background image

8

104888

UNVENTED PROPANE/LP GAS FIREPLACE

LFP33PR

Figure 9 - Installing Cabinet Mantel

INSTALLATION
CLEARANCES

 WARNING: Maintain the mini-

mum clearances. If you can, pro-
vide greater clearances from
floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This
will ensure safe installation.

Minimum Wall and Ceiling
Clearances (see Figure 7)

A. Clearances from the side of the fire-

place opening to any combustible wall
should not be less than 16 inches for a
cabinet mantel or 12 inches for a cor-
ner installation.

B. Clearances from the top of the fireplace

opening to the ceiling should not be less
than 42 inches.

CONVENTIONAL FIREPLACE
INSTALLATION

Conventional installation of this fireplace
involves installing fireplace along with the
corner, face, or cabinet mantel with hearth
base accessories against a wall in your home.
Follow the instructions below to install the
fireplace in this manner.

Note: 

The instructions below show installa-

tion using the cabinet mantel and hearth
base accessories (see Accessories on pages
24 and 25). The hearth base accessory shown
is optional for this installation. You can
install fireplace and cabinet mantel directly
on the floor. The corner mantel accessory
cannot be installed with hearth bases. You
must install corner and face mantel directly
on the floor.

1.

Assemble cabinet mantel, hearth base,
and trim accessories. Assembly instruc-
tions are included with each accessory.

2.

When installing blower, install a prop-
erly grounded, 120 volt three-prong
electrical outlet at fireplace location if
an outlet is not there. If possible, lo-
cate outlet so cabinet mantel will cover
it when installed (see Figure 8).

3.

Install gas piping to fireplace location.
This installation includes an approved
flexible gas line (if allowed by local
codes) after the manual shutoff valve.
The flexible gas line must be the last
item installed on the gas piping. See In-
stalling Gas Piping to Fireplace Loca-
tion,
 page 10.

4.

Place hearth base accessory against
wall at installation location. Cut an ac-
cess hole in hearth top to run flexible
gas line to fireplace (see Figure 8).
Make sure to locate access hole so cabi-
net mantel will cover it when installed.

Note:

 You can secure base to floor us-

ing wood screws. Countersink screw
heads and putty over.

5.

Route flexible gas line through access
hole in hearth base.

6.

Center cabinet mantel on hearth base
(see Figure 9). Make sure mantel is
flush against wall.

Figure 7 - Minimum Clearance to Wall and
Ceiling

Figure 8 - Placing Hearth Base Accessory
Against Wall

Electrical
Outlet

Hearth
Base

Flexible
Gas Line

Gas
Line
Access
Hole

Cabinet
Mantel

INSTALLATION

Continued

42"

16"

Note: Clearances
are the same if
using optional
cabinet mantel or
built-in installation.

MINIMUM
CLEARANCE
Side Wall - 16"
Cabinet and
Face Mantel
Ceiling - 42"
Corner Mantel
Floor - 0"

7.

Break off nailing flanges (see Figure
10, page 9) with hammer or pliers.

8.

Place cardboard or other protective
material on top of hearth base. Care-
fully set fireplace on protective mate-
rial, with back of fireplace inside man-
tel opening.

9.

Attach flexible gas line to fireplace gas
regulator. See Connecting Fireplace to
Gas Supply,
 page 11.

10. If blower is installed, route blower elec-

trical cord through access holes in ei-
ther side of fireplace. 

Note:

 Bushing

may be moved if necessary. Plug elec-
trical cord into electrical outlet.

Summary of Contents for Comfort Glow LFP33PR

Page 1: ...la tion adjustment alteration ser vice ormaintenancecancause injury or property damage Re fer to this manual for correct installationandoperationalpro cedures For assistance or ad ditional information...

Page 2: ...ireplace 8 You must operate this fireplace with the fireplace screen and hood in place Make sure fireplace screen and hood are in place before running fireplace 9 This fireplace is designed to be smok...

Page 3: ...269 UNPACKING 1 With utility knife cut the carton all the way around above the staples on the bottom tray Lift the carton off the heater Remove packing Note The hood is located in the packing on the r...

Page 4: ...uate ventilation Unusually Tight Construction Theairthatleaksarounddoorsandwindows mayprovideenoughfreshairforcombustion and ventilation However in buildings of PRODUCT FEATURES OPERATION This vent fr...

Page 5: ..._ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amoun...

Page 6: ...Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the o...

Page 7: ...crews two adjust ing plates with set screws and two shims in the hardware packet 3 Align shim under adjusting plate as shown in Figure 5 4 Slide one end of adjusting plate shim in slot on mitered edge...

Page 8: ...le lo cate outlet so cabinet mantel will cover it when installed see Figure 8 3 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local co...

Page 9: ...t see Acces sories pages 24 and 25 3 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local codes after the manual shutoff valve The flex...

Page 10: ...rances for Built In Installation INSTALLING GAS PIPING TO FIREPLACE LOCATION Installation Items Needed Before installing fireplace make sure you have the items listed below external regulator supplied...

Page 11: ...lvefromyourdealer See Accessories pages 24 and 25 Installation must include a manual shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upst...

Page 12: ...ing system by ei ther using compressed air or opening propane LP supply tank valve 4 Check all joints of gas supply piping system Apply mixture of liquid soap and water to gas joints Bubbles form ing...

Page 13: ...sure the front of the middle log is resting on the tabs of the grate base and the cutout area is cen tered over the burner U bend 2 Locate pegs on the bottom of back log 2 Slide these pegs into the h...

Page 14: ...f re mote control unit following direction of arrow 2 Insert twoAAAbatteries following dia gram in battery housing area 3 Replace battery cover onto remote con trol unit Figure 31 Installing Battery i...

Page 15: ...he battery Place battery into the battery housing 3 Replace battery cover onto remote con trol unit Figure 36 Installing Battery in Hand Held Remote Control Unit Battery Cover 9 Volt Battery Terminal...

Page 16: ...or loss of life FOR YOUR SAFETY READ BEFORE LIGHTING OPERATING FIREPLACE WARNING Burnerswillcome on automatically within one minute when the selector switch is in the ON position after the pilot is li...

Page 17: ...ch in the OFF position MANUAL LIGHTING PROCEDURE Thermostat Control Operation The thermostat control setting on the remote control unit can be set to any comfort level between HI and LO The burners wi...

Page 18: ...heater and let cool Either remove blockage or replace burner Blocked burner flame holes will create soot CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the...

Page 19: ...ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace igni...

Page 20: ...ements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane gas company 3 Observe minimum inst...

Page 21: ...statement above 1 Improper log placement 2 Drafts or other air currents affecting flame pattern 3 Air holes at burner inlet blocked 4 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces a c...

Page 22: ...be low When Gas Quality Is Bad pilot will not stay lit burners will produce flames and soot heater will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad If so contact your loc...

Page 23: ...Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441...

Page 24: ...ER BRASS TRIM Not Shown GMC36F Series Walnut Finished Birch Veneer GMC37U Series Unfinished Birch Veneer Ready to Stain or Paint Space saving corner mantels feature mold ings fluting and medallion Dim...

Page 25: ...CGHRCT SERIES Allows the gas log heater to be operated in a manually or thermostatically controlled mode Youcanturnthegaslogheateronand off without ever leaving the comfort of your easy chair BRASS TR...

Page 26: ...UNVENTED PROPANE LP GAS FIREPLACE LFP33PR ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL LFP33PR 20 O F F P I L O T O N H I L O 11 15 29 10 9 7 6 5 1 2 4 3 8 12 7 17 16 28 18 19 24 14 13 19 23 22 26...

Page 27: ...Clip 1 10 099056 19 Burner Orifice Injector 1 11 102772 01 Burner 2 12 M11084 38 Screw 8 x 38 2 13 104236 01CK Painted Base Assy 1 14 M12461 26 Screw 10 x 32 4 15 104238 01CK Firebox Bottom 1 16 10328...

Page 28: ...28 104888 UNVENTED PROPANE LP GAS FIREPLACE LFP33PR 1 2 3 4 15 10 11 9 18 6 17 12 16 16 16 7 8 16 16 5 14 16 13 13 13 ILLUSTRATED PARTS BREAKDOWN FIREPLACE LFP33PR...

Page 29: ...Cover 1 6 101784 01 Snap in Magnet 2 7 103411 01CK Louver Hood 1 8 101838 03CK Firebox Wrapper 1 9 103412 01CK Louver Door 1 10 101727 02 Screen Assembly 1 11 101348 01 Firebox Support 2 12 103207 01...

Page 30: ...elated to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL...