanding unit with an accessory mantel determine whether the power cord will exit the left side or the right side of the firebox Install 1 plas tic bushing provided into t...

Page 5: ...ght your gas appliance with the blower off After about 15 minutes turn the blower on to deliver heated air at the top louvers Theblowerfeaturesavariablecontrolwhichallowsyoutoselectthe speed you desire Note Periodically check the louvers of the firebox and remove any dust dirt or other obstructions INSTALLING BLOWER ACCESSORY IN MODEL SVFBC FREESTANDING STOVE NOTICE Shutoffgasheaterduringthefollow...

Page 6: ...touch the blower wheel while in operation Figure 16 Attaching Blower to Mounting Bracket Blower Mounting Bracket Screws Exhaust Port Ground Wire OPERATING THE BLOWER Lightyourgasappliancewiththebloweroff Afterabout15minutes turn theblowerontodeliverheatedairatthetoplouvers Theblowerfeatures a variable control which allows you to select the speed you desire INSTALLING BLOWER ACCESSORY IN 32 FIREPLA...

Page 7: ... an outlet is not installed in your fireplace you must install the GA3555 Outlet kit with cover in your fireplace which will sup ply a convenient 3 prong grounded electrical outlet for your blower Refertotheinstallationmanualprovidedwiththemodel GA3555 accessory for instructions on wiring the duplex outlet Note Aqualifiedinstallermustmakeallelectricalconnections CAUTION Never touch the blower whee...

Page 8: ...gas appliance with the blower off After about 15 minutes turn the blower on to deliver heated air at the top louvers Theblowerfeaturesavariablecontrolwhichallowsyoutoselectthe speed you desire Note Periodically check the louvers of the fire box and remove any dust dirt or other obstructions NOTICE Shut off gas supply and disconnect heater from gas supply Contact a qualified service person to do th...

Page 9: ...lower Assembly Green Ground Wire CAUTION Never touch the blower wheel while in operation WARNING Failure to position the parts in accor dance with supplied diagrams or failure to use only partsspecificallyapprovedwiththisheatermayresult in damage or personal injury WARNING A qualified service person must con nect fireplace to gas supply Follow all local codes INSTALLING BLOWER ACCESSORY IN FREESTA...

Page 10: ...t against the plate Place control knob provided onto shaft see Figure 25 9 Replace plate containing switches and tighten screws securely 10 Plug in blower power cord a If your fireplace system is installed as a freestanding unit with an accessory mantel determine whether the power cord will exit the left side or the right side of the firebox Install one plastic bushing provided into the 1 1 2 hole...

Page 11: ...ure to position the parts in accor dance with supplied diagrams or failure to use only partsspecificallyapprovedwiththisheatermayresult in damage or personal injury 13 Connect or reconnect gas supply following instructions given in the owner s manual supplied with your fireplace WARNING A qualified service person must con nect fireplace to gas supply Follow all local codes Figure 26 Installing Pla...

Page 12: ...n visit www desatech com For more information visit www desatech com 108319 01 REV B 09 03 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Technical Service Department 1 866 672 6040 www desatech com 108319 01 NOT A UPC ...