background image

13

104464

OWNER’S MANUAL

OPERATING
HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part
of the control system and any gas con-
trol which has been under water.

Figure 23 - Pilot

Figure 22- Control Knob and Ignitor
Button Location

1.

STOP! Read the safety information,
column 1.

2.

Make sure equipment shutoff valve
is fully open.

3.

Turn control knob clockwise 

Clockwise

to the OFF position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation, column 1. If you don’t
smell gas, go to the next step.

5.

Turn control knob counterclockwise

C-clockwise

 to the PILOT position.

Press in control knob for five (5) sec-
onds (see Figure 22).

Note:

 You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds or less. This will allow
air to bleed from the gas system.

6.

With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.

Note: 

If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure,
 page 14.

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be present.
Open a window to vent smell. This
will only last a few hours.

Control Knob

Ignitor Button

Thermocouple

Pilot Burner

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out when

released, contact a qualified service
person or gas supplier for repairs.

Note: 

If pilot goes out, repeat steps 3

through 7. This heater has a safety inter-
lock system. Wait one (1) minute for sys-
tem to reset before lighting pilot again.

8.

Turn control knob counterclockwise

C-clockwise

  to desired heating level. The

burners should light. Set control knob
to any heat level between HI and LO.

TO TURN OFF GAS

TO APPLIANCE

 CAUTION: Do not try to adjust

heating levels by using the equip-
ment shutoff valve.

Shutting Off Heater

Turn control knob clockwise 

Clockwise

 to

the OFF position.

Shutting Off Burners Only (pilot
stays lit)

Turn control knob clockwise 

Clockwise

 to

the PILOT position.

Continued

Summary of Contents for Comfort Glow SL30PT

Page 1: ...operational procedures For as sistance or additional information con sult a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from...

Page 2: ...ng could occur due to log curing and heater burning manufactur ing residues 9 To prevent the creation of soot follow the instructions in Cleaning and Main tenance page 15 10 Before using furniture pol...

Page 3: ...There is no heat loss out a vent or up a chimney Heat is generated by realistic dancingyellowflames Thisheater is designed for vent free operation State and local codes in some areas prohibit the use...

Page 4: ...ating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied to ar...

Page 5: ...ot include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr u...

Page 6: ...ir from Inside Building VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide t...

Page 7: ...d adjoining side and back walls Carefullyfollowtheinstructionsbelow This stove is a freestanding unit designed to set directly on the floor IMPORTANT You must maintain minimum wall and ceiling clearan...

Page 8: ...t to leg Thread bolt in tapped holes on stove body see Figure 8 and Figure 9 page 9 Figure 7 Removing Pallet Wood From The Bottom of The Stove Figure 8 Locating Threaded Holes for Stove Bottom Legs an...

Page 9: ...ot holes and into threaded hole in stove body see Fig ure 11 Use an adjustable wrench or a 12mm socket to fasten step bolt Tighten step bolt until snug Make sure door moves freely 11 Install door catc...

Page 10: ...t through heater base mounting hole and through stove bot tom Connect hex nut to bolt on under side of stove bottom The bolt hex head is for a 5 16 socket and the hex nuts are for a 3 8 socket If sock...

Page 11: ...quip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connec tion Purchase the optional CSA AGA de sign certifiedequipmentshutoffvalvefrom your dealer See Accessories pag...

Page 12: ...nob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 21 Apply mixture of liquid soap and wa ter to gas joints Bubbles forming show a leak 5...

Page 13: ...n 1 If you don t smell gas go to the next step 5 Turn control knob counterclockwise C clockwise to the PILOT position Press in control knob for five 5 sec onds see Figure 22 Note You may be running th...

Page 14: ...ESA International s technical service web site at www desatech com SERVICE HINTS When Gas Pressure Is Too Low pilot will not stay lit burners will have delayed ignition heater will not produce specifi...

Page 15: ...rner tube and pilot assembly clean and free of dustanddirt Tocleanthesepartswerecom mend using compressed air no greater than 30 PSI Your local computer store hard ware store or home center may carry...

Page 16: ...aged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Replace piezo ignitor 5 Replace pi...

Page 17: ...oved from line Have gas line checked by local pro pane LP gas company 3 Observe minimum installation clear ances see page 7 4 Clean burner see Cleaning and Mainte nance page 15 or replace burner orifi...

Page 18: ...e just after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This i...

Page 19: ...Ave NW Grand Rapids MI 49504 2672 616 791 0505 1 800 446 1446 Fax 616 791 8270 www nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO AR 816 842 3911 www washerparts com Ea...

Page 20: ...20 104464 VENT FREE PROPANE LP GAS STOVE HEATER ILLUSTRATED PARTS BREAKDOWN SL30PT 14 16 3 4 15 5 11 6 12 7 10 15 8 9 1 17 2 18 18 18 13...

Page 21: ...80 01 Burner 1 11 101329 22 Control Valve 1 12 104472 01 Bracket 1 13 099211 01 Screw 2 14 102445 01 Piezo Ignitor 1 15 099387 13 Pilot Tube 1 16 098271 07 Ignitor Cable 1 17 104286 01 ODS Pilot LP 1...

Page 22: ...22 104464 VENT FREE PROPANE LP GAS STOVE HEATER ILLUSTRATED PARTS BREAKDOWN CISC CISG 7 4 6 4 5 4 5 1 5 2 3 5 3 5 4 2 1R 1C 1L...

Page 23: ...1 Hardware Kit 1 5 1 Door Hinge Step Bolt With Shoulder 1 Per Unit 1 5 2 Door Catch Bolt M8 x 1 25 55mm Long With Two M8 Hex Nuts 1 Per Unit 1 5 3 Bottom Floor Bolts M6 x 1 25mm Long With Flat Washer...

Page 24: ...a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WAR...

Reviews: