background image

2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004

www.desatech.com

INTERNATIONAL

105684-01
Rev. C
09/00

LIMITED WARRANTY

VENT-FREE PROPANE/LP GAS PEDESTAL STOVE

DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first
purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
To make a claim under this warranty the Bill of Sale or cancelled check must be presented.

This warranty is extended only to the original retail purchaser. This warranty covers the cost of part(s) required to restore this heater to proper
operating condition and an allowance for labor when provided by a DESA Authorized Service Center. Warranty part(s) MUST be obtained
through authorized dealers of this product and/or DESA International who will provide original factory replacement parts. Failure to use
original factory replacement parts voids this warranty. The heater MUST be installed by a qualified installer in accordance with all local
codes and instructions furnished with the unit.

This warranty does not apply to parts that are not in original condition because of normal wear and tear, or parts that fail or become damaged
as a result of misuse, accidents, lack of proper maintenance or defects caused by improper installation. Travel, diagnostic cost, labor,
transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner.

TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT;
THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESSED WARRANTIES AND LIMITS THE DURATION
OF ANY AND ALL IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE TO TWO (2) YEARS ON ALL COMPONENTS FROM THE DATE OF FIRST PURCHASE; AND DESA
INTERNATIONAL’S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND DESA INTERNA-
TIONAL SHALL NOT BE LIABLE FOR ANY OTHER DAMAGES WHATSOEVER INCLUDING INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES.

Some states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of incidental or consequential
damages, so the above limitation on implied warranties, or exclusion or limitation on damages may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

For information about this warranty write:

KEEP THIS WARRANTY

Model

Serial No.

Date Purchased

Always specify model and serial numbers when communicating with the factory.

We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
We make no other warranty, expressed or implied.

WARRANTY INFORMATION

NOT A UPC

105684 01

Summary of Contents for Comfort Glow S26PT

Page 1: ...d service must be performed by a qualified installer service agency or the gas supplier WARNING Improperinstallation adjustment alteration service ormaintenancecancauseinjury orpropertydamage Refertot...

Page 2: ...ake sure heater screen is in place before running heater 8 This heater is designed to be smoke less If logs ever appear to smoke turn off heater and call a qualified service person Note During initial...

Page 3: ...move log set by cutting plastic ties 8 Carefully unwrap log 9 Check for any shipping damage If stove or log is damaged promptly in form dealer where you bought stove PRODUCT FEATURES SAFETY PILOT This...

Page 4: ...herearedoorlesspassagewaysorventila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombusti...

Page 5: ...iances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr ma...

Page 6: ...igure 2 Ventilation Air from Inside Building VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined spac...

Page 7: ...reater clearances from floor ceiling and adjoining side and back walls Carefullyfollowtheinstructionsbelow This stove is a freestanding unit designed to set directly on the floor IMPORTANT You must ma...

Page 8: ...ap in supply line as shown in Figure 7 Locate sediment trap where it is within reach for cleaning Install in piping system betweenfuelsupplyandheater Locatesedi ment trap where trapped matter is not l...

Page 9: ...nected fittings for leaks CAUTION Make sure exter nal regulator has been installed between propane LP supply and heater SeeguidelinesunderCon necting to Gas Supply page 8 Test Pressures Equal To or Le...

Page 10: ...connectpowercordwiresfromblower motor if connected see Figure 13 4 Disconnect green ground wire from blower housing if connected by re moving screw holding wire terminal see Figure 13 Figure 12 Removi...

Page 11: ...4 Using two screws provided in blower kit mount blower speed control hous ing to mounting tab in left side of lower control compartment see Figure 17 15 Checktomakesurethatthepowercordis completelycle...

Page 12: ...Figure 20 shows a correct pilot flame pat tern Figure21showsanincorrectpilotflame pattern Theincorrectpilotflameisnottouch ing the thermocouple This will cause the thermocouple to cool When the thermo...

Page 13: ...cleanandfreeofdust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Yourlocalcomputerstore hardwarestore or home center may carry compressed air in a can You can...

Page 14: ...ntrol valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is l...

Page 15: ...nute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Observe minimum installation clearances see pages 7 through 9 4 Clean burner see Cleaning...

Page 16: ...er produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion Burner flame is excessively large and is very near or touc...

Page 17: ...tove 24 x 27 1 4 x 17 1 4 Carton 22 x 31 x 31 1 2 Weight pounds Stove 66 lbs Shipping 80 lbs For purposes of input adjustment Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553...

Page 18: ...18 105684 VENT FREE PROPANE LP PEDESTAL STOVE For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN S26PT 5 7 6 9 4 10 3 2 1 13 14 12 11 10 8...

Page 19: ...6039 01 Log Set 1 2 104286 01 ODS Pilot LP 1 3 098249 01 ODS Nut 2 4 105973 01 Burner Outlet Tube 1 5 105737 02 Injector Holder 1 6 102843 01 Burner Clip 1 7 099056 28 Burner Orifice Injector 1 8 1013...

Page 20: ...20 105684 VENT FREE PROPANE LP PEDESTAL STOVE For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN S26PT 1 4 13 3 2 14 7 16 15 11 18 10 5 6 9 8 17 12...

Page 21: ...10 105661 01 Firebox Top Assembly 1 11 105970 01 Screen Assembly 1 12 101382 01 Valve Bracket 1 13 105672 01 Brass Trim Bottom 1 14 105673 01 Brass Trim Firebox 1 15 106754 01 Knob 1 16 105971 01 Door...

Page 22: ...arts Central see page 17 If they can t supply original replacement part s call DESA International s Parts Department at 1 800 972 7879 for referral information WhencallingDESAInternational haveready m...

Page 23: ..._________________________________________ _______________________________________________________________________________________________ ______________________________________________________________...

Page 24: ...ts caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE F...