background image

Summary of Contents for Comfort Glow CGP10R

Page 1: ...Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas sup...

Page 2: ...This heater needs fresh outside air ventilation to run properly This heater has an oxygen depletion sensor ODS pilot light safety system The ODS shuts down the heater if not enough fresh air is avail...

Page 3: ...r space and provide adequate ventilation Unusually Tight Construction The air that leaks around doors and win dows may provide enough fresh air for combustion and ventilation However in buildings of u...

Page 4: ...r Vented gas heater Btu Hr Gas fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Example Gas water heater 40 000 Btu Hr Vent free heater 10 000 Btu Hr Total 50 000 Btu Hr Do not include d...

Page 5: ...ion for required size of ventilation grills or ducts WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliance...

Page 6: ...a recreational vehicle where curtains furniture clothing or other flammable objects are less than 36 inches from the front top or sides of the heater as a fireplace insert in high traffic areas in win...

Page 7: ...onry drill at least 1 1 4 deep 2 Fold wall anchor see Figure 6 3 Insert wall anchor wings first into hole Tap anchor flush to wall Figure 6 Folding Anchor 4 For thin walls 1 2 or less insert red key i...

Page 8: ...ting Down CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe 3 8 diameter or greater to allow proper gas volume...

Page 9: ...s forming show a leak 5 Correct all leaks at once Test Pressures Equal To or Less Than 1 2 PSIG 1 Close manual shutoff valve see Figure 14 2 Pressurize supply piping system by either using compressed...

Page 10: ...ve 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information If you don t smell gas go to the next step 5 Press in control kno...

Page 11: ...me pattern often PILOT FLAME PATTERN Figure 19 shows a correct pilot flame pat tern Figure 20 shows an incorrect pilot flame pattern The incorrect pilot flame is not touching the thermocouple This wil...

Page 12: ...OT position there is no spark at ODS pilot 1 Ignitor electrode positioned wrong 1 Replace ignitor 2 Ignitor electrode broken 2 Replace ignitor 3 lgnitorelectrodenotconnectedtoignitor 3 Reconnect ignit...

Page 13: ...t gas pressure is too low 1 Clean burner orifice s see Cleaning and Maintenance page 15 or replace burner orifice s 2 Replace burner orifice s 3 Contact local propane LP gas company Delayed ignition o...

Page 14: ...Air for Combustion and Ventilation requirements page 3 2 Contact local propane LP gas company 3 Clean ODS pilot see Cleaning and Maintenance page 15 GasodorevenwhencontrolknobisinOFF 1 Gasleak SeeWarn...

Page 15: ...ESA International s Parts Department at 1 800 972 7879 for referral information When calling DESA International have ready model number of your heater the replacement part number SERVICE PUBLICATIONS...

Page 16: ...GAS RESIDENTIAL HEATERS ILLUSTRATED PARTS BREAKDOWN CGP1 OR CGP10RL 2 1 HEATER EXPLODED VIEW 3 7 2 ODS PILOT i 24 15 11 9 16 1o3548...

Page 17: ...01 102445 01 098271 03 QTY Screw 10 x3 8 2 Front Panel Assembly Earth Tone CGP10R 1 Front Panel Assembly Ivory CGP10RL 1 Grill Guard 1 Removable Speed Clip 2 Reflector Assembly 1 Screw Hex 8 x 1 4 10...

Page 18: ...GAS RESIDENTIAL HEATERS...

Page 19: ...NOTES 1_ 19 OWNER S MANUAL...

Page 20: ...This warranty does not apply to parts that are not in original condition because of normal wear and tear or partsthat fall or become damaged asa result of misuse accideats lack of proper maintenance...

Reviews: