14

104324

VENT-FREE PROPANE COMPACT FIREPLACE

 CGCF26PR

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information,
column 1.

2.

Make sure manual shutoff valve is
fully open.

3.

Set remote selector switch in the OFF
position.

 WARNING:

• If fireplace has glass doors,

never operate this heater with
glass doors closed. If you op-
erate heater with doors closed,
heat buildup inside fireplace
will cause glass to burst. Also
if fireplace opening has vents
at the bottom, you must open
the vents before operating
heater.

• You must operate this heater

with a fireplace screen in place.
Make sure fireplace screen is
closed before running heater.

 WARNING: Burners will come

on automatically within one
minute when the remote selector
switch is in the ON position after
the pilot is lit.

 CAUTION: Do not try to adjust

heating levels by using the
manual shutoff valve.

O

F

F

PIL

OT

O

N

LO

IH

REMOTE
OFF
ON

Control Knob

Ignitor Button

 Selector
Switch in
OFF Position

Flame Adjustment Knob

Figure 24 - Control Knob and Ignitor Button Location

Figure 25 - Pilot

Ignitor
Electrode

Pilot Burner

 WARNING: Make sure the

remote selector switch is in the
OFF position when you are away
from home for long periods of
time. Heater will come on auto-
matically with remote selector
switch in the ON position.

4.

Press in and turn control knob clock-
wise 

  to the OFF position.

5.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation, column 1. If you don’t
smell gas, go to the next step.

6.

Press in and turn control knob coun-
terclockwise  

  to the PILOT

position. Press in control knob for
five (5) seconds (see above).

Note:

 You may be running this

heater for the first time after hook-

ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds or more. This will al-
low air to bleed from the gas system.

7.

With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.

Note:

 If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure
 on page 15.

8.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out

when released, contact a qualified
service person or gas supplier for
repairs.

Note:

 If pilot goes out, repeat steps

4 through 8.

9.

Slightly push in and turn control
knob counterclockwise 

 to the

ON position.

10. Wait one minute and switch remote

selector switch to the ON position to
light burner.

11. Set flame adjustment knob to any

level between HI and LO.

OPERATING
FIREPLACE

FOR YOUR

SAFETY READ

BEFORE LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

Summary of Contents for Comfort Glow GCF26PR

Page 1: ...tstoreorusegasolineorotherflammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch d...

Page 2: ...oting Do not add lava rock around base Rock and debris could fall into the control area of fireplace 8 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is...

Page 3: ...2 Remove all protective packaging ap plied to fireplace for shipment 3 Make sure your fireplace includes one hardware packet and one remote con trol packet which includes batteries 4 Checkfireplacefor...

Page 4: ...sup port see Figure 2 The log should fit flat against top of burner support Place two 10 one inch long screws through burner support into the log and tighten Place branches on branch support see Figu...

Page 5: ...ntila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecombustionandven tilation air Read the...

Page 6: ...vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used ___________ B...

Page 7: ...igure 4 Ventilation Air from Inside Building Shown with Optional Mantel VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to a...

Page 8: ...6 inches from the front top or sides of the fireplace as a fireplace insert in high traffic areas in windy or drafty areas IMPORTANT Vent freefireplacesaddmois ture to the air Although this is benefic...

Page 9: ...connect blower to electrical source Option one Route blower electrical cord through side or rear access door of fireplace Plug electrical cord into electrical outlet 1 Frame in rough opening Use dime...

Page 10: ...irebox assembly Blower accessory should be installed if it is being used see Accesso ries page 21 1 Unscrew four brass screws that attach top louver to fireplace Remove louvre from fireplace and set a...

Page 11: ...male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged fireplace valves Installsedimenttrapinsupplylineasshown in Figure 17 Locate sediment t...

Page 12: ...ovided to allow accessibility fromthefireplace seeFigure19 The flexible gas supply line con nection to the manual shutoff valve should be accessible Branch Support Screen Screen Shipping Screw Shoulde...

Page 13: ...ect all leaks at once 6 Light fireplace see Operating Fire place pages 14 and 15 Check all other internal joints for leaks 7 Turn off fireplace see To Turn Off Gas to Appliance page 15 8 Replace front...

Page 14: ...itor button This will light pilot The pilot is attached to the front burner If needed keep press ing ignitor button until pilot lights Note If pilot does not stay lit con tact a qualified service pers...

Page 15: ...2 Select the MANUAL or AUTO but ton on the hand held remote control unit In MANUAL mode turn burners on or off by pressing the ON or OFF buttons on the hand held re mote control unit InAUTO mode the r...

Page 16: ...nal replacement part s callDESAInternational sTechnical Service Department at 1 800 323 5190 for referral information When calling DESA International have ready your name your address model number of...

Page 17: ...ODS pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep...

Page 18: ...r a few hours of operation 1 Refer to Air for Combustion and Venti lation requirements page 5 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from...

Page 19: ...st after burner is lit or shut off Heater produces unwanted odors Heater shuts off in use ODS operates Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 This is co...

Page 20: ...1348 Dixwell Avenue Hamden CT 06514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 Par...

Page 21: ...mantel andhearthbasecornerdesignfeaturesclean classic lines Available in a walnut finish or an unfinished hardwood ready to stain or paint Complete assembly instructions in cluded Three sided brass tr...

Page 22: ...GCF26PR ILLUSTRATED PARTS BREAKDOWN CGCF26PR 11 11 AU TO MA N OF F ST AT US ON LO HI TE MP 29 30 38 38 7 35 26 36 10 40 40 7 24 1 2 8 15 6 21 31 32 13 18 22 5 27 20 19 16 28 1 28 2 23 39 14 25 33 34 1...

Page 23: ...Base 1 16 102649 02CJ Branch Support 1 17 097159 04 Piezo 1 18 099387 13 Pilot Tube 1 19 098271 07 Ignitor Cable 1 20 098251 03 Injector 1 21 098250 01 Injector Holder 1 22 098249 01 Nut M5 6 23 1037...

Page 24: ...caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective fireplace will be the responsibility of the owner TO THE F...

Reviews: